Effective arrangement of separated transmit-only/receive-only RF coil for improvement of B1 homogeneity at 7 Tesla

被引:3
|
作者
Im, Geun Ho [1 ]
Seo, Jeong-Hoon [1 ]
Kim, Kyoung-Nam [1 ]
Heo, Phil [2 ,3 ]
Chung, Julius Juhyun [2 ,3 ]
Jang, Moon-Sun [2 ,3 ]
Lee, Jung Hee [2 ,3 ]
Kim, Jae-Hun [2 ,3 ]
Kim, Sun I. [4 ]
机构
[1] Samsung Biomed Res Inst, Ctr Mol & Cellular Imaging, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Radiol, Samsung Med Ctr, Seoul 135710, South Korea
[3] Sungkyunkwan Univ, Samsung Adv Inst Hlth Sci & Technol, Seoul 135710, South Korea
[4] Hanyang Univ, Dept Biomed Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
MRI (Magnetic Resonance Imaging); RF (Radiofrequency) coil; TORO (Transmit-only/receive-only); Homogeneity; 7; Tesla; MACROSCOPIC SUSCEPTIBILITY; LINE ARRAY; MRI; PULSE; HEAD;
D O I
10.3938/jkps.65.616
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
This article presents an effective arrangement with shifted transmit (Tx)-only and receive (Rx)-only (TORO) radiofrequency (RF) coils in a single-channel surface coil for improving the magnetic flux (B (1)) homogeneity in an ultra-high field (UHF) magnetic resonance imaging (MRI) scanner. The proposed new methodology for the coil arrangement using the shifted TORO RF coils was demonstrated for coils with 50-mm, 100-mm, and 150-mm-square surfaces and the results were compared to those for general Tx/Rx surface coils with the same dimensions. The computational analysis indicated that a homogeneous B-1 field was achieved when the Rx-only coil was shifted in the two-dimensional xy-plane away from the Tx-only coils. Because the proposed coil configuration provides a unique opportunity for increasing the B (1) homogeneity, this feature is likely to increase the feasibility via new coil arrangements of UHF surface design and fabrication.
引用
收藏
页码:616 / 624
页数:9
相关论文
共 16 条
  • [1] Effective arrangement of separated transmit-only/receive-only RF coil for improvement of B1 homogeneity at 7 Tesla
    Geun Ho Im
    Jeong-Hoon Seo
    Kyoung-Nam Kim
    Phil Heo
    Julius Juhyun Chung
    Moon-Sun Jang
    Jung Hee Lee
    Jae-Hun Kim
    Sun I. Kim
    Journal of the Korean Physical Society, 2014, 65 : 616 - 624
  • [2] Customized Radiofrequency Phased-Array Coil Combining Transmit-Only, Receive-Only, and Transmit/Receive Coils for Magnetic Resonance Imaging of Visual Cortex at 7 Tesla
    Kim, Hyeong-Seop
    Song, Byung-Pan
    Kim, Royoung
    Choi, Woo-Chul
    Kim, Donghyuk
    Shim, Won Mok
    Kim, Kyoung-Nam
    Lee, Seung-Kyun
    IEEE ACCESS, 2022, 10 : 42083 - 42093
  • [3] Unshielded asymmetric transmit-only and endorectal receive-only radiofrequency coil for 23Na MRI of the prostate at 3 tesla
    Farag, Adam
    Peterson, Justin Charles
    Szekeres, Trevor
    Bauman, Glenn
    Chin, Joseph
    Romagnoli, Cesare
    Bartha, Robert
    Scholl, Timothy J.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 436 - 445
  • [4] A transmit-only/receive-only (TORO) RF system for high-field MRI/MRS applications
    Barberi, EA
    Gati, JS
    Rutt, BK
    Menon, RS
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (02) : 284 - 289
  • [5] Transmit-only/receive-only radiofrequency coil configuration for hyperpolarized 129Xe MRI of rat lungs
    Doganay, Ozkan
    Thind, Kundan
    Wade, Trevor
    Ouriadov, Alexei
    Santyr, Giles E.
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2015, 45 (03) : 115 - 124
  • [6] Magnetic field sensitivity at 7-T using dual-helmholtz transmit-only coil and 12-channel receive-only bended coil
    Kim, Kyoung-Nam
    Ryu, Yeunchul
    Seo, Jeung-Hoon
    Kim, Young-Bo
    SCANNING, 2016, 38 (06) : 515 - 524
  • [7] Automated Tuning and Matching of a 16-Channel TEM Transmit-Only Array used in Conjunction with a 32-Channel Receive-Only Loop Array for MR Cardiac Imaging at 7 Tesla.
    Snyder, Carl J.
    DelaBarre, Lance
    Vaughan, J. Thomas
    2013 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (IMS), 2013,
  • [8] Effects of Receive-Only Inserts on Specific Absorption Rate, B1+ Field, and Tx Coil Performance
    Krishnamurthy, Narayanan
    Zhao, Tiejun
    Ibrahim, Tamer S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (02) : 475 - 484
  • [9] Whole-brain imaging with receive-only multichannel top-hat dipole antenna RF coil at 7 T MRI
    Kumar, Suchit
    Yoon, Jun-Sik
    Kim, Jong-Min
    Lee, Chulhyun
    Oh, Chang-Hyun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 80 (09) : 920 - 927
  • [10] Whole-brain imaging with receive-only multichannel top-hat dipole antenna RF coil at 7 T MRI
    Suchit Kumar
    Jun-Sik Yoon
    Jong-Min Kim
    Chulhyun Lee
    Chang-Hyun Oh
    Journal of the Korean Physical Society, 2022, 80 : 920 - 927