Clinical Application of Atlantoaxial Pedicle Screw Placement Assisted by a Modified 3D-Printed Navigation Template

被引:10
|
作者
Pu, Xingwei [1 ]
Luo, Chunshan [1 ]
Lu, Tinsheng [1 ]
Yao, Shudan [1 ]
Chen, Qiling [1 ]
机构
[1] Guizhou Orthoped Hosp, Dept Spinal Surg, Guiyang 550002, Guizhou, Peoples R China
关键词
Atlantoaxial; Improvement; Navigation Template; 3D Print; Pedicle Screw; ACCURACY;
D O I
10.6061/clinics/2018/e259
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: To investigate the primary clinical value of atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. METHODS: We retrospectively analyzed the cases of 17 patients treated from June 2015 to September 2016 with atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template. All procedures were performed prior to surgery, including thin-slice CT scanning, medical image sampling and computerized 3D modeling of the atlantoaxial joint, optimal pedicle screw trajectory determination, and anatomical trait acquisition for the atlantoaxial pedicle, spinous process of the axis, vertebral lamina and posterior lateral mass, and design of a reverse template. During surgery, a navigation template was tightly attached to the atlantoaxial joint to assist in pedicle screw placement. Surgeons subsequently used an electric drill to remove the template through a guide channel and then placed the atlantoaxial pedicle screw. Observed indexes included the VAS score, JOA improvement rate, surgery duration, and blood loss. RESULTS: Surgery was successful in all 17 patients, with an average operation duration of 106 +/- 25 min and an average blood loss of 220 +/- 125 ml. Three days postoperatively, the VAS score decreased from 6.42 +/- 2.21 to 3.15 +/- 1.26. Six months postoperatively, the score decreased to 2.05 +/- 1.56. The postoperative JOA score increased significantly from 7.68 +/- 2.51 to 11.65 +/- 2.72 3 d after surgery and to 13.65 +/- 2.57 after 6 months. Sixtyeight pedicle screws were inserted successfully, with 34 in the atlas and 34 in the axis. According to the Kawaguchi standard, 66 screws were in grade 0 (97.06%), and 2 were in grade 1 (2.94%). The pre- and postoperative transverse and sagittal screw angles showed no significant differences. CONCLUSIONS: Atlantoaxial pedicle screw placement assisted by a modified 3D-printed navigation template is worth recommending due to the improved accuracy in screw placement, improved patient safety and beneficial clinical effects.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] 3D-printed template-assisted reduction of long bone fractures
    Liodakis, E.
    Bruns, N.
    Macke, C.
    Krettek, C.
    Omar, M.
    UNFALLCHIRURG, 2019, 122 (04): : 286 - 292
  • [42] A novel screw view model of 3D navigation for upper cervical pedicle screw placement A case report
    Zhao, Jianwu
    Yang, Lili
    Zheng, Shuang
    Qu, Yang
    Zhang, Xiwen
    Kang, Mingyang
    Dong, Rongpeng
    Zhao, Xin
    Yu, Tong
    MEDICINE, 2019, 98 (19)
  • [43] Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template
    Zhao, Yonghui
    Luo, Haotian
    Ma, Yulong
    Liang, Jinlong
    Han, Gonghai
    Xu, Yongqing
    Lu, Sheng
    WORLD NEUROSURGERY, 2021, 146 : E161 - E167
  • [44] Accuracy Assessment of Pedicle and Lateral Mass Screw Insertion Assisted by Customized 3D-Printed Drill Guides: A Human Cadaver Study
    Pijpker, Peter A. J.
    Kraeima, Joep
    Witjes, Max J. H.
    Oterdoom, D. L. Marinus
    Coppes, Maarten H.
    Groen, Rob J. M.
    Kuijlen, Jos M. A.
    OPERATIVE NEUROSURGERY, 2019, 16 (01) : 94 - 102
  • [45] Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine
    Guo, Fei
    Dai, Jianhao
    Zhang, Junxiang
    Ma, Yichuan
    Zhu, Guanghui
    Shen, Junjie
    Niu, Guoqi
    PLOS ONE, 2017, 12 (02):
  • [46] Comparison of the Accuracy and Safety of Pedicle Screw Placement in Thoracic Spine Between 3D Printed Navigation Templates and Free Hand Technique
    Kovalenko, R. A.
    Ptashnikov, D. A.
    Cherebillo, V. Yu
    Kashin, V. A.
    TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2020, 26 (03): : 49 - 60
  • [47] 3D-Printed Ventriculostomy Placement Simulator
    Savastano, Luis
    Tai, Bruce
    Rooney, Deborah
    Shih, Albert
    Sagher, Oren
    JOURNAL OF NEUROSURGERY, 2015, 123 (02) : A538 - A538
  • [48] Facet Violation With Percutaneous Pedicle Screw Placement: Impact of 3D Navigation and Facet Orientation
    Cong, Ting
    Sivaganesan, Ahilan
    Mikhail, Christopher M.
    Vaishnav, Avani S.
    Dowdell, James, III
    Barbera, Joseph
    Kumagai, Hiroshi
    Markowitz, Jonathan
    Sheha, Evan
    Qureshi, Sheeraz A.
    HSS JOURNAL, 2021, 17 (03) : 281 - 288
  • [49] Feasibility and improvement of a three-dimensional printed navigation template for modified cortical bone trajectory screw placement in the lumbar spine
    Shi, Wenjie
    Aini, Mijiti
    Dang, Limin
    Kahaer, Alafate
    Zhou, Zhihao
    Wang, Yixi
    Maimaiti, Abulikemu
    Wang, Shuiquan
    Guo, Hailong
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [50] Application of a 3D-Printed Navigation Mold in Puncture Drainage for Brainstem Hemorrhage
    Wang, Qingbo
    Guo, Wei
    Liu, Yongliang
    Shao, Wei
    Li, Meng
    Li, Zhenzhu
    Li, Chenglong
    Li, Zefu
    JOURNAL OF SURGICAL RESEARCH, 2020, 245 : 99 - 106