Na18F accumulates on the compressive side of peri-implant bone under immediate loading

被引:3
|
作者
Yamamoto, Miou [1 ]
Ogawa, Toru [1 ]
Yokoyama, Masayoshi [1 ]
Funaki, Yoshihito [2 ]
Shobara, Kenta [1 ]
Shibamoto, Aya [1 ]
Saenz, Juan Ramon Vanegas [1 ]
Sasaki, Keiichi [1 ]
机构
[1] Tohoku Univ, Grad Sch Dent, Div Adv Prosthet Dent, Aoba Ku, 4-1 Seiryo Machi, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Ctr Cyclotron & Radioisotope, Sendai, Miyagi, Japan
关键词
Bone metabolism; Peri-implant bone; (NaF)-F-18-PET; Immediate loading; Animal study; METABOLIC-ACTIVITY; DENTAL IMPLANTS; PET; SCINTIGRAPHY; RESOLUTION; ION;
D O I
10.1007/s10266-017-0327-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study aimed to examine the dynamic change in bone metabolism by immediate loading in several sites around implants using high-resolution (NaF)-F-18-PET scan. Two titanium implants ( 1.2 mm) were inserted parallel to each other in the right tibiae of Wistar rats (n = 4). The left tibia was set as control side. One day after insertion, closed coil springs of 4.0 N were attached to the expose superior portions of the implants to apply a continuous mechanical stress. The rats with fluorine-18 (F-18) ion (5 mCi/rat) intravenously injected were scanned by PET scanner at 4, 7, 14, 28 days after load application. Round region of interests (ROIs) were set around the distal implant of the right tibia (loaded side) and same site (control) of the left tibia. Furthermore, four rectangular ROIs were set at the superior and inferior parts of traction side (mesial) and opposite side (distal) of the distal implant. Longitudinal dynamic changes in bone metabolism were evaluated by examination of the accumulation count of F-18 ion at each ROI. The uptake values of ROIs (loaded side) initially increased until 7 days, and they gradually decreased from the peak level to the pre-loading level despite a static force being applied to the implants. In cancellous bone, the uptake values at the superior part of traction side and inferior part of opposite side showed significantly high value compared with those at other parts. In conclusion, immediate loading to the implant initially enhanced bone metabolism around it, especially at the part with compressive stress. Peri-implant bone metabolism varies according to different loading conditions.
引用
收藏
页码:232 / 237
页数:6
相关论文
共 50 条
  • [21] Peri-implant bone changes in response to progressive osseous loading.
    Appleton, RS
    Nummikoski, PV
    Pigno, MA
    Bell, FA
    Cronin, RJ
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 3191 - 3191
  • [22] Numerical simulation of the effect of time-to-loading on peri-implant bone
    Akca, Kivanc
    Eer, Atilim
    Canay, Senay
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (01) : 7 - 13
  • [23] Associated lesions of peri-implant mucosa in immediate versus delayed loading of dental implants
    Iliescu, Alexandru Andrei
    Zurac, Sabina Andrada
    Nicolae, Vasile
    Iliescu, Mihaela Georgiana
    Perlea, Paula
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2017, 58 (02): : 487 - 492
  • [24] Relationship of Three-Dimensional Bone-to-Implant Contact to Primary Implant Stability and Peri-implant Bone Strain in Immediate Loading: Microcomputed Tomographic and In Vitro Analyses
    Hsu, Jui-Ting
    Huang, Heng-Li
    Chang, Chih-Han
    Tsai, Ming-Tzu
    Hung, Wei-Ching
    Fuh, Lih-Jyh
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 367 - 374
  • [25] Assessment of Peri-Implant Tissue Health and Marginal Bone Loss in Immediate Versus Delayed Implant Placement
    Karni, Prashant A.
    Kasarla, Himaja
    Konwar, Annesha Koinyaki
    Junaid, Irfa
    Mansoor, Manawar Ahmad
    Lone, Sumedh
    Kadam, Pooja
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2582 - S2584
  • [26] Discontinuation of simvastatin leads to a rebound phenomenon and results in immediate peri-implant bone loss
    Li, Xianqi
    Wu, Feng
    Zhang, Yiming
    Yang, Jing
    Shinohara, Atsushi
    Kagami, Hideaki
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2016, 2 (01): : 65 - 72
  • [27] Effect of intermittent loading and surface roughness on peri-implant bone formation in a bone chamber model
    Duyck, Joke
    Slaets, Elke
    Sasaguri, Kenichi
    Vandamme, Katleen
    Naert, Ignace
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (11) : 998 - 1006
  • [28] The Influence of Bone Loss on Peri-implant Bending Strain Under Overdentures
    Nguyen Quan Pham
    Gonda, Tomoya
    Takahashi, Toshihito
    Maeda, Yoshinobu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (04) : 900 - 906
  • [29] Effects of Immediate and Delayed Loading on Peri-Implant Trabecular Structures: A Cone Beam CT Evaluation
    Huang, Yan
    Van Dessel, Jeroen
    Liang, Xin
    Depypere, Maarten
    Zhong, Weijian
    Ma, Guowu
    Lambrichts, Ivo
    Maes, Frederik
    Jacobs, Reinhilde
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (06) : 873 - 883
  • [30] Changes in the fractal dimension of peri-implant trabecular bone after loading: a retrospective study
    Mu, Teh-Jing
    Lee, Dong-Won
    Park, Kwang-Ho
    Moon, Ik-Sang
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (05): : 209 - 214