Reproducibility of an intraoral scanner: A comparison between in-vivo and ex-vivo scans

被引:43
|
作者
Sun, LiJun [1 ]
Lee, Jin-Sol [1 ]
Choo, Hyun-Hee [1 ]
Hwang, Hyeon-Shik [2 ]
Lee, Kyung-Min [2 ]
机构
[1] Chonnam Natl Univ, Sch Dent, Gwangju, South Korea
[2] Chonnam Natl Univ, Sch Dent, Dept Orthodont, 33 Yongbong Ro, Gwangju 61186, South Korea
基金
新加坡国家研究基金会;
关键词
DENTAL IMPRESSIONS; DIGITAL MODELS; RELIABILITY; ACCURACY; VALIDITY;
D O I
10.1016/j.ajodo.2017.09.022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this study was to assess the reproducibility of in-vivo and ex-vivo scans using an intraoral scanner. Methods: Twenty adults with no missing teeth except for third molars were included in the study. Alginate impressions were taken, and plaster models were made from the impressions. Each subject underwent full-arch intraoral scanning twice with a TRIOS scanner (3Shape, Copenhagen, Denmark) at an interval of 2 weeks, and, the plaster models were scanned at the same interval with the same scanner. The first images of each scan were superimposed on the second scanned images using surface-based registration. In each case, the differences between the 2 scanned images were evaluated with color mapping. The reproducibility between the in-vivo and ex-vivo scans was compared using independent t tests and Bland-Altman analysis. Results: The discrepancies between the first and second images were greater in the posterior than in the anterior regions for both the in-vivo and ex-vivo scans. Average surface differences between the first and second images were greater for the in-vivo scans (0.04 mm) than for the ex-vivo scans (0.02 mm). The Bland-Altman plots showed that the reproducibility of both scans was within the limits of agreement. Conclusions: The reproducibility of in-vivo scanning was comparable with ex-vivo scanning, although it showed a slight difference (0.02 mm) compared with ex-vivo scanning.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 50 条
  • [41] EFFECT OF FIBRIN SEALANT COMPONENTS ON BONDING STRENGTH - EX-VIVO AND IN-VIVO ANALYSIS
    BUSBY, SJ
    BUDDLE, M
    GERAGHTY, JA
    WALNER, DL
    TORIUMI, DM
    THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 819 - 819
  • [42] X-ray cell tracking: from ex-vivo to in-vivo experiments
    Astolfo, A.
    Schueltke, E.
    Menk, R. -H.
    Hall, C.
    Juurlink, B.
    Arfelli, F.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [43] Hyperspectral Imaging for In-Vivo/Ex-Vivo Tissue Analysis of Human Brain Cancer
    Leon, Raquel
    Gelado, Sofia H.
    Fabelo, Himar
    Ortega, Samuel
    Quintana, Laura
    Szolna, Adam
    Pineiro, Juan F.
    Balea-Fernandez, Francisco
    Morera, Jesus
    Clavo, Bernardino
    Callico, Gustavo M.
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [44] SEDDS of gliclazide: Preparation and characterization by in-vitro, ex-vivo and in-vivo techniques
    Nipun, Tanzina Sharmin
    Islam, S. M. Ashraful
    SAUDI PHARMACEUTICAL JOURNAL, 2014, 22 (04) : 343 - 348
  • [45] Sentinel node mapping in colon carcinoma: In-vivo versus ex-vivo approach
    Tuech, JJ
    Pessaux, P
    Di Fiore, F
    Nitu, V
    Lefebure, B
    Colson, A
    Michot, F
    EJSO, 2006, 32 (02): : 158 - 161
  • [46] Ex-Vivo and In-Vivo Assessment of Cyclamen europaeum Extract After Nasal Administration
    Fernandez-Campos, Francisco
    Clares, Beatriz
    Rodriguez-Lagunas, Maria J.
    Jauregui, Olga
    Casals, Isidre
    Calpena, Ana C.
    PHARMACEUTICS, 2019, 11 (09)
  • [47] A morphological and mechano-biological comparison between ascending thoracic aneurysms with bicuspid and tricuspid valves via in-vivo and ex-vivo investigation
    Vignali, E.
    Capellini, K.
    Celi, S.
    Losi, P.
    Vivoli, G.
    Cerone, E.
    Positano, V.
    Landini, L.
    Murzi, M.
    Berti, S.
    EUROPEAN HEART JOURNAL, 2017, 38 : 825 - 826
  • [48] VISCOSITY MATCHING POSITIVELY AFFECTS THE CORRELATION OF PRESSURE-VOLUME LOOPS BETWEEN IN-VIVO AND EX-VIVO MODELS
    Schinstock, Emma
    Kudlik, D'Anne
    Eggen, Michael
    Iaizzo, Paul A.
    PROCEEDINGS OF THE 2021 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2021), 2021,
  • [49] In-vivo metabolic tumour volume correlation with ex-vivo pathological volume in laryngeal SCC
    Patel, N.
    Tam, H. H.
    Sandison, A.
    Win, Z.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S262 - S262
  • [50] STUDIES ON THE THROMBOGENIC EFFECTS OF RECOMBINANT TISSUE FACTOR - IN-VIVO VERSUS EX-VIVO FINDINGS
    CALLAS, DD
    BACHER, P
    FAREED, J
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1995, 21 (02): : 166 - 176