Comparison of surface plasmon resonance devices for acoustic wave detection in liquid

被引:42
|
作者
Nuster, R. [1 ]
Paltauf, G.
Burgholzer, P.
机构
[1] Karl Franzens Univ Graz, Dept Phys, A-8010 Graz, Austria
[2] Upper Austrian Res, A-4020 Linz, Austria
关键词
D O I
10.1364/OE.15.006087
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Surface plasmon resonance (SPR) sensors represent a suitable method for broadband acoustic pulse detection. The reflectivity and phase of a p-polarized laser beam incident on an optical device under SPR conditions are strongly dependent on ambient conditions that are changed by an acoustic wave. Depending on the order of layers, SPR sensors can be arranged in the Kretschmann or in the Otto configuration acting as a pressure or as a displacement sensor. The aim of this study was to compare both configurations and to find linear and sensitive conditions for the application. Numerical calculations were carried out varying the layer dimensions and the angle of incidence. The results of the experimental investigation on both configurations confirm the working principle. (C) 2007 Optical Society of America
引用
收藏
页码:6087 / 6095
页数:9
相关论文
共 50 条
  • [31] ACOUSTIC-WAVE PROPAGATION IN SURFACE ACOUSTIC-WAVE DEVICES
    LERCH, R
    AEU-ARCHIV FUR ELEKTRONIK UND UBERTRAGUNGSTECHNIK-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 1990, 44 (04): : 317 - 327
  • [32] IMPROVING MANUFACTURABILITY OF BULK ACOUSTIC WAVE AND SURFACE ACOUSTIC WAVE DEVICES
    Mishin, Sergey
    2011 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS (SPAWDA), 2011, : 110 - 112
  • [33] Sensitivity comparison of surface plasmon resonance and plasmon-waveguide resonance biosensors
    Abbas, Abdennour
    Linman, Matthew J.
    Cheng, Quan
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (01) : 169 - 175
  • [34] Thickness and viscosity of organic thin films probed by combined surface acoustic Love wave and surface plasmon resonance
    Friedt, JM
    Francis, LA
    Ballandras, S
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1143 - 1146
  • [35] Surface acoustic wave based analytical system for the detection of liquid detergents
    Vivancos, Jose-Luis
    Racz, Zoltan
    Cole, Marina
    Gardner, Julian W.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 : 469 - 477
  • [36] Comparison of antibody immobilization strategies in detection of Vibrio cholerae by surface plasmon resonance
    Taheri, Ramezan Ali
    Rezayan, Ali Hossein
    Rahimi, Fereshteh
    Mohammadnejad, Javad
    Kamali, Mehdi
    BIOINTERPHASES, 2016, 11 (04)
  • [37] Comparison of the performance of flexural plate wave and surface acoustic wave devices as the detector in a gas chromatograph
    Black, JP
    Chen, B
    Quinn, R
    Madou, M
    White, RM
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 435 - 440
  • [38] Comparison of a carboxylated terthiophene surface with carboxymethylated dextran layer for surface plasmon resonance detection of progesterone
    Wang, Yijing
    Partridge, Ashton
    Wu, Yinqiu
    ANALYTICAL BIOCHEMISTRY, 2016, 508 : 46 - 49
  • [39] Comparative Study of Binding Constants from Love Wave Surface Acoustic Wave and Surface Plasmon Resonance Biosensors Using Kinetic Analysis
    Lee, Sangdae
    Kim, Yong-Il
    Kim, Ki-Bok
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (11) : 7319 - 7324
  • [40] Segmented wave analysis of surface plasmon resonance on curved surface
    Lee, Hyunwoong
    Kim, Donghyun
    INTERNATIONAL CONFERENCE ON NANO-BIO SENSING, IMAGING, AND SPECTROSCOPY 2017, 2017, 10324