A Case Study of a Ground-Source Heat Pump System in an East China Office Building

被引:0
|
作者
Li, Zhengrong [1 ]
Zhao, Mingming [1 ]
Yu, Sheng [1 ]
Li, Haozhu [1 ]
机构
[1] Tongji Univ, Sch Mech Engn, Shanghai 200092, Peoples R China
关键词
Ground-source heat pump; Seasonal energy efficiency;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
First, the performance of a ground-source heat pump system and a water source heat pump system in an office building in East China is tested. The temperature of supply and return water of the cooler, and that of supply and return air of indoor fan coil are obtained during the summer and winter. Then, based on the field measured data, the seasonal energy efficiency ratio is calculated and the performance of heat pump system in summer is compared with that in winter. Then, according to the conditions of the real building, the software Energy Plus is used to simulate the seasonal air-conditioning load to find out the time period during which the two heat pump system can satisfy cooling and heating load, then the optimal operation control strategy is discussed. Finally, the temperature along the underground supply water pipes is collected to calculate the heat diffusivity of these pipes in the earth using a method introduced by ASHRAE, which is aimed to give some advice on the ground-source heat pump system design in this district.
引用
收藏
页码:1586 / 1592
页数:7
相关论文
共 50 条
  • [21] Hybrid ground-source heat pump system with active air source regeneration
    Allaerts, K.
    Coomans, M.
    Salenbien, R.
    ENERGY CONVERSION AND MANAGEMENT, 2015, 90 : 230 - 237
  • [22] Theoretical study on the performance of an integrated ground-source heat pump system in a whole year
    Fan, Rui
    Jiang, Yiqiang
    Yao, Yang
    Ma, Zuiliang
    ENERGY, 2008, 33 (11) : 1671 - 1679
  • [23] Ground-source heat pump system research - Past, present, and future
    Spitler, JD
    HVAC&R RESEARCH, 2005, 11 (02): : 165 - 167
  • [24] An office building energy-saving design of ground source heat pump system
    Yu, Wei
    Zhu, Chunying
    Gao, Menghui
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3093 - 3096
  • [25] RESEARCH AND APPLICATION OF SOLAR-ASSISTED GROUND-SOURCE HEAT PUMP HYBRID SYSTEM IN CHINA
    Gong, Xue-Mei
    ENERGY AND MECHANICAL ENGINEERING, 2016, : 227 - 237
  • [26] Performance prediction of a hybrid solar ground-source heat pump system
    Wang, Enyu
    Fung, Alan S.
    Qi, Chengying
    Leong, Wey H.
    ENERGY AND BUILDINGS, 2012, 47 : 600 - 611
  • [27] Exergetic performance assessment of a ground-source heat pump drying system
    Kuzgunkaya, Ebru Hancioglu
    Hepbasli, Arif
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (08) : 760 - 777
  • [28] Comprehensive exergy analysis of a ground-source heat pump system for both building heating and cooling modes
    Bi, Yuehong
    Wang, Xinhong
    Liu, Yun
    Zhang, Hua
    Chen, Lingen
    APPLIED ENERGY, 2009, 86 (12) : 2560 - 2565
  • [29] The Ratio of Cumulating Cooling Load in Ground-source Heat Pump System
    Li, Na
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1825 - 1829
  • [30] Construction Technology and Economic Analysis of Ground-Source Heat Pump System
    Yuan, Zhiyang
    MATERIALS, MECHANICAL ENGINEERING AND MANUFACTURE, PTS 1-3, 2013, 268-270 : 978 - 982