High sensitivity neutron detector for Z

被引:10
|
作者
Ruggles, LE
Porter, JL
Simpson, WW
Vargas, MF
Zagar, DM
Hartke, R
Buersgens, F
Symes, DR
Ditmire, T
机构
[1] Sandia Natl Labs, Albuquerque, NM 87185 USA
[2] Univ Texas, Austin, TX 78712 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2004年 / 75卷 / 10期
关键词
D O I
10.1063/1.1789599
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have developed, calibrated, and tested a high sensitivity neutron detector that can be operated in the harsh x-ray bremsstrahlung environment that exists in experiments conducted on the 20 MA Z z-pinch facility located at Sandia National Laboratories in Albuquerque, New Mexico. The detector uses a scintillator coupled to a microchannel-plate photomultiplier tube detector and extensive x-ray shielding. (C) 2004 American Institute of Physics.
引用
收藏
页码:3595 / 3597
页数:3
相关论文
共 50 条
  • [21] Neutron sensitivity of the endcap RPC modules in Belle detector
    Abe, K
    Hoshi, Y
    Nagamine, T
    Neichi, K
    Onodera, K
    Takahashi, T
    Yamaguchi, A
    Yuta, H
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 171 - 175
  • [22] Absolute neutron sensitivity of a GSO(Ce) scintillation detector
    Department of Nuclear Engineering, Kyushu University, Hakozaki, Higashi-ku, Fukuoka 812, Japan
    J Nucl Sci Technol, 1 (80-82):
  • [23] Optimization of a neutron image plate detector with low γ-sensitivity
    Masalovich, S
    Ioffe, A
    Schlapp, M
    von Seggern, H
    Küssel, E
    Brückel, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 539 (1-2): : 236 - 249
  • [24] Neutron sensitivity of the endcap RPC modules in Belle detector
    Abe, K
    Hoshi, Y
    Nagamine, T
    Neichi, K
    Onodera, K
    Takahashi, T
    Yamaguchi, A
    Yuta, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 831 - 835
  • [25] Study of sensitivity of combination PIN pulse neutron detector
    Zhu, XB
    Yang, HQ
    Yang, JL
    Li, BJ
    Yang, GZ
    Li, LB
    Song, XC
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2004, 28 (09): : 991 - 993
  • [26] Study on Neutron Sensitivity Calculation Model of Ex-core Neutron Detector
    Liu Y.
    Chen Z.
    Huang Y.
    Lin C.
    Gao Z.
    Luo T.
    Hedongli Gongcheng/Nuclear Power Engineering, 2024, 45 (03): : 272 - 278
  • [27] HIGH THRESHOLD SCINTILLATION NEUTRON DETECTOR
    BARANOV, PS
    GOLDANSKII, VI
    SOVIET PHYSICS JETP-USSR, 1955, 1 (03): : 576 - 579
  • [28] A HIGH-EFFICIENCY NEUTRON DETECTOR
    DUCKWORTH, JC
    MERRISON, AW
    WHITTAKER, A
    NATURE, 1950, 165 (4185) : 69 - 69
  • [29] High efficiency neutron detector for low neutron flux measurement
    Waheed A.
    Aqil-Ur-Rahman
    Zakaullah M.
    Murtaza G.
    Journal of Fusion Energy, 2000, 19 (1) : 91 - 92
  • [30] High efficiency neutron detector for low neutron flux measurement
    Waheed, A
    Aqil-ur-Rahman
    Zakaullah, M
    Murtaza, G
    JOURNAL OF FUSION ENERGY, 2000, 19 (01) : 91 - 92