Criteria Revision of Dissolved Gas Analysis for Oil-Filled Transformers in Korea

被引:0
|
作者
Cho, Sung-Min [1 ]
Kim, Jae-Chul [1 ]
机构
[1] Soongsil Univ, Dept Elect Engn, Seoul 156743, South Korea
关键词
Fault diagnosis; Maintenance; Oil insulation; Power transformers;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The story on revising criteria of Dissolved Gases Analysis (DGA) at KEPCO was introduced. Because of differences in operating environments, construction type, oil volume, and other factors, the interpretative criteria of DGA at KEPCO should be different from other standards such as IEC-60599, or Rogers and Doernenburg. We tried to improve efficiency of DGA by considering accumulated data during twenty-five years. To establish the most appropriate criteria, the DGA results were collected from healthy power transformers as well as transformers which have an incipient fault. The criteria were revised newly using cumulative distribution of concentration of 3,585 healthy power transformers. Although the criteria are revised strictly, work load doesn't increase by controlling analysis interval and condition level.
引用
收藏
页码:4057 / 4060
页数:4
相关论文
共 50 条
  • [21] Hydrogen Concentration Control in Oil-Filled Power Transformers Using Field Effect Capacitive Gas Sensors
    Litvinov, Artur
    Samotaev, Nikolay
    Etrekova, Maya
    Ivanova, Anastasia
    Filipchuk, Dmitrii
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (01)
  • [22] Acoustic Based Localization of Partial Discharge Inside Oil-Filled Transformers
    Besharatifard, Hamidreza
    Hasanzadeh, Saeed
    Heydarian-Forushani, Ehsan
    Muyeen, S. M.
    IEEE ACCESS, 2022, 10 : 55288 - 55297
  • [23] Condition Monitoring of Oil-filled Transformers using Unsupervised Classification Techniques
    Eke, Samuel
    Aka-Ngnui, Thomas
    Clerc, Guy
    Fofana, Issouf
    2017 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENON (CEIDP), 2017, : 189 - 192
  • [24] Possible Indicators of Aging in Oil-Filled Transformers Part 1: Measurements
    Birlasekaran, S.
    Ledwich, G.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2010, 26 (01) : 26 - 32
  • [25] Propagation behaviour of acoustic partial discharge signals in oil-filled transformers
    Meunier, R
    Vaillancourt, GH
    ICDL 1996 - 12TH INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN DIELECTRIC LIQUIDS, 1996, : 401 - 404
  • [26] The use of TEV sensors for online PD detection in oil-filled transformers
    Lachance, Mathieu
    Al-Gunaid, Mohammed
    2023 IEEE ELECTRICAL INSULATION CONFERENCE, EIC, 2023,
  • [27] Analysis of test norm requirements for oil-filled entrance bushings and current transformers during operation
    Polyakov V.S.
    Goldstein V.G.
    Dadonov D.N.
    Russian Electrical Engineering, 2009, 80 (7) : 388 - 391
  • [28] RMP Neural Network Based Dissolved Gas Analyzer for Fault Diagnostic of Oil-filled Electrical Equipment
    Wu, Huaren
    Li, Xiaohui
    Wu, Danning
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (02) : 495 - 498
  • [29] Condition monitoring of in-service oil-filled transformers: Case studies and experience
    Rao, U. Mohan
    Fofana, I.
    Betie, A.
    Senoussaoui, M. L.
    Brahami, M.
    Briosso, E.
    IEEE ELECTRICAL INSULATION MAGAZINE, 2019, 35 (06) : 33 - 42
  • [30] Cellulose insulation in oil-filled power transformers: Part I - History and development
    Prevost, TA
    Oommen, TV
    IEEE ELECTRICAL INSULATION MAGAZINE, 2006, 22 (01) : 28 - 35