The application of the loop-mediated isothermal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus

被引:3
|
作者
Khosravi, A. D. [1 ,2 ]
Khoshnood, S. [3 ]
Montazeri, E. Abbasi [1 ,2 ]
Jomehzadeh, N. [4 ]
Moradi, M. [1 ,2 ]
Shahi, F. [1 ,2 ]
机构
[1] Hlth Res Inst, Infect & Trop Dis Res Ctr, Ahvaz, Iran
[2] Ahvaz Jundishapur Univ Med Sci, Sch Med, Dept Microbiol, Ahvaz, Iran
[3] Ilam Univ Med Sci, Clin Microbiol Res Ctr, Ilam, Iran
[4] Abadan Fac Med Sci, Dept Microbiol, Abadan, Iran
关键词
LAMP; mecA gene; MRSA; PCR; Rapid detection; MECA; IDENTIFICATION; GENES; LAMP; NUC;
D O I
10.1016/j.nmni.2022.100960
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Methicillin-resistant Staphylococcus aureus (MRSA) is an important problem associated with significant mortality and morbidity and well known as a predominant bacterial pathogen. The aim of this study was to identify MRSA strains. In this study (June 2018 to June 2019) isolates of S. aureus were obtained from patients referred to teaching hospitals of Ahvaz, Iran. All isolates were confirmed by conventional microbiological methods. In following, antimicrobial susceptibility testing (AST), MRSA screening, PCR detection of MRSA and LAMP assay were performed. Out of a total of 156 staphylococcal isolates, 126 isolates were identified as MRSA. Seventy-two (57.1%) MRSA isolates were recovered from wound. All MRSA isolates were sensitive to vancomycin, linezolid, teicoplanin, quinupristin-dalfopristin, and tigecycline. The results of LAMP showed 100% agreement with PCR. Sensitivity and specificity of the LAMP assays for the mecA genes were 100% and 100%, respectively. The LAMP assay is a rapid and simple method for the identifications of MRSA. Because of its performance without the need for specific instrumentation, this method can be easily employed in medical centers for the detection of mecA.(c) 2022 The Authors. Published by Elsevier Ltd.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The rapid and visual detection of methicillin-susceptible and methicillin-resistant Staphylococcus aureus using multiplex loop-mediated isothermal amplification linked to a nanoparticle-based lateral flow biosensor
    Xu Chen
    Kai Ma
    Xu Yi
    Lijuan Xiong
    Yu Wang
    Shijun Li
    Antimicrobial Resistance & Infection Control, 9
  • [22] Hemoculture and Direct Sputum Detection of mecA-Mediated Methicillin-Resistant Staphylococcus aureus by Loop-Mediated Isothermal Amplification in Combination With a Lateral-Flow Dipstick
    Nawattanapaiboon, Kawin
    Prombun, Photchanathorn
    Santanirand, Pitak
    Vongsakulyanon, Apirom
    Srikhirin, Toemsak
    Sutapun, Boonsong
    Kiatpathomchai, Wansika
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (05) : 760 - 767
  • [23] A multiplex loop-mediated isothermal amplification assay for rapid detection of Bacillus cereus and Staphylococcus aureus
    Deng, Yanglong
    Liu, Yanquan
    Jiang, Zubin
    Wang, Jingxin
    Zhang, Qing
    Qian, Yeqian
    Yuan, Yuan
    Zhou, Xiangyu
    Fan, Guiling
    Li, Yufeng
    BIOSCIENCE TRENDS, 2019, 13 (06) : 510 - 515
  • [24] Development and evaluation of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus in food
    Yang, Hong
    Ma, Xiaoyan
    Zhang, Xianzhou
    Wang, Yu
    Zhang, Wei
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2011, 232 (05) : 769 - 776
  • [25] Development and evaluation of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus aureus in food
    Hong Yang
    Xiaoyan Ma
    Xianzhou Zhang
    Yu Wang
    Wei Zhang
    European Food Research and Technology, 2011, 232 : 769 - 776
  • [26] Fluorometric Paper-Based, Loop-Mediated Isothermal Amplification Devices for Quantitative Point-of-Care Detection of Methicillin-Resistant Staphylococcus aureus (MRSA)
    Choopara, Ilada
    Suea-Ngam, Akkapol
    Teethaisong, Yothin
    Howes, Philip D.
    Schmelcher, Mathias
    Leelahavanichkul, Asada
    Thunyaharn, Sudaluck
    Wongsawaeng, Doonyapong
    DeMello, Andrew J.
    Dean, Deborah
    Somboonna, Naraporn
    ACS SENSORS, 2021, 6 (03) : 742 - 751
  • [27] Design and application of a loop-mediated isothermal amplification assay for the rapid detection of Staphylococcus pseudintermedius
    Diribe, Onyinye
    North, Sarah
    Sawyer, Jason
    Roberts, Lisa
    Fitzpatrick, Noel
    La Ragione, Roberto
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (01) : 42 - 48
  • [28] Application of loop-mediated isothermal amplification on pathogens rapid detection
    Li, B., 1600, South China University of Technology (30):
  • [29] Detection of Panton-Valentine Leukocidin DNA from methicillin-resistant Staphylococcus aureus by resistive pulse sensing and loop-mediated isothermal amplification with gold nanoparticles
    Yang, Alice Kar Lai
    Lu, Haifei
    Wu, Shu Yuen
    Kwok, Ho Chin
    Ho, Ho Pui
    Yu, Samuel
    Cheung, Anthony Ka Lun
    Kong, Siu Kai
    ANALYTICA CHIMICA ACTA, 2013, 782 : 46 - 53
  • [30] Evaluation of an isothermal signal amplification method for rapid detection of methicillin-resistant Staphylococcus aureus from patient-screening swabs
    Levi, K
    Bailey, C
    Bennett, A
    Marsh, P
    Cardy, DLN
    Towner, KJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (07) : 3187 - 3191