COMPATIVE STUDIES ON PERFORMANCE OF SINGLE CELL AND PEMFC STACK

被引:2
|
作者
Onggo, Holia [1 ]
Irmawati, Yuyun [2 ]
Yudianti, Rike [1 ]
机构
[1] Indonesian Inst Sci LIPI, Res Ctr Phys, Jl Sangkuriang Kompleks LIPI, Bandung 40135, Indonesia
[2] Indonesian Inst Sci LIPI, Res Ctr Phys, Kawasan Puspiptek Serpon 15134, Tangerang Selat, Indonesia
关键词
DESIGN;
D O I
10.1063/1.4941636
中图分类号
O59 [应用物理学];
学科分类号
摘要
Single-cell, 2-cell and 3-cell of polymer electrolyte membrane fuel cells (PEMFCs) with an active area of 9 cm(2) per cell have been fabricated and characterized its performance and electrochemical properties. The membrane electrode assembly (MEA) was prepared by hot pressing commercial gas diffusion electrodes (Pt loading 0.5 mg/cm(2)) on pre-treated Nation 117 membrane. The experimental results are presented as polarization and power output curves which show the effects of varying H-2/O-2 back pressures on the PEMFC performance. Three varying H-2/O-2 volumetric flow rates for three different cell stacks were employed based on the optimal condition to produce good performance of stack. Cell performances for single cell, 2-cell, or 3-cell PEMFCs are slightly comparable with the power output 1.2 1.3 W in average. Enhancing back pressure induces increasing performance PEMFCs as indicated by changing the power from 1.19 W (open end) to 1.33W (15 psi).
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Studies on PEMFC Stack for SO2 Contamination at Air Cathode
    Prithi, J. A.
    SasankViswanath, B.
    Rajalakshmi, N.
    Dhathathreyen, K. S.
    FUEL CELLS, 2017, 17 (03) : 308 - 314
  • [22] Comparative studies of polymer electrolyte membrane fuel cell stack and single cell
    Chu, D
    Jiang, RZ
    JOURNAL OF POWER SOURCES, 1999, 80 (1-2) : 226 - 234
  • [23] Direct hybridization of PEMFC and supercapacitors: Effect of excess hydrogen on a single cell fuel cell durability and its feasibility on fuel cell stack
    Arora, Divyesh
    Bonnet, Caroline
    Mukherjee, Mainak
    Rael, Stephane
    Lapicque, Francois
    ELECTROCHIMICA ACTA, 2019, 310 : 213 - 220
  • [24] Comparative studies of polymer electrolyte membrane fuel cell stack and single cell
    Chu, Deryn
    Jiang, Rongzhong
    Journal of Power Sources, 1999, 80 (01): : 226 - 234
  • [25] Hydrogen PEMFC stack performance analysis: A data-driven approach
    Lopes, Vitor V.
    Novais, Augusto Q.
    Rangel, Carmen M.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (18) : 9973 - 9982
  • [26] Numerical analysis of PEMFC stack performance degradation using an empirical approach
    Zhao, Yan
    Luo, Maji
    Yang, Junwei
    Chen, Ben
    Sui, Pang-Chieh
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 56 : 147 - 163
  • [27] Experimental analysis of the CHP performance of a PEMFC stack by a 24 factorial design
    Torchio, MF
    Santarelli, MG
    Nicali, A
    JOURNAL OF POWER SOURCES, 2005, 149 : 33 - 43
  • [28] Experimental analysis of cathode flow stoichiometry on the electrical performance of a PEMFC stack
    Santarelli, M. G.
    Torchio, M. F.
    Cali, M.
    Giaretto, V.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (06) : 710 - 716
  • [29] Identification of critical parameters for PEMFC stack performance characterization and control strategies for reliable and comparable stack benchmarking
    Mitzel, Jens
    Gulzow, Erich
    Kabza, Alexander
    Hunger, Jurgen
    Araya, Samuel Simon
    Piela, Piotr
    Alecha, Iker
    Tsotridis, Georgios
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2016, 41 (46) : 21415 - 21426
  • [30] Experimental Performance of an Air-Breathing 100 W Polymer Electrolyte Membrane Fuel Cell (PEMFC) Stack
    Gregoris, Panayiotou
    Petros, Axaopoulos
    Ioannis, Fyrippis
    RES 08: PROCEEDINGS OF THE 2ND WSEAS/IASME INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY SOURCES, 2008, : 198 - 203