摘要
Laryngeal control of expiratory airflow is a principal means by which the newborn establishes and maintains absolute lung volume. Specifically, retardation of expiratory airflow is effected by the major adductors of the larynx, the thyroarytenoid (TA) muscles. The long-term aim of this research is to determine if monitoring TA activity can be used to optimize absolute lung volume during artificial ventilation of the human baby, This initial study, performed in unanesthetized chronically instrumented newborn lambs, tests the hypothesis that the timings of the onsets, peaks and durations of TA activity recorded by the endotracheal electrode a re equivalent to those measured by a surgically placed intramuscular electrode. Endotracheal measurement of TA activity is accurate and specific and can monitor changes in airway pressure and lung volume. Copyright (C) 2000 S. Karger AG, Basel.
引用
收藏
页码:139 / 144
页数:6
相关论文
共 50 条
  • [21] IMMUNOSUPPRESSION IN NEWBORN LAMBS
    BROEKMAN, J
    EKSTEEN, PAL
    VERWOERD, DW
    ONDERSTEPOORT JOURNAL OF VETERINARY RESEARCH, 1977, 44 (03) : 151 - 156
  • [22] FEVER IN NEWBORN LAMBS
    PITTMAN, QJ
    COOPER, KE
    VEALE, WL
    VANPETTE.GR
    CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1973, 51 (11) : 868 - 872
  • [23] THE ENTROPION IN NEWBORN LAMBS
    LAMPRECHT, H
    PFEIFFER, A
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 1989, 102 (09): : 303 - 310
  • [24] ENTROPION IN NEWBORN LAMBS
    WINTER, AC
    VETERINARY RECORD, 1984, 114 (10) : 251 - 251
  • [25] INTRA-AORTIC TRANSFUSION OF OXYGENATED BLOOD AND ENDOTRACHEAL INSUFFLATION OF OXYGEN IN THE RESUSCITATION OF SEVERELY ANOXIC NEWBORN LAMBS
    BRANDT, IK
    CUNNINGHAM, P
    HARNED, HS
    PEDIATRICS, 1960, 25 (05) : 859 - 868
  • [26] Evaluating the efficacy of endotracheal and intranasal epinephrine administration in severely asphyxic bradycardic newborn lambs: a randomised preclinical study
    de Jager, Justine
    Pothof, Romy
    Crossley, Kelly J.
    Schmolzer, Georg M.
    te Pas, Arjan B.
    Galinsky, Robert
    Tran, Nhi T.
    Songstad, Nils Thomas
    Klingenberg, Claus
    Hooper, Stuart B.
    Polglase, Graeme R.
    Roberts, Calum T.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2024,
  • [27] ENDOTRACHEAL SUCTIONING OF THE NEWBORN PIGLET
    GUNDERSON, LP
    STOECKLE, ML
    WESTERN JOURNAL OF NURSING RESEARCH, 1995, 17 (01) : 20 - 31
  • [28] MISPLACED ENDOTRACHEAL TUBE IN NEWBORN
    PANDE, YN
    BRITISH MEDICAL JOURNAL, 1972, 3 (5820): : 237 - &
  • [29] Electrocortical brain activity during hypoxia and hypotension in anesthetized newborn lambs
    van de Bor, M
    Meinesz, J
    Benders, MJNL
    Steendijk, P
    Cardozo, RHL
    van Bel, F
    EARLY HUMAN DEVELOPMENT, 1999, 55 (03) : 237 - 245
  • [30] EFFECTS OF ALMITRINE BISMESYLATE ON CHEMORECEPTOR ACTIVITY IN FETAL SHEEP AND NEWBORN LAMBS
    BLANCO, CE
    HANSON, MA
    MCCOOKE, HB
    EUROPEAN JOURNAL OF RESPIRATORY DISEASES, 1983, 64 : 313 - 317