PM2.5 and ultrafine particulate matter emissions from natural gas-fired turbine for power generation

被引:24
|
作者
Brewer, Eli [1 ]
Li, Yang [1 ]
Finken, Bob [2 ]
Quartucy, Greg [3 ]
Muzio, Lawrence [3 ]
Baez, Al [4 ]
Garibay, Mike [4 ]
Jung, Heejung S. [1 ]
机构
[1] Univ Calif Riverside, Dept Mech Engn, Riverside, CA 92521 USA
[2] Delta Air Qual Serv Inc, 1845 North Case St, Orange, CA 92865 USA
[3] Fossil Energy Res Corp FERCo, 23342-C South Pointe Dr, Laguna Hills, CA 92653 USA
[4] SCAQMD, 21865 Copley Dr, Diamond Bar, CA 91765 USA
关键词
Atmospheric nanoparticle; Method; 201A; 5.1; Emission; PARTICLES; AIRCRAFT; DENSITY;
D O I
10.1016/j.atmosenv.2015.11.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The generation of electricity from natural gas-fired turbines has increased more than 200% since 2003. In 2007 the South Coast Air Quality Management District (SCAQMD) funded a project to identify control strategies and technologies for PM2.5 and ultrafine emissions from natural gas-fired turbine power plants and test at pilot scale advanced PM2.5 technologies to reduce emissions from these gas turbine-based power plants. This prompted a study of the exhaust from new facilities to better understand air pollution in California. To characterize the emissions from new natural gas turbines, a series of tests were performed on a GE LMS100 gas turbine located at the Walnut Creek Energy Park in August 2013. These tests included particulate matter less than 2.5 mu m in diameter (PM2.5) and wet chemical tests for SO2/SO3 and NH3, as well as ultrafine (less than 100 nm in diameter) particulate matter measurements. After turbine exhaust was diluted sevenfold with filtered air, particle concentrations in the 10-300 nm size range were approximately two orders of magnitude higher than those in the ambient air and those in the 2-3 nm size range were up to four orders of magnitude higher. This study also found that ammonia emissions were higher than expected, but in compliance with permit conditions. This was possibly due to an ammonia imbalance entering the catalyst, some flue gas bypassing the catalyst, or not enough catalyst volume. SO3 accounted for an average of 23% of the total sulfur oxides emissions measured. While some of the SO3 is formed in the combustion process, it is likely that the majority formed as the SO2 in the combustion products passed across the oxidizing CO catalyst and SCR catalyst. The 100 MW turbine sampled in this study emitted particle loadings of 3.63E-04 lb/MMEtu based on Methods 5.1/201A and 1.07E-04 lb/MMBtu based on SMPS method, which are similar to those previously measured from turbines in the SCAQMD area (FERCo et al., 2014), however, the turbine exhaust contained orders of magnitude higher particles than ambient air. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [31] Development of advanced electrostatic precipitation technologies for reducing PM2.5 emissions from coal-fired power plants
    Xiong, Guilong
    Li, Shuiqing
    Chen, Sheng
    Zhang, Xuhui
    Yao, Qiang
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2015, 35 (09): : 2217 - 2223
  • [32] Cluster analysis of fine particulate matter (PM2.5) emissions and its bioreactivity in the vicinity of a petrochemical complex
    Chuang, Hsiao-Chi
    Shie, Ruei-Hao
    Chio, Chia-Pin
    Yuan, Tzu-Hsuen
    Lee, Jui-Huan
    Chan, Chang-Chuan
    ENVIRONMENTAL POLLUTION, 2018, 236 : 591 - 597
  • [33] On-road particulate matter (PM2.5) and gaseous emissions in the Shing Mun Tunnel, Hong Kong
    Cheng, Y.
    Lee, S. C.
    Ho, K. F.
    Louie, P. K. K.
    ATMOSPHERIC ENVIRONMENT, 2006, 40 (23) : 4235 - 4245
  • [34] Evaluating the Impact of Vehicular Aerosol Emissions on Particulate Matter (PM2.5) Formation Using Modeling Study
    Sanchez-Ccoyllo, Odon R.
    Llacza, Alan
    Ayma-Choque, Elizabeth
    Alonso, Marcelo
    Castesana, Paula
    Andrade, Maria de Fatima
    ATMOSPHERE, 2022, 13 (11)
  • [35] Particulate characteristics data for the management of PM2.5 emissions from stationary combustion sources
    Lee, S. Win
    Herage, T.
    He, I.
    Young, B.
    POWDER TECHNOLOGY, 2008, 180 (1-2) : 145 - 150
  • [36] THE EFFECTS OF LOAD HEIGHT ON THE EMISSIONS FROM A NATURAL GAS-FIRED DOMESTIC COOKTOP BURNER
    ASHMAN, PJ
    JUNUS, R
    STUBINGTON, JF
    SERGEANT, GD
    COMBUSTION SCIENCE AND TECHNOLOGY, 1994, 103 (1-6) : 283 - 298
  • [37] Do smart cities have lower particulate matter 2.5 (PM2.5)? Evidence from China
    Cui, Huan-yu
    Cao, Yue-qun
    SUSTAINABLE CITIES AND SOCIETY, 2022, 86
  • [38] Comparison of Coal-fired and Natural Gas-fired Power Plants as Economically Viable and Ecologically Sustainable Power Generation Systems
    Sampattagul, Sate
    Kato, Seizo
    Kiatsiriroat, Tanongkiat
    Maruyama, Naoki
    Nishimura, Akira
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2005, 3 (02):
  • [39] Discussion on the Emission Control of PM2.5 from Coal-fired Power Plants
    Pan, Xueqin
    Zheng, Jinlang
    Wang, Jianchun
    Jin, Yujian
    Jiang, Minmin
    ENERGY, ENVIRONMENT AND ENGINEERING, 2012, 4 : 26 - 28
  • [40] Role of metals in free radical generation and genotoxicity induced by airborne particulate matter (PM2.5) from Pune (India)
    Suman Yadav
    Rohi Jan
    Ritwika Roy
    P. Gursumeeran Satsangi
    Environmental Science and Pollution Research, 2016, 23 : 23854 - 23866