PM2.5 and ultrafine particulate matter emissions from natural gas-fired turbine for power generation

被引:24
|
作者
Brewer, Eli [1 ]
Li, Yang [1 ]
Finken, Bob [2 ]
Quartucy, Greg [3 ]
Muzio, Lawrence [3 ]
Baez, Al [4 ]
Garibay, Mike [4 ]
Jung, Heejung S. [1 ]
机构
[1] Univ Calif Riverside, Dept Mech Engn, Riverside, CA 92521 USA
[2] Delta Air Qual Serv Inc, 1845 North Case St, Orange, CA 92865 USA
[3] Fossil Energy Res Corp FERCo, 23342-C South Pointe Dr, Laguna Hills, CA 92653 USA
[4] SCAQMD, 21865 Copley Dr, Diamond Bar, CA 91765 USA
关键词
Atmospheric nanoparticle; Method; 201A; 5.1; Emission; PARTICLES; AIRCRAFT; DENSITY;
D O I
10.1016/j.atmosenv.2015.11.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The generation of electricity from natural gas-fired turbines has increased more than 200% since 2003. In 2007 the South Coast Air Quality Management District (SCAQMD) funded a project to identify control strategies and technologies for PM2.5 and ultrafine emissions from natural gas-fired turbine power plants and test at pilot scale advanced PM2.5 technologies to reduce emissions from these gas turbine-based power plants. This prompted a study of the exhaust from new facilities to better understand air pollution in California. To characterize the emissions from new natural gas turbines, a series of tests were performed on a GE LMS100 gas turbine located at the Walnut Creek Energy Park in August 2013. These tests included particulate matter less than 2.5 mu m in diameter (PM2.5) and wet chemical tests for SO2/SO3 and NH3, as well as ultrafine (less than 100 nm in diameter) particulate matter measurements. After turbine exhaust was diluted sevenfold with filtered air, particle concentrations in the 10-300 nm size range were approximately two orders of magnitude higher than those in the ambient air and those in the 2-3 nm size range were up to four orders of magnitude higher. This study also found that ammonia emissions were higher than expected, but in compliance with permit conditions. This was possibly due to an ammonia imbalance entering the catalyst, some flue gas bypassing the catalyst, or not enough catalyst volume. SO3 accounted for an average of 23% of the total sulfur oxides emissions measured. While some of the SO3 is formed in the combustion process, it is likely that the majority formed as the SO2 in the combustion products passed across the oxidizing CO catalyst and SCR catalyst. The 100 MW turbine sampled in this study emitted particle loadings of 3.63E-04 lb/MMEtu based on Methods 5.1/201A and 1.07E-04 lb/MMBtu based on SMPS method, which are similar to those previously measured from turbines in the SCAQMD area (FERCo et al., 2014), however, the turbine exhaust contained orders of magnitude higher particles than ambient air. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:141 / 149
页数:9
相关论文
共 50 条
  • [1] Observations of Methane Emissions from Natural Gas-Fired Power Plants
    Hajny, Kristian D.
    Salmon, Olivia E.
    Rudek, Joseph
    Lyon, David R.
    Stuff, Andrew A.
    Stirm, Brian H.
    Kaeser, Robert
    Floerchinger, Cody R.
    Conley, Stephen
    Smith, Mackenzie L.
    Shepson, Paul B.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2019, 53 (15) : 8976 - 8984
  • [2] The Need for Alternate PM2.5 Emission Factors for Gas-Fired Combustion Units
    Corio, Louis
    Olson, Karen
    POWER, 2015, 159 (07) : 51 - 54
  • [3] Refined assessment of size-fractioned particulate matter (PM2.5/PM10/PMtotal) emissions from coal-fired power plants in China
    Wu, Bobo
    Tian, Hezhong
    Hao, Yan
    Liu, Shuhan
    Sun, Yujiao
    Bai, Xiaoxuan
    Liu, Wei
    Lin, Shumin
    Zhu, Chuanyong
    Hao, Jiming
    Luo, Lining
    Zhao, Shuang
    Guo, Zhihui
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 706
  • [4] Network Analysis of Fine Particulate Matter (PM2.5) Emissions in China
    Yan, Shaomin
    Wu, Guang
    SCIENTIFIC REPORTS, 2016, 6
  • [5] Network Analysis of Fine Particulate Matter (PM2.5) Emissions in China
    Shaomin Yan
    Guang Wu
    Scientific Reports, 6
  • [6] Rise in gas-fired power generation tracks gains in turbine efficiency
    Bautista, Paul
    Oil and Gas Journal, 1996, 94 (33):
  • [7] Rise in gas-fired power generation tracks gains in turbine efficiency
    Bautista, P
    OIL & GAS JOURNAL, 1996, 94 (33) : 43 - &
  • [8] Particulate matter concentrations around natural gas-fired power plants and their associated health impact assessment
    Rahman, Mustafizur
    Hasan, Kamrul
    Siddique, Md. Abu Bakar
    Ambade, Balram
    Hussain, Md. Alamgir
    Salam, Mohammed Abdus
    Tariq, Salman
    Ibrahim, Muhammad
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2024, 36 (07)
  • [9] Assessing the Methane Emissions from Natural Gas-Fired Power Plants and Oil Refineries
    Lavoie, Tegan N.
    Shepson, Paul B.
    Gore, Chloe A.
    Stirm, Brian H.
    Kaeser, Robert
    Wulle, Bernard
    Lyon, David
    Rudek, Joseph
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (06) : 3373 - 3381
  • [10] Implications for UK coal-fired power stations of a move to a particulate matter standard based on PM2.5
    Griffiths, Stephen
    Booth, Victoria
    Lennard, Robert
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2011, 44 (1-4) : 252 - 260