Discrimination of neutrons and gamma-rays in plastic scintillator based on falling-edge percentage slope method

被引:8
|
作者
Zuo, Zhuo [1 ,2 ]
Xiao, Yulong [1 ]
Liu, Zhenfeng [1 ]
Liu, Bingqi [3 ]
Yan, Yucheng [1 ,2 ]
机构
[1] Chengdu Univ Technol, Engn & Tech Coll, Leshan 614000, Sichuan, Peoples R China
[2] Southwestern Inst Phys, Chengdu 610225, Peoples R China
[3] Chengdu Univ, Chengdu 610106, Peoples R China
关键词
Neutron detection; Neutron and gamma discrimination; Filtering; Percentage slope method; Angle difference method; PULSE-SHAPE DISCRIMINATION; THERMAL-NEUTRONS; TRANSFORM;
D O I
10.1016/j.nima.2021.165483
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
With the development of neutron detection technology, the demand for real-time and fast neutron gamma discrimination has become of increasing importance. In this study, neutron and gamma pulse signals measured by an EJ299-33A plastic scintillator detector were analyzed via Matlab off-line. This study compares the effects of seven fast neutron and gamma (n/gamma) discrimination methods; (i) charge comparison method, (ii) time-domain oriented method, (iii) amplitude oriented method, (iv) pulse time-amplitude two types of width method, (v) angle difference method, (vi) falling-edge numerical integral method, and, lastly, (vii) falling-edge percentage slope method proposed in this study. We verified that filtering and amplitude normalization improve the discrimination quality but consume much time that accounts for 99.6% of the total discrimination time. The proposed method was compared with other six methods in two aspects: (i) the figure of merit (FoM), (ii) the discrimination time. The FoM value and time consumption of the falling-edge percentage slope method with amplitude normalization are 1.26 and 0.0621s, respectively, while an unnormalized FoM value is 1.02. Experimental results showed that compared with all aforementioned methods, the FoM value of our proposed method is the second high followed the charge comparison method, retaining a short discrimination time which is only half of that of the charge comparison method. This relatively short time consuming is on account of its low volume of data storage and calculation. Generally, the falling-edge percentage slope method has a good discrimination performance while consumes little time, which is capable to be implemented on real-time discrimination applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] COMPOSITE TLD BASED ON CASO4-TM FOR GAMMA-RAYS, X-RAYS, BETA-RAYS AND THERMAL-NEUTRONS
    IGA, K
    YAMASHITA, T
    TAKENAGA, M
    YASUNO, Y
    OONISHI, H
    IKEDO, M
    HEALTH PHYSICS, 1977, 33 (06): : 605 - 610
  • [42] Study of properties of the plastic scintillator EJ-260 under irradiation with 150 MeV protons and 1.2MeV gamma-rays
    Dormenev, V.
    Brinkmann, K. -T.
    Korjik, M.
    Novotny, R. W.
    17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
  • [43] Wavelet-based digital pulse-shape method for discrimination between neutron and gamma-rays with organic scintillation detectors
    Alharbi, Thamer
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2024, 36 (08)
  • [44] Discrimination of hydroxyl radical yields due to thermal neutrons, fast neutrons, and gamma rays in accelerator-based neutron fields
    Ogawara, Ryo
    Kusumoto, Tamon
    Kobayashi, Alisa
    Konishi, Teruaki
    Hamano, Tsuyoshi
    Kodaira, Satoshi
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [45] Relative sensitivity of plastic scintillator: A comparative analysis with 60Co gamma rays, deuterium-deuterium, and deuterium-tritium neutrons
    Kim, Y.
    Meaney, K. D.
    Leeper, R. J.
    Batha, S. H.
    Jorgenson, H. J.
    Perry, T. S.
    Dwyer, R. H.
    Schmidt, T. R.
    Hochanadel, M. P.
    Sweeney, J. R.
    Archuleta, T. N.
    White, B.
    Richardson, R.
    Green, J. A.
    Wolverton, A. J.
    Guckes, A.
    Lowe, D. R.
    Showers, M.
    Willis, C. A.
    Butcher, M. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (09):
  • [46] MEASUREMENT OF THERMAL-NEUTRONS AND GAMMA-RAYS IN A MIXED RADIATION-FIELD BASED ON CAPTURE GAMMA OR SELF IRRADIATION OF THERMOLUMINESCENT DOSIMETERS
    HSU, PC
    TSENG, CL
    LI, SH
    WENG, PS
    NUCLEAR INSTRUMENTS & METHODS, 1978, 154 (03): : 561 - 566
  • [47] APPLICATION OF A150 PLASTIC-EQUIVALENT GAS IN A150 PLASTIC IONIZATION CHAMBERS FOR CO-60 GAMMA-RAYS AND 14.8-MEV NEUTRONS
    DELUCA, PM
    ATTIX, FH
    PEARSON, DW
    SCHELL, MC
    AWSCHALOM, M
    MEDICAL PHYSICS, 1982, 9 (03) : 378 - 384
  • [48] Author Correction: Compact lightweight imager of both gamma rays and neutrons based on a pixelated stilbene scintillator coupled to a silicon photomultiplier array
    Jihwan Boo
    Mark D. Hammig
    Manhee Jeong
    Scientific Reports, 11
  • [49] NEUTRON-GAMMA DISCRIMINATION USING ZERO-CROSSING METHOD FOR BC454 BORON LOADED PLASTIC SCINTILLATOR
    Wang Dong
    He Bin
    Zhang Quanhu
    PROCEEDINGS OF THE 18TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING 2010, VOL 3, 2011, : 89 - +
  • [50] A METHOD FOR DETECTION OF EXPLOSIVES BASED ON NUCLEAR-RESONANCE ABSORPTION OF GAMMA-RAYS IN N-14
    VARTSKY, D
    ENGLER, G
    GOLDBERG, MB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 688 - 691