Discrimination of neutrons and gamma-rays in plastic scintillator based on falling-edge percentage slope method

被引:8
|
作者
Zuo, Zhuo [1 ,2 ]
Xiao, Yulong [1 ]
Liu, Zhenfeng [1 ]
Liu, Bingqi [3 ]
Yan, Yucheng [1 ,2 ]
机构
[1] Chengdu Univ Technol, Engn & Tech Coll, Leshan 614000, Sichuan, Peoples R China
[2] Southwestern Inst Phys, Chengdu 610225, Peoples R China
[3] Chengdu Univ, Chengdu 610106, Peoples R China
关键词
Neutron detection; Neutron and gamma discrimination; Filtering; Percentage slope method; Angle difference method; PULSE-SHAPE DISCRIMINATION; THERMAL-NEUTRONS; TRANSFORM;
D O I
10.1016/j.nima.2021.165483
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
With the development of neutron detection technology, the demand for real-time and fast neutron gamma discrimination has become of increasing importance. In this study, neutron and gamma pulse signals measured by an EJ299-33A plastic scintillator detector were analyzed via Matlab off-line. This study compares the effects of seven fast neutron and gamma (n/gamma) discrimination methods; (i) charge comparison method, (ii) time-domain oriented method, (iii) amplitude oriented method, (iv) pulse time-amplitude two types of width method, (v) angle difference method, (vi) falling-edge numerical integral method, and, lastly, (vii) falling-edge percentage slope method proposed in this study. We verified that filtering and amplitude normalization improve the discrimination quality but consume much time that accounts for 99.6% of the total discrimination time. The proposed method was compared with other six methods in two aspects: (i) the figure of merit (FoM), (ii) the discrimination time. The FoM value and time consumption of the falling-edge percentage slope method with amplitude normalization are 1.26 and 0.0621s, respectively, while an unnormalized FoM value is 1.02. Experimental results showed that compared with all aforementioned methods, the FoM value of our proposed method is the second high followed the charge comparison method, retaining a short discrimination time which is only half of that of the charge comparison method. This relatively short time consuming is on account of its low volume of data storage and calculation. Generally, the falling-edge percentage slope method has a good discrimination performance while consumes little time, which is capable to be implemented on real-time discrimination applications.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Discrimination of neutrons and gamma-rays in plastic scintillator based on spiking cortical model
    Liu, Bing-Qi
    Liu, Hao-Ran
    Chang, Lan
    Cheng, Yu-Xin
    Zuo, Zhuo
    Li, Peng
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2023, 55 (09) : 3359 - 3366
  • [2] Discrimination of neutrons and gamma rays in plastic scintillator based on pulse-coupled neural network
    Hao-Ran Liu
    Yu-Xin Cheng
    Zhuo Zuo
    Tian-Tian Sun
    Kai-Min Wang
    Nuclear Science and Techniques, 2021, 32
  • [3] Discrimination of neutrons and gamma rays in plastic scintillator based on pulse-coupled neural network
    Liu, Hao-Ran
    Cheng, Yu-Xin
    Zuo, Zhuo
    Sun, Tian-Tian
    Wang, Kai-Min
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (08)
  • [4] Discrimination of neutrons and gamma rays in plastic scintillator based on pulse-coupled neural network
    Hao-Ran Liu
    Yu-Xin Cheng
    Zhuo Zuo
    Tian-Tian Sun
    Kai-Min Wang
    NuclearScienceandTechniques, 2021, 32 (08) : 50 - 58
  • [5] Study of Pulse Shape Discrimination of Sub-MeV Neutrons from Gamma-rays with Liquid Scintillator
    Yoshioka, M.
    Ueyama, M.
    Koba, Y.
    Nakamura, Y.
    Kajimoto, T.
    Moriguchi, D.
    Uozumi, Y.
    Shigyo, N.
    Sato, D.
    Sanami, T.
    Takada, M.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 1971 - 1974
  • [6] Plastic scintillator for pulse shape neutrons and gamma quanta discrimination
    Zhmurin, P. N.
    Lebedev, V. N.
    Adadurov, A. F.
    Pereymak, V. N.
    Gurkalenko, Yu A.
    RADIATION MEASUREMENTS, 2014, 62 : 1 - 5
  • [7] PLASTIC TL DETECTOR FOR FAST NEUTRONS PLUS GAMMA-RAYS
    FACEY, RA
    GRAVELLE, RA
    HEALTH PHYSICS, 1974, 27 (06): : 621 - 622
  • [8] Effects of neutrons and gamma-rays on polymethylmethacrylate plastic optical fiber
    Toh, K.
    Sakasai, K.
    Nakamura, T.
    Soyama, K.
    Shikama, T.
    JOURNAL OF NUCLEAR MATERIALS, 2011, 417 (1-3) : 814 - 817
  • [9] Optimization of Plastic Scintillator for Detection of Gamma-Rays: Simulation and Experimental Study
    Min, Sujung
    Kim, Youngsu
    Ko, Kwang-Hoon
    Seo, Bumkyung
    Cheong, JaeHak
    Roh, Changhyun
    Hong, Sangbum
    CHEMOSENSORS, 2021, 9 (09)
  • [10] Digital discrimination of neutrons and gamma-rays in liquid scintillators using wavelets
    Yousefi, S.
    Lucchese, L.
    Aspinall, M. D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 598 (02): : 549 - 553