Pitometry as a validation tool for water flow measurement in large diameter pipelines

被引:0
|
作者
Kawakita, Kazuto [1 ]
Taira, Nilson Massami [1 ]
Ruiz, Valmir [1 ]
机构
[1] IPT Inst Pesquisas Tecnol, Av Prof Almeida Prado 532, BR-05508901 Sao Paulo, SP, Brazil
关键词
Cole type Pitot tube; Pitometry in large pipes; Water flowrate measurement; Flow velocity profile; Field calibration of water flowmeter; Pitometry technique;
D O I
10.1016/j.flowmeasinst.2021.101895
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Accurate measurement of water flow rates in large diameter pipelines is a challenge for water companies that need to produce, transport and distribute increasing quantities of water. To a large extent, this challenge results from the impossibility of recalibration of the flow meters within the periodicity established in the metrological regulations since the removal of a large size flow meter from its site of operation in the field and its transport to a calibration laboratory is in most cases technically and economically impracticable. Because of this scenario, this paper presents the pitometry technique as an interesting alternative to solve problems related to the validation of water flow measurements performed by flow measurement systems installed in large diameter conduits. The technique is based on the determination of the water flow rate by mapping the velocity profile of the water flow inside the pipe by means of Cole type Pitot tubes. The water flow rate is determined in a cross section of the pipe located near and in series to the flowmeter to be evaluated. Based on the results obtained in a great number of water flow measurements already performed by applying the pitometry technique in large diameter pipelines in the field, it is possible to conclude that this methodology is perfectly applicable in the validation of the performance of flow meters installed in these conduits solving satisfactorily the issues related to its operation.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Estimating stand water use of large mountain ash trees and validation of the sap flow measurement technique
    Vertessy, RA
    Hatton, TJ
    Reece, P
    OSullivan, SK
    Benyon, RG
    TREE PHYSIOLOGY, 1997, 17 (12) : 747 - 756
  • [22] Flow measurement of particulate solids in pipelines
    Yan, Y
    FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (03) : 151 - 151
  • [23] ESCARPMENT CROSSING DESIGN AND ANALYSES OF LARGE DIAMETER OFFSHORE PIPELINES
    Qi, Xinhai
    Kvist, Orjan
    Chen, Jian
    Duan, Gang
    Ren, Lan
    Wang, Howard
    Lan, Jundong
    PROCEEDINGS OF ASME 2024 43RD INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, OMAE2024, VOL 3, 2024,
  • [24] Liquid holdup in large-diameter horizontal multiphase pipelines
    Maley, LC
    Jepson, WP
    JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1998, 120 (03): : 185 - 191
  • [25] Influencing factors and correction analysis of large diameter ultrasonic flow measurement error
    Wang F.
    Zeng Y.
    Zhang Z.
    Zhang J.
    Yang G.
    Qian J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (03): : 146 - 153
  • [26] Recoating large diameter gas transmission pipelines in Western Canada
    Leahy, TD
    Prior, MR
    Taylor, SA
    AGEING PIPELINES: OPTIMIZING THE MANAGEMENT AND OPERATION: LOW-PRESSURE - HIGH-PRESSURE, 1999, 1999 (08): : 225 - 234
  • [27] LARGE DIAMETER MAIN PIPELINES WELDED AT LOW-TEMPERATURES
    ZAITSEV, KI
    MAZEL, AG
    AUTOMATIC WELDING USSR, 1972, 25 (12): : 47 - 53
  • [28] USE OF LARGE DIAMETER POLYTHENE PIPELINES BY BRITISH GAS.
    Greig, J.M.
    Pipes and Pipelines International, 1977, 22 (01): : 16 - 24
  • [29] Sodium flow measurement in large pipelines of sodium cooled fast breeder reactors with bypass type flow meters
    Rajan, K. K.
    Jayakumar, T.
    Aggarwal, P. K.
    Vinod, V.
    ANNALS OF NUCLEAR ENERGY, 2016, 87 : 74 - 80
  • [30] MEASUREMENT OF LARGE-DIAMETER BORES
    MINAIRE, C
    MACHINERY AND PRODUCTION ENGINEERING, 1971, 118 (3047): : 528 - &