Knowledge-based planning for oesophageal cancers using a model trained with plans from a different treatment planning system

被引:17
|
作者
Ueda, Yoshihiro [1 ,2 ]
Miyazaki, Masayoshi [1 ]
Sumida, Iori [2 ]
Ohira, Shingo [1 ]
Tamura, Mikoto [3 ]
Monzen, Hajime [3 ]
Tsuru, Haruhi [1 ]
Inui, Shoki [1 ]
Isono, Masaru [1 ]
Ogawa, Kazuhiko [2 ]
Teshima, Teruki [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Grad Sch Med, Dept Radiat Oncol, 2-2 Yamada Oka, Suita, Osaka 5650071, Japan
[3] Kindai Univ, Grad Sch Med Sci, Dept Med Phys, Osaka, Japan
关键词
MODULATED ARC THERAPY; CELL LUNG-CANCER; VMAT; HEAD; RADIOTHERAPY; OPTIMIZATION; PERFORMANCE; IMRT;
D O I
10.1080/0284186X.2019.1691257
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: This study aimed to evaluate knowledge-based volume modulated arc therapy (VMAT) plans for oesophageal cancers using a model trained with plans optimised with a different treatment planning system (TPS) and to compare lung dose sparing in two TPSs, Eclipse and RayStation. Materials and methods: A total of 64 patients with stage I-III oesophageal cancers were treated using hybrid VMAT (H-VMAT) plans optimised using RayStation. Among them, 40 plans were used for training the model for knowledge-based planning (KBP) in RapidPlan. The remaining 24 plans were recalculated using RapidPlan to validate the KBP model. H-VMAT plans calculated using RapidPlan were compared with H-VMAT plans optimised using RayStation with respect to planning target volume doses, lung doses, and modulation complexity. Results: In the lung, there were significant differences between the volume ratios receiving doses in excess of 5, 10, and 20 Gy (V-5, V-10, and V-20). The V-5 for the lung with H-VMAT plans optimised using RapidPlan was significantly higher than that of H-VMAT plans optimised using RayStation (p < .01), with a mean difference of 10%. Compared to H-VMAT plans optimised using RayStation, the V-10 and V-20 for the lung were significantly lower with H-VMAT plans optimised using RapidPlan (p = .04 and p = .02), with differences exceeding 1.0%. In terms of modulation complexity, the change in beam output at each control point was more constant with H-VMAT plans optimised using RapidPlan than with H-VMAT plans optimised using RayStation. The range of the change with H-VMAT plans optimised using RapidPlan was one third that of H-VMAT plans optimised using RayStation. Conclusion: Two optimisers in Eclipse and RayStation had different dosimetric performance in lung sparing and modulation complexity. RapidPlan could not improve low lung doses, however, it provided an appreciate intermediated doses compared to plans optimised with RayStation.
引用
收藏
页码:274 / 283
页数:10
相关论文
共 50 条
  • [31] Integrating design and production planning with knowledge-based inspection planning system
    Abbasi, GY
    Ketan, HS
    Adil, MB
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2005, 30 (2B): : 245 - 260
  • [32] Knowledge-based planning for fully automated radiation therapy treatment planning of 10 different cancer sites
    Chung, Christine, V
    Khan, Meena S.
    Olanrewaju, Adenike
    Pham, Mary
    Nguyen, Quyen T.
    Patel, Tina
    Das, Prajnan
    O'Reilly, Michael S.
    Reed, Valerie K.
    Jhingran, Anuja
    Simonds, Hannah
    Ludmir, Ethan B.
    Hoffman, Karen E.
    Naidoo, Komeela
    Parkes, Jeannette
    Aggarwal, Ajay
    Mayo, Lauren L.
    Shah, Shalin J.
    Tang, Chad
    Beadle, Beth M.
    Wetter, Julie
    Walker, Gary
    Hughes, Simon
    Mullassery, Vinod
    Skett, Stephen
    Thomas, Christopher
    Zhang, Lifei
    Nguyen, Son
    Mumme, Raymond P.
    Douglas, Raphael J.
    Baroudi, Hana
    Court, Laurence E.
    RADIOTHERAPY AND ONCOLOGY, 2025, 202
  • [33] Feasibility of Using Historical Helical 3DRT and IMRT System Plans for VMAT-Based Total Marrow Irradiation Planning with the Knowledge-Based Treatment Planning Technique
    Han, C.
    Wong, J. Y. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S237 - S237
  • [34] A knowledge-based system to model human supervisory control in dynamic planning
    Dave, R
    Ganapathy, S
    Fendley, M
    Narayanan, S
    INTERNATIONAL JOURNAL OF UNCERTAINTY FUZZINESS AND KNOWLEDGE-BASED SYSTEMS, 2004, 12 : 1 - 14
  • [35] Commissioning of a Prostate Model Created Using Knowledge-Based Planning as a Tool to Guide the Planning Process
    Aviles, J. E. Alpuche
    Sasaki, D.
    Sutherland, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S870 - S870
  • [36] KNOWLEDGE-BASED TEST PLANNING - FRAMEWORK FOR A KNOWLEDGE-BASED SYSTEM TO PREPARE A SYSTEM TEST PLAN FROM SYSTEM REQUIREMENTS
    SAMSON, D
    JOURNAL OF SYSTEMS AND SOFTWARE, 1993, 20 (02) : 115 - 124
  • [37] Using GIS and Knowledge-Based System for Agricultural Land Drainage Planning
    Adly, Ashraf
    Fattouh, Lamia
    Moustafa, Mahmoud
    Abd Elmoneim, Atef
    3RD ACS/IEEE INTERNATIONAL CONFERENCE ON COMPUTER SYSTEMS AND APPLICATIONS, 2005, 2005,
  • [38] Training and Evaluation of a Knowledge-based Planning System for Treatment Planning of Malignant Pleural Mesothelioma to the Intact Lungs
    Dumane, V. A.
    Rosenzweig, K.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : S236 - S237
  • [39] Knowledge-Based Planning Assisted Automatic Prostate Cancer Radiation Treatment Planning
    Chen, L.
    Xiong, Z.
    Godley, A.
    Jiang, S.
    Lin, M.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Knowledge-based IMRT optimisation using a model trained with VMAT plans of other setup orientations
    Zhang, Y.
    Jiang, F.
    Li, S.
    Yue, H.
    Hu, Q.
    Wu, H.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S758 - S758