Automated interpretation of congenital heart disease from multi-view echocardiograms

被引:47
|
作者
Wang, Jing [1 ]
Liu, Xiaofeng [3 ,6 ]
Wang, Fangyun [2 ]
Zheng, Lin [2 ]
Gao, Fengqiao [1 ]
Zhang, Hanwen [1 ]
Zhang, Xin [2 ]
Xie, Wanqing [4 ,6 ]
Wang, Binbin [5 ]
机构
[1] Capital Med Univ, Sch Basic Med Sci, Dept Med Genet & Dev Biol, Beijing 10069, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Heart Ctr, Natl Ctr Childrens Hlth, Beijing 10045, Peoples R China
[3] Carnegie Mellon Univ, Dept Elect & Comp Engn, Pittsburgh, PA 15232 USA
[4] Harbin Engn Univ, Coll Math Sci, Harbin, Peoples R China
[5] Natl Res Inst Family Planning, Ctr Genet, Beijing, Peoples R China
[6] Harvard Univ, Harvard Med Sch, Boston, MA 02215 USA
基金
中国国家自然科学基金;
关键词
Congenital heart disease; Multi-view learning; Multi-channel networks; Neural aggregation; PREVALENCE;
D O I
10.1016/j.media.2020.101942
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Congenital heart disease (CHD) is the most common birth defect and the leading cause of neonate death in China. Clinical diagnosis can be based on the selected 2D key-frames from five views. Limited by the availability of multi-view data, most methods have to rely on the insufficient single view analysis. This study proposes to automatically analyze the multi-view echocardiograms with a practical end-to end framework. We collect the five-view echocardiograms video records of 1308 subjects (including normal controls, ventricular septal defect (VSD) patients and atrial septal defect (ASD) patients) with both disease labels and standard-view key-frame labels. Depthwise separable convolution-based multi-channel networks are adopted to largely reduce the network parameters. We also approach the imbalanced class problem by augmenting the positive training samples. Our 2D key-frame model can diagnose CHD or negative samples with an accuracy of 95.4%, and in negative, VSD or ASD classification with an accuracy of 92.3%. To further alleviate the work of key-frame selection in real-world implementation, we propose an adaptive soft attention scheme to directly explore the raw video data. Four kinds of neural aggregation methods are systematically investigated to fuse the information of an arbitrary number of frames in a video. Moreover, with a view detection module, the system can work without the view records. Our video-based model can diagnose with an accuracy of 93.9% (binary classification), and 92.1% (3-class classification) in a collected 2D video testing set, which does not need key-frame selection and view annotation in testing. The detailed ablation study and the interpretability analysis are provided. The presented model has high diagnostic rates for VSD and ASD that can be potentially applied to the clinical practice in the future. The short-term automated machine learning process can partially replace and promote the long-term professional training of primary doctors, improving the primary diagnosis rate of CHD in China, and laying the foundation for early diagnosis and timely treatment of children with CHD. (c) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Automated Analysis of Unregistered Multi-View Mammograms With Deep Learning
    Carneiro, Gustavo
    Nascimento, Jacinto
    Bradley, Andrew P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (11) : 2355 - 2365
  • [12] Automated simultaneous calibration of a multi-view laser stripe profiler
    Stöcher, W
    Biegelbauer, G
    2005 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), VOLS 1-4, 2005, : 4424 - 4429
  • [13] Automated Multi-View Planning for Endovascular Aneurysm Repair Procedures
    Zhang, Baochang
    Liu, Yiwen
    Liu, Shuting
    Schunkert, Heribert
    Ghotbi, Reza
    Navab, Nassir
    CLINICAL IMAGE-BASED PROCEDURES, CLIP 2024, 2024, 15196 : 22 - 31
  • [14] Robust Multi-view Representation: A Unified Perspective from Multi-view Learning to Domain Adaption
    Ding, Zhengming
    Shao, Ming
    Fu, Yun
    PROCEEDINGS OF THE TWENTY-SEVENTH INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, 2018, : 5434 - 5440
  • [15] Detecting Heart Disease from Multi-View Ultrasound Images via Supervised Attention Multiple Instance Learning
    Huang, Zhe
    Wessler, Benjamin S.
    Hughes, Michael C.
    MACHINE LEARNING FOR HEALTHCARE CONFERENCE, VOL 219, 2023, 219
  • [16] Bridging the Gap from a Multi-View Modelling Method to the Design of a Multi-View Modelling Tool
    Bork, Domenik
    Sinz, Elmar J.
    ENTERPRISE MODELLING AND INFORMATION SYSTEMS ARCHITECTURES-AN INTERNATIONAL JOURNAL, 2013, 8 (02): : 25 - 41
  • [17] Automated registration of multi-view point clouds using sphere targets
    Yun, Dongho
    Kim, Sunghan
    Heo, Heeyoung
    Ko, Kwang Hee
    ADVANCED ENGINEERING INFORMATICS, 2015, 29 (04) : 930 - 939
  • [18] Real-time Planning for Automated Multi-View Drone Cinematography
    Nageli, Tobias
    Meier, Lukas
    Domahidi, Alexander
    Alonso-Mora, Javier
    Hilliges, Otmar
    ACM TRANSACTIONS ON GRAPHICS, 2017, 36 (04):
  • [19] Multi-View Image Generation from a Single-View
    Zhao, Bo
    Wu, Xiao
    Cheng, Zhi-Qi
    Liu, Hao
    Jie, Zequn
    Feng, Jiashi
    PROCEEDINGS OF THE 2018 ACM MULTIMEDIA CONFERENCE (MM'18), 2018, : 383 - 391
  • [20] Object modeling and matching from multi-view ground images for automated Mars rover localization
    Li, Ron
    Di, Kaichang
    Agarwal, Sanchit
    Wang, Jue
    Matthies, Larry
    2006 IEEE AEROSPACE CONFERENCE, VOLS 1-9, 2006, : 666 - +