Automated segmentation of intraretinal layers from macular optical coherence tomography images

被引:20
|
作者
Haeker, Mona [1 ,2 ]
Sonka, Milan [1 ,3 ]
Kardon, Randy [3 ,4 ]
Shah, Vinay A. [5 ]
Wu, Xiaodong [1 ]
Abramoff, Michael D. [1 ,3 ,4 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA USA
[3] Univ Iowa, Dept Ophthalmol & Visual Sci, Iowa City, IA USA
[4] Veterans Affairs Med Ctr, Iowa City, IA USA
[5] Univ Missouri, Dept Ophthalmol, Kansas City, MO USA
关键词
segmentation; 3-D graph search; optical coherence tomography; ophthalmology; retina;
D O I
10.1117/12.710231
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Commercially-available optical coherence tomography (OCT) systems (e.g., Stratus OCT-3) only segment and provide thickness measurements for the total retina on scans of the macula. Since each intraretinal layer may be affected differently by disease, it is desirable to quantify the properties of each layer separately. Thus, we have developed an automated segmentation approach for the separation of the retina on (anisotropic) 3-D macular OCT scans into five layers. Each macular series consisted of six linear radial scans centered at the fovea. Repeated series (up to six, when available) were acquired for each eye and were first registered and averaged together, resulting in a composite image for each angular location. The six surfaces defining the five layers were then found on each 3-D composite image series by transforming the segmentation task into that of finding a minimum-cost closed set in a geometric graph constructed from edge/regional information and a priori-determined surface smoothness and interaction constraints. The method was applied to the macular OCT scans of 12 patients with unilateral anterior ischemic optic neuropathy (corresponding to 24 3-D composite image series). The boundaries were independently defined by two human experts on one raw scan of each eye. Using the average of the experts' tracings as a reference standard resulted in an overall mean unsigned border positioning error of 6.7 +/- 4.0 mu m, with five of the six surfaces showing significantly lower mean errors than those computed between the two observers (p < 0.05, pixel size of 50 x 2 mu m).
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Denoising and Segmentation of Retinal Layers In Optical Coherence Tomography images
    Dash, Puspita
    Sigappi, A. N.
    INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, MATERIALS AND APPLIED SCIENCE, 2018, 1952
  • [22] Automated Segmentation of the Choroid in Retinal Optical Coherence Tomography Images
    Lu, Huiqi
    Boonarpha, Nattapon
    Kwong, Man Ting
    Zheng, Yalin
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5869 - 5872
  • [23] Automated Segmentation of Dental Calculus in Optical Coherence Tomography Images
    Lee, Chia-Yen
    Chuang, Ching-Cheng
    Chen, Guan-Jie
    Huang, Chih-Chia
    Lee, Shyh-Yuan
    Lin, Yu-Hsien
    SENSORS AND MATERIALS, 2018, 30 (11) : 2517 - 2529
  • [24] Macular segmentation with optical coherence tomography
    Ishikawa, H
    Stein, DM
    Wollstein, G
    Beaton, S
    Fujimoto, JG
    Schuman, JS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) : 2012 - 2017
  • [25] Microstructural Changes in Intraretinal Layers and Macular Structures of People with Epilepsy Measured Using Optical Coherence Tomography
    Cakar, Merve Melodi
    Baysal, Leyla
    Garip, Ruveyde
    Guldiken, Babuerhan
    NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2024, 61 (03): : 202 - 207
  • [26] Macular Thickness Profiles of Intraretinal Layers in Myopia Evaluated by Ultrahigh-Resolution Optical Coherence Tomography
    Liu, Xinting
    Shen, Meixiao
    Yuan, Yimin
    Huang, Shenghai
    Zhu, Dexi
    Ma, Qingkai
    Ye, Xinjie
    Lu, Fan
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (01) : 53 - 61
  • [27] Fully automated lumen segmentation of intracoronary optical coherence tomography images
    Athanasiou, L. S.
    Rikhtegar, Farhad
    Galon, Micheli Zanotti
    Lopes, Augusto Celso
    Lemos, Pedro Alves
    Edelman, Elazer R.
    MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [28] Automated Vessel Segmentation in Adaptive Optics - Optical Coherence Tomography Images
    Le, Christopher
    Wang, Dongyi
    Villanueva, Ricardo
    Liu, Zhuolin
    Hammer, Daniel
    Saeedi, Osamah
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)
  • [29] Validation of automated artificial intelligence segmentation of optical coherence tomography images
    Maloca, Peter M.
    Lee, Aaron Y.
    de Carvalho, Emanuel R.
    Okada, Mali
    Fasler, Katrin
    Leung, Irene
    Hormann, Beat
    Kaiser, Pascal
    Suter, Susanne
    Hasler, Pascal W.
    Zarranz-Ventura, Javier
    Egan, Catherine
    Heeren, Tjebo F. C.
    Balaskas, Konstantinos
    Tufail, Adnan
    Scholl, Hendrik P. N.
    PLOS ONE, 2019, 14 (08):
  • [30] Intraretinal Fluid Pattern Characterization in Optical Coherence Tomography Images
    de Moura, Joaquim
    Vidal, Placido L.
    Novo, Jorge
    Rouco, Jose
    Penedo, Manuel G.
    Ortega, Marcos
    SENSORS, 2020, 20 (07)