Pulse Wave Velocity Measurement in the Carotid Artery Using an LED-LED Array Pulse Oximeter

被引:1
|
作者
Campbell, Jake D. [1 ]
Holder-Pearson, Lui [1 ]
Pretty, Christopher G. [1 ]
Bones, Phil [2 ]
Chase, J. Geoffrey [1 ]
机构
[1] Univ Canterbury, Mech Engn Dept, Christchurch, New Zealand
[2] Univ Canterbury, Elect Engn Dept, Christchurch, New Zealand
来源
IFAC PAPERSONLINE | 2020年 / 53卷 / 02期
基金
欧盟地平线“2020”;
关键词
Pulse wave velocity; non-invasive; photoplethysmography; LED-LED detection; carotid artery; STIFFNESS;
D O I
10.1016/j.ifacol.2020.12.406
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Pulse wave velocity (PWV) is frequently used as an early indicator of risk of cardiovascular disease. Conventional methods of PWV measurement are invasive and measure the regional PWV, introducing errors from unknown measurement distance to masking local changes in compliance. This paper describes the development and testing of a non-invasive PWV sensor using photoplethysmograph signals. The sensor measures the pulse in the carotid artery with three sensor arrays spaced at 20 mm, 30 mm and 50 mm spacing. Each array of 20 LED-LED sensors are placed at 5 mm to get the largest amplitude pulse across the neck, and to allow for inaccurate sensor placement. LEDs are used as light emitters and the inherent capacitance of reverse biased LEDs measure the reflected light. The foot-foot and phase difference methods were used to calculate the PWV at each measurement distance. The foot-foot method was more reliable than the phase difference at all distances with a PWV of 5.26 ms(-1) in a single-subject trial. The sample rate of 570 Hz was deemed too slow as one sample difference resulted in a PWV change of 1.5 m s(-1). The developed sensor measured the local PWV within the expected physiological range around 6 m s(-1). All future measurements will be measured at 1 kHz and an increased LED output intensity. Copyright (C) 2020 The Authors.
引用
收藏
页码:16031 / 16036
页数:6
相关论文
共 50 条
  • [21] Carotid to Femoral Pulse Wave Velocity Reflects the Extent of Coronary Artery Disease
    Hofmann, Britt
    Riemer, Marcus
    Erbs, Christian
    Plehn, Alexander
    Santos, Alexander Navarrete
    Wienke, Andreas
    Silber, Rolf-Edgar
    Simm, Andreas
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (09): : 629 - 633
  • [22] Local carotid artery pulse wave velocity: foot to foot or dicrotic notch?
    Muiesan, Maria Lorenza
    Paini, Anna
    JOURNAL OF HYPERTENSION, 2009, 27 (10) : 1962 - 1963
  • [23] Analysis of Pulse Waveform and Pulse Wave Velocity of Carotid Artery and Radial Artery by Using Clip-type Pulsimeter Equipped with Permanent and Hall Device
    Kim, Dong-Young
    Lee, Sang-Suk
    Hyeon, Seog-San
    Rhee, Jin-Kyu
    JOURNAL OF THE KOREAN MAGNETICS SOCIETY, 2014, 24 (05): : 146 - 151
  • [24] Contactless Carotid Pulse Measurement Using Continuous Wave Radar
    Shi, Kilin
    Schellenberger, Sven
    Steigleder, Tobias
    Michler, Fabian
    Lurz, Fabian
    Weigel, Robert
    Koelpin, Alexander
    2018 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC), 2018, : 569 - 571
  • [25] Ultrasound Ultrafast Imaging of the Carotid Artery Pulse Wave Velocity: Is the Surrogate of Regional Artery Stiffness?
    Zhang, Li
    Fang, Lingyun
    Zhang, Dan
    Xiang, Feixiang
    Song, Yue
    Xie, Mingxing
    CIRCULATION, 2019, 140
  • [26] Ultrasound Ultrafast Imaging of the Carotid Artery Pulse Wave Velocity: is the Surrogate of Regional Artery Stiffness?
    Fang, Lingyun
    Zhang, Dan
    Wang, Jing
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2018, 38
  • [27] Evaluation of carotid artery elastic function using ultrafast pulse wave velocity in patients with rheumatoid arthritis
    Li, Yihan
    Zhang, Jian
    An, Xin
    Li, Yuhong
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2022, 39 (04): : 552 - 560
  • [28] Pulse Wave Velocity Doppler Measurement of Ulnar Artery Using a High-Frequency Probe
    Benchemoul, Maxime
    Savery, David
    Gehin, Claudine
    Massot, Bertrand
    Ferin, Guillaume
    Vince, Philippe
    Flesch, Martin
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [29] Measurement of pulse wave velocity using magnetic resonance imaging
    Gang, G
    Mark, P
    Cockshott, P
    Foster, J
    Martin, T
    Blyth, K
    Steedman, T
    Elliott, A
    Dargie, H
    Groenning, B
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 3684 - 3687
  • [30] Validation of a piezoelectric sensor array based device for measurement of carotid-femoral pulse wave velocity: the Philips Prototype
    Xu, Shaokun
    Wang, Jiguang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C189 - C189