A review of artificial contamination withstand test methods of high voltage outdoor insulators

被引:7
|
作者
Naderian, A [1 ]
Sanaye-Pasand, M [1 ]
Mohseni, H [1 ]
机构
[1] Univ Tehran, ECE Dept, Tehran, Iran
关键词
D O I
10.1109/ELINSL.2004.1380559
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper several important test methods for artificially polluted ceramic and non-ceramic insulators have been reviewed. There is no standard test for non-ceramic insulators. The research has shown that it is necessary to modify the standard 5000h salt fog test to evaluate the long-term performance of non-ceramic insulators. Although the main parameter for selection of proper ceramic and glass insulators is the amount of pollution, it seems to be necessary to consider other environmental factors for selection of composite insulators. These are average humidity, UV radiation level, wind velocity, rain fall, and dominant type of wetting. This is necessary because research has shown that they directly effect the performance,of non-ceramic insulators.
引用
收藏
页码:284 / 287
页数:4
相关论文
共 50 条
  • [21] Study on Artificial Contamination Test of Typical Transmission Line Insulators
    Gu, Chunhui
    Lu, Guojun
    Yi, Mancheng
    Li, Jiangtao
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1624 - 1627
  • [22] Artificial intelligence assessment of sea salt contamination of medium voltage insulators
    Oikonomou, D. S.
    Maris, T. I.
    Ekonomou, L.
    PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON SYSTEMS THEORY AND SCIENTIFIC COMPUTATION (ISTAC'08), 2008, : 319 - 323
  • [23] Modified silicone rubber for use as high voltage outdoor insulators
    Ehsani, M
    ADVANCES IN POLYMER TECHNOLOGY, 2005, 24 (01) : 51 - 61
  • [24] Performance of novel high voltage outdoor thermoplastic elastomeric insulators
    Soundarajan, E
    Jackson, E
    King, A
    Sundararajan, R
    2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 422 - 425
  • [25] Performance Evaluation of Outdoor High Voltage Glass Insulators in High Pollution Industrial Areas Using Simulated Acid Rain Contamination
    Ilomuanya, Chibuike
    Farokhi, Shahab
    Nekahi, Azam
    IEEE ACCESS, 2022, 10 : 80600 - 80608
  • [26] Analysis of Leakage Current of Long String Insulators of High-Altitude Artificial Contamination Test
    Liu, Qin
    Wan, Xiaodong
    Xu, Tao
    Nan, Jing
    Xu, Zuoming
    2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 303 - 307
  • [27] Leakage current test and study of room temperature vulcanizing coatings for outdoor high voltage porcelain insulators
    Wang, NC
    Chi, CF
    Guo, TY
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1495 - 1500
  • [28] Dimensional Analysis for Contamination Severity Assessment on High Voltage Insulators
    Ahmad, S. Ahmad
    Ahmed, Saad
    Ahmed, S. Shahnawaz
    ICIAS 2007: INTERNATIONAL CONFERENCE ON INTELLIGENT & ADVANCED SYSTEMS, VOLS 1-3, PROCEEDINGS, 2007, : 893 - +
  • [29] Contamination of high voltage insulators in the east coast of peninsular Malaysia
    Ahmad, AS
    Ahmad, H
    Jidin, RB
    Tamsir, T
    Ahmed, SS
    Buntat, Z
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1223 - 1228
  • [30] NATURAL CONTAMINATION TEST OF INSULATORS WITH DC-VOLTAGE ENERGIZATION AT INLAND AREAS
    TAKASU, K
    SHINDO, T
    ARAI, N
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1847 - 1853