Manual closed-loop insulin delivery in children and adolescents with type 1 diabetes: a phase 2 randomised crossover trial

被引:296
|
作者
Hovorka, Roman [1 ,2 ]
Allen, Janet M. [1 ,2 ]
Elleri, Daniela [1 ,2 ]
Chassin, Ludovic J. [1 ,2 ]
Harris, Julie [2 ]
Xing, Dongyuan [3 ]
Kollman, Craig [3 ]
Hovorka, Tomas [1 ]
Larsen, Anne Mette F. [1 ,2 ]
Nodale, Marianna [1 ]
De Palma, Alessandro [1 ]
Wilinska, Malgorzata E. [1 ,2 ]
Acerini, Carlo L. [1 ,2 ]
Dunger, David B. [1 ,2 ]
机构
[1] Univ Cambridge, Dept Paediat, Cambridge CB2 0QQ, England
[2] Univ Cambridge, Inst Metab Sci, Cambridge CB2 0QQ, England
[3] Jaeb Ctr Hlth Res, Tampa, FL USA
来源
LANCET | 2010年 / 375卷 / 9716期
基金
英国医学研究理事会; 英国惠康基金;
关键词
SEVERE HYPOGLYCEMIA; GLUCOSE; ROADMAP;
D O I
10.1016/S0140-6736(09)61998-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Closed-loop systems link continuous glucose measurements to insulin delivery. We aimed to establish whether closed-loop insulin delivery could control overnight blood glucose in young people. Methods We undertook three randomised crossover studies in 19 patients aged 5-18 years with type 1 diabetes of duration 6.4 years (SD 4.0). We compared standard continuous subcutaneous insulin infusion and closed-loop delivery (n=13; APCam01); closed-loop delivery after rapidly and slowly absorbed meals (n=7; APCam02); and closed-loop delivery and standard treatment after exercise (n=10; APCam03). Allocation was by computer-generated random code. Participants were masked to plasma and sensor glucose. In APCam01, investigators were masked to plasma glucose. During closed-loop nights, glucose measurements were fed every 15 min into a control algorithm calculating rate of insulin infusion, and a nurse adjusted the insulin pump. During control nights, patients' standard pump settings were applied. Primary outcomes were time for which plasma glucose concentration was 3.91-8.00 mmol/L or 3.90 mmol/L or lower. Analysis was per protocol. This trial is registered, number ISRCTN18155883. Findings 17 patients were studied for 33 closed-loop and 21 continuous infusion nights. Primary outcomes did not differ significantly between treatment groups in APCam01 (12 analysed; target range, median 52% [IQR. 43-83] closed loop vs 39% [15-51] standard treatment, p=0.06; <= 3.90 mmol/L, 1% [0-7] vs 2% [0-41], p=0.13), APCam02 (six analysed; target range, rapidly 53% [48-57] vs slowly absorbed meal 55% [37-64], p=0.97; <= 3.90 mmol/L, 0% [0-4] vs 0% [0-0], p=0.16]), and APCam03 (nine analysed; target range 78% [60-92] closed loop vs 43% [25-65] control, p=0.0245, not significant at corrected level; <= 3.90 mmol/L, 10% [2-15] vs 6% [0-44], p=0.27). A secondary analysis of pooled data documented increased time in the target range (60% [51-88] vs 40% [18-61]; p=0.0022) and reduced time for which glucose concentrations were 3.90 mmol/L or lower (2.1% (0.0-10.0) vs 4.1% (0.0-42.0); p=0.0304). No events with plasma glucose concentration lower than 3.0 mmol/L were recorded during closed-loop delivery compared with nine events during standard treatment. Interpretation Closed-loop systems could reduce risk of nocturnal hypoglycaemia in children and adolescents with type 1 diabetes.
引用
收藏
页码:743 / 751
页数:9
相关论文
共 50 条
  • [31] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Vikash Dadlani
    Jordan E. Pinsker
    Eyal Dassau
    Yogish C. Kudva
    Current Diabetes Reports, 2018, 18
  • [32] Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes
    Murphy, Helen R.
    Eller, Daniela
    Allen, Janet M.
    Harris, Julie
    Simmons, David
    Rayman, Gerry
    Temple, Rosemary
    Dunger, David B.
    Haidar, Ahmad
    Nodale, Marianna
    Wilinska, Malgorzata E.
    Hovorka, Roman
    DIABETES CARE, 2011, 34 (02) : 406 - 411
  • [33] Closed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes
    Stewart, Zoe A.
    Wilinska, Malgorzata E.
    Hartnell, Sara
    Temple, Rosemary C.
    Rayman, Gerry
    Stanley, Katharine P.
    Simmons, David
    Law, Graham R.
    Scott, Eleanor M.
    Hovorka, Roman
    Murphy, Helen R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (07): : 644 - 654
  • [34] Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes
    Dadlani, Vikash
    Pinsker, Jordan E.
    Dassau, Eyal
    Kudva, Yogish C.
    CURRENT DIABETES REPORTS, 2018, 18 (10)
  • [35] A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
    Breton, Marc D.
    Kanapka, Lauren G.
    Beck, Roy W.
    Ekhlaspour, Laya
    Forlenza, Gregory P.
    Cengiz, Eda
    Schoelwer, Melissa
    Ruedy, Katrina J.
    Jost, Emily
    Carria, Lori
    Emory, Emma
    Hsu, Liana J.
    Oliveri, Mary
    Kollman, Craig C.
    Dokken, Betsy B.
    Weinzimer, Stuart A.
    DeBoer, Mark D.
    Buckingham, Bruce A.
    Chernavvsky, Daniel
    Wadwa, R. Paul
    NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (09): : 836 - 845
  • [36] Fully automated closed-loop insulin delivery vs standard insulin therapy in adults with type 2 diabetes: an open-label, single-centre randomised crossover trial
    Boughton, C. K.
    Daly, A. B.
    Nwokolo, M.
    Hartnell, S.
    Wilinska, M. E.
    Cezar, A.
    Evans, M. L.
    Hovorka, R.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S27 - S27
  • [37] Effect of 6 months hybrid closed-loop insulin delivery in young people with type 1 diabetes: a randomised controlled trial protocol
    de Bock, Martin
    McAuley, Sybil A.
    Abraham, Mary Binsu
    Smith, Grant
    Nicholas, Jennifer
    Ambler, Geoff R.
    Cameron, Fergus J.
    Fairchild, Jan M.
    King, Bruce R.
    Geelhoed, Elizabeth A.
    Davis, Elizabeth A.
    O'Neal, David Norman
    Jones, Timothy W.
    BMJ OPEN, 2018, 8 (08):
  • [39] Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies
    Hovorka, Roman
    Kumareswaran, Kavita
    Harris, Julie
    Allen, Janet M.
    Elleri, Daniela
    Xing, Dongyuan
    Kollman, Craig
    Nodale, Marianna
    Murphy, Helen R.
    Dunger, David B.
    Amiel, Stephanie A.
    Heller, Simon R.
    Wilinska, Malgorzata E.
    Evans, Mark L.
    BMJ-BRITISH MEDICAL JOURNAL, 2011, 342
  • [40] Efficacy and safety of reduced prandial boluses during closed-loop insulin delivery in adolescents with type 1 diabetes
    Elleri, D.
    Allen, J. M.
    Biagioni, M.
    Kumareswaran, K.
    Leelarathna, L.
    Caldwell, K.
    Nodale, M.
    Wilinska, M. E.
    Haidar, A.
    Calhoun, P.
    Kollman, C.
    Umpleby, M. A.
    Acerini, C. L.
    Dunger, D. B.
    Hovorka, R.
    DIABETOLOGIA, 2012, 55 : S86 - S87