Behaviour of End-Plate Connections in 3D Frames Under Fire Conditions: Experimental Study

被引:3
|
作者
Khonsari, S., V [1 ]
Grayli, P. Vosough [1 ]
Ghorbani, A. [1 ]
Moghaddam, A. Roshani [1 ]
机构
[1] Sharif Univ Technol, Dept Civil Engn, Tehran, Iran
关键词
3D steel frames; Half-scale model; Flush end-plate connections; Elevated temperatures; Fire; Distributed loading;
D O I
10.1007/s13296-018-0027-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to high vulnerability of steel structures to elevated temperatures and the need for taking adequate and effective measures to reduce human and financial losses in fires, a thorough understanding of such behaviour is of utmost importance. In this research, a half-scale 3D model, comprising moment-resisting frames, equipped with flush end-plate connections, in one direction, and braced frames in the other, was subjected to a scaled ISO 834 standard fire. The maximum attained temperature was 1055 degrees C. The results showed that the structure tolerates high temperatures for an appreciable amount of time before collapsing. Moreover, for thick flush end-plates, which were used in this study, the collapse was initiated by bolt failure, giving rise to the idea of using more/stronger bolts and weaker end-plates to delay the overall collapse of the structure.
引用
收藏
页码:734 / 749
页数:16
相关论文
共 50 条
  • [41] Experimental Database for Steel Flush End-Plate Connections
    Mak, Lam
    Elkady, Ahmed
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (07)
  • [42] Warping transfer superelement model for bolted end-plate connections subject to 3D loads
    Vaszilievits-Somjen, B.
    Szalai, J.
    Movahedi, R. M.
    STABILITY AND DUCTILITY OF STEEL STRUCTURES 2019, 2019, : 1210 - 1217
  • [43] Numerical studies on the structural behaviour of composite end-plate connections
    Wang, Aaron J.
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2010, 37 (06) : 907 - 921
  • [44] Experimental and numerical study on behaviour of extended end-plate connections with Q960 steel at elevated temperature
    Wang, Weiyong
    Qian, Zhenghao
    Zhang, Yifa
    Wang, Zhiruoyu
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 213
  • [45] Unsymmetric bolted end-plate moment connections in earthquake conditions
    Beg, D
    Skuber, P
    Remec, C
    ADVANCES IN STRUCTURAL DYNAMICS, VOLS I & II, 2000, 10 : 801 - 808
  • [46] Experimental and theoretical analysis of the moment-rotation behaviour of stiffened extended end-plate connections
    Shi, Yongjiu
    Shi, Gang
    Wang, Yuanqing
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2007, 63 (09) : 1279 - 1293
  • [47] BEHAVIOUR OF END-PLATE STEEL CONNECTIONS WITH 4 BOLTS PER ROW UNDER LARGE DEFORMATIONS
    Nunes, D. L.
    Ciutina, A.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 399 - 410
  • [48] FINITE ELEMENT ANALYSIS OF CYCLIC LOADING BEHAVIOUR OF END-PLATE CONNECTIONS
    Shi, Gang
    Fan, Hao
    Shi, Yong-Jiu
    Wang, Yuan-Qing
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 382 - 387
  • [49] Finite element analysis of the cyclic behaviour of steel end-plate connections
    Nemati, N
    Le Houedec, D
    Zandonini, R
    INNOVATION IN ENGINEERING FOR SEISMIC REGIONS, 1997, : 89 - 102
  • [50] Ultimate behaviour and rotation capacity of stainless steel end-plate connections
    Song, Yuchen
    Uy, Brian
    Li, Dongxu
    Wang, Jia
    STEEL AND COMPOSITE STRUCTURES, 2022, 42 (04): : 569 - 590