The effect of acetabular and femoral component version on dislocation in primary total hip arthroplasty

被引:37
|
作者
Fujishiro, Takaaki [1 ,2 ,3 ]
Hiranaka, Takafumi [2 ,3 ]
Hashimoto, Shingo [1 ]
Hayashi, Shinya [1 ]
Kurosaka, Masahiro [1 ]
Kanno, Taiki [4 ]
Masuda, Takeshi [4 ]
机构
[1] Kobe Univ, Grad Sch Med, Dept Orthopaed Surg, Chuo Ku, 7-5-1 Kusunoki Cho, Kobe, Hyogo 6500017, Japan
[2] Takatsuki Gen Hosp, Dept Orthopaed Surg, 1-3-13 Kosobe Cho, Takatsuki, Osaka 5691192, Japan
[3] Takatsuki Gen Hosp, Joint Surg Ctr, 1-3-13 Kosobe Cho, Takatsuki, Osaka 5691192, Japan
[4] Eniwa Hosp, Dept Orthopaed Surg, 2-1-1 Kogane Chuo, Eniwa, Hokkaido 0611449, Japan
关键词
Total hip arthroplasty; Dislocation; Computed tomography; Component version; REPLACEMENT ARTHROPLASTIES; DEVELOPMENTAL DYSPLASIA; COMBINED ANTEVERSION; FOLLOW-UP; RISK; ORIENTATION; CUP; CT;
D O I
10.1007/s00264-015-2924-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the present study was to: (1) investigate the variation of both acetabular and femoral component version in a large series of consecutive primary THA patients, and (2) to better define the associations of acetabular and femoral component alignment and clinical factors with subsequent hip dislocation in those patients. We analyzed CT scans of 1,555 consecutive primary THAs and measured version of the components. We also documented the frequency and direction of subsequent dislocation as well as femoral head size, posterior tissue repair, any history of previous hip surgery, and gender. The dislocation rate after THA was 3.22 %. The dislocation risk was 1.9 times higher if cup anteversion was not between 10A degrees and 30A degrees. Compared to hips that did not dislocate, those that experienced anterior dislocation had a significantly greater combined anteversion; those that dislocated posteriorly had a significantly smaller combined anteversion. Hips with previous rotational acetabular osteotomy or head size smaller than 28 mm correlated with an increased dislocation rate. The dislocation risk could be higher if cup anteversion was not between 10A degrees and 30A degrees. Greater combined anteversion could be a risk factor of anterior dislocation, and posterior dislocation could be more common in smaller combined anteversion.
引用
收藏
页码:697 / 702
页数:6
相关论文
共 50 条
  • [41] ACETABULAR COMPONENT ORIENTATION IN TOTAL HIP ARTHROPLASTY: THE ROLE OF ACETABULAR TRANSVERSE LIGAMENT
    El Idrissi, Mohammed
    Elibrahimi, Abdelhalim
    Shimi, Mohammed
    Elmrini, Abdelmajid
    Acta Ortopedica Brasileira, 2016, 24 (05): : 267 - 269
  • [42] Femoral fixation in primary total hip arthroplasty
    Engh, CA
    Culpepper, WJ
    ORTHOPEDICS, 1997, 20 (09) : 771 - 773
  • [43] Effects of acetabular component orientation on dislocation propensity for small-head-size total hip arthroplasty
    Nadzadi, ME
    Pedersen, DR
    Callaghan, JJ
    Brown, TD
    CLINICAL BIOMECHANICS, 2002, 17 (01) : 32 - 40
  • [44] Per-acetabular dislocation of a Harris-Galante total hip arthroplasty secondary to component failure
    Sfeir, Patrick R.
    Edmondson, Mark C.
    Armitage, Andrew R.
    Skyrme, Andrew. D.
    Zicat, Bernard. A.
    AMERICAN JOURNAL OF CASE REPORTS, 2010, 11 : 70 - 73
  • [45] CEMENTLESS FIXATION OF THE ACETABULAR COMPONENT IN TOTAL HIP-ARTHROPLASTY
    DEKLERK, AJ
    BOMBELLI, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (03): : 447 - 447
  • [46] Acetabular component orientation in total hip arthroplasty: the impact of obesity
    McArthur, Benjamin A.
    Vulcano, Ettore
    Cross, Michael
    Nguyen, Joseph
    Della Valle, Alejandro G.
    Salvati, Eduardo
    HIP INTERNATIONAL, 2014, 24 (03) : 263 - 269
  • [47] Catastrophic failure and metallosis of the acetabular component in total hip arthroplasty
    Ozan, Firat
    Kahraman, Murat
    Baktir, Ali
    Gencer, Kursat
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [48] The influence of acetabular component position on wear in total hip arthroplasty
    Wan, Zhinian
    Boutary, Myriam
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 51 - 56
  • [49] Total hip arthroplasty with the use of nonmodular cementless acetabular component
    Kim, SY
    Kim, DH
    Oh, CW
    Kim, PT
    Ihn, JC
    Kim, SY
    JOURNAL OF ARTHROPLASTY, 2005, 20 (05): : 632 - 638
  • [50] Spinopelvic mobility and acetabular component position for total hip arthroplasty
    Stefl, M.
    Lundergan, W.
    Heckmann, N.
    McKnight, B.
    Ike, H.
    Murgai, R.
    Dorr, L. D.
    BONE & JOINT JOURNAL, 2017, 99B (01): : 37 - 45