Reliability of a portable gas analyzer during a 5-min walk test

被引:3
|
作者
da Cunha-Filho, Inacio Teixeira
Henson, Helene
Protas, Elizabeth J.
机构
[1] Ctr Univ Belo Horizonte, Belo Horizonte, MG, Brazil
[2] Michael E DeBakey VA Med Ctr, Dept Phys Med & Rehabil, Houston, TX USA
[3] Michael E DeBakey VA Med Ctr, Rehabil Res & Dev Ctr Excellence Healthy Aging Di, Houston, TX USA
[4] Baylor Coll Med, Houston, TX 77030 USA
[5] Univ Texas, Med Branch, Dept Phys Therapy, Galveston, TX 77550 USA
关键词
oxygen consumption; gait; reliability; walking;
D O I
10.1097/PHM.0b013e31805b9505
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine the reliability of a gas analyzer while assessing oxygen consumption (VO2) during a 5-min walking test. Design: Forty healthy participants were connected to the KB 1 -C and walked for 5 mins on a 5-m walkway. TotalVO(2) or energy expenditure (EE) was obtained by averaging the samples for each minute for 5 mins of walking. Walk distance (D), gait speed (S), and gait energy cost (C) were also evaluated. Results: The ICC2,1 for EE, D, S, and C were 0.88, 0.92, 0.92, and 0.67, respectively. The coefficient of variation across trials for each variable was 7.4, 3.6, 3.2, and 9%, respectively. Conclusion: All but C generated high coefficients of reliability. All variables demonstrated acceptable test-retest variability. There was low variability between participants for C.
引用
收藏
页码:469 / 473
页数:5
相关论文
共 50 条
  • [1] VALIDATION OF 5-MIN RUNNING TEST IN PREDICTING AEROBIC CAPACITY
    Lin, H. F.
    Lin, J. C.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S23 - S23
  • [2] Reliability of the 5-min psychomotor vigilance task in a primary school classroom setting
    Wilson, Andrew
    Dollman, James
    Lushington, Kurt
    Olds, Timothy
    BEHAVIOR RESEARCH METHODS, 2010, 42 (03) : 754 - 758
  • [3] A 5-min running field test as a measurement of maximal aerobic velocity
    Paul Berthon
    Nicole Fellmann
    Mario Bedu
    B. Beaune
    Michel Dabonneville
    Jean Coudert
    Alain Chamoux
    European Journal of Applied Physiology and Occupational Physiology, 1997, 75 : 233 - 238
  • [4] A 5-min running field test as a measurement of maximal aerobic velocity
    Berthon, P
    Fellmann, N
    Bedu, M
    Beaune, B
    Dabonneville, M
    Coudert, J
    Chamoux, A
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1997, 75 (03) : 233 - 238
  • [5] Reliability of the 5-min psychomotor vigilance task in a primary school classroom setting
    Andrew Wilson
    James Dollman
    Kurt Lushington
    Timothy Olds
    Behavior Research Methods, 2010, 42 : 754 - 758
  • [6] Reliability of the 5-min speech sample for assessing expressed emotion in Japanese patients
    Uehara, T
    Yokoyama, T
    Goto, M
    Nakano, Y
    Kawashima, Y
    Someya, T
    PSYCHIATRY AND CLINICAL NEUROSCIENCES, 1999, 53 (04) : 511 - 514
  • [7] Reliability of a 5-min running field test and its accuracy in (V)over-dot-O2max evaluation
    Tong, TK
    Fu, FH
    Chow, BC
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2001, 41 (03): : 318 - 323
  • [8] Reliability of the 6-min walk test after total knee arthroplasty
    Thomas Linding Jakobsen
    Henrik Kehlet
    Thomas Bandholm
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2625 - 2628
  • [9] Reliability of the 6-min walk test after total knee arthroplasty
    Jakobsen, Thomas Linding
    Kehlet, Henrik
    Bandholm, Thomas
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (11) : 2625 - 2628
  • [10] Test-retest reliability of the 6-min walk test in patients with postpolio syndrome
    Skough, Katarina
    Broman, Lisbet
    Borg, Kristian
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2013, 36 (02) : 140 - 145