Changes in anterior chamber eye during accommodation as assessed using a Dual Scheimpflug system

被引:9
|
作者
Dominguez-Vicent, Alberto [1 ]
Monsalvez-Romin, Daniel [1 ]
Albarran-Diego, Cesar [1 ]
Sanchis-Jurado, Vicent [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, Optometry Res Grp GIO, E-46100 Burjassot, Spain
基金
欧洲研究理事会;
关键词
Anterior chamber; Pupil; Accommodation; ocular; Techniques; measures; measurement equipment; OPTICAL COHERENCE TOMOGRAPHY; CRYSTALLINE LENS; INTRAOCULAR-LENS; SEGMENT CHANGES; BIOMETRY; DEPTH; DIMENSIONS; REFRACTION; MOVEMENT; YOUNG;
D O I
10.5935/0004-2749.20140062
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the changes in anterior chamber depth (ACD), anterior chamber angle (ACA), and pupil diameter (PD) during accommodation. Methods: Eighty eyes of 80 subjects, aged 22 to 40 years, were included. The rotating Dual Scheimpflug and a Placido disc system (Galilei G4, Ziemer Ophthalmic Systems AG, Switzerland) was used to measure the changes in ACD, ACA, and PD during accommodation. ACD measurement was taken for the central zone and for 4 more positions, each in different orientation (nasal, superior, temporal and inferior), 4 mm away from the centre. ACA was measured for the whole eye as well for the nasal, superior, temporal, and inferior quadrants. These metrics were obtained for various accommodation stimuli, ranging from + 1 D to -4 D in 1-D steps. Results: For a given position, the ACD did not vary significantly with accommodation. For the central ACD, the percentage of relative change between far and near vision was -4.11%. The ACA was significantly lower at the inferior, temporal, and superior positions. There was no change in the ACA of the whole eye and that of the nasal orientation. These two eye metrics were significantly lower in the superior-nasal than in the inferior-temporal region. At each vergence studied, the PD decreased significantly with accommodation. The relative change after the -4 D stimulus was -8.13%. Conclusion: ACA and PD varied significantly with accommodation, whereas no such variation of ACD was observed. Further, the anterior chamber was found to be asymmetrical, with the nasal-superior area becoming significantly shallower than the inferior temporal region.
引用
收藏
页码:243 / 249
页数:7
相关论文
共 50 条
  • [21] Influences of Topical Cyclopentolate on Anterior Chamber Parameters With a Dual-Scheimpflug Analyzer in Healthy Children
    Guler, Emre
    Guragac, Fatma Betul
    Tenlik, Aylin
    Yagci, Ramazan
    Arslanyilmaz, Zeynel
    Balci, Mehmet
    JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2015, 52 (01) : 26 - 30
  • [22] Comparison of Anterior Chamber Depth of Normal and Keratoconus Eyes Using Scheimpflug Photography
    Edmonds, Charles R.
    Wung, Shu-Fen
    Pemberton, Bart
    Surrett, Steven
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2009, 35 (03): : 120 - 122
  • [23] ANTERIOR-CHAMBER PACHYMETRY DURING ACCOMMODATION IN EMMETROPIC AND MYOPIC EYES
    RABIE, EP
    STEELE, C
    DAVIES, EG
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1986, 6 (03) : 283 - 286
  • [24] Descriptive analysis of corneal maps and anterior segment tomography of the rabbit eye using dual Scheimpflug and Placido Disc tomography
    Ramos, Leticia de Andrade
    Arce, Carlos Guillermo
    Brandao, Claudia Valeria Seullner
    Goncalves, Lenise Garbelotti
    Padovani, Carlos Roberto
    CIENCIA RURAL, 2025, 55 (06):
  • [25] CONTUSION-PRODUCED CHANGES IN ANTERIOR CHAMBER ANGLE OF EYE
    PARFENOV, IS
    VESTNIK OFTALMOLOGII, 1974, (01) : 25 - 27
  • [26] CHANGES IN THE KARYOTYPIC STRUCTURE OF MURINE AND RAT RHABDOMYOSARCOMAS DURING THEIR TRANSPLANTATION INTO THE EYE ANTERIOR-CHAMBER
    STEPANYAN, LI
    GRYGORIEVA, EG
    SANCHAKOVA, EV
    SHVEMBERGER, IN
    TSITOLOGIYA, 1979, 21 (09): : 1074 - 1080
  • [27] Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer
    Bu Ki Kim
    Su Joung Mun
    Young Hoon Yang
    Ji Sun Kim
    Jun Hyung Moon
    Young Taek Chung
    BMC Ophthalmology, 19
  • [28] Comparison of anterior segment changes after femtosecond laser LASIK and SMILE using a dual rotating Scheimpflug analyzer
    Kim, Bu Ki
    Mun, Su Joung
    Yang, Young Hoon
    Kim, Ji Sun
    Moon, Jun Hyung
    Chung, Young Taek
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [29] Comparison of anterior chamber depth measurements of Nidek AL-Scan and Galilei Dual Scheimpflug Analyzer
    Dervisogullari, Mehmet Serdar
    Totan, Yuksel
    Guragac, Betul
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02): : 85 - 88
  • [30] Ultrasound biomicroscopy of the anterior segment of the enucleated chicken eye during accommodation
    Choh, V
    Sivak, JG
    Irving, EL
    Wong, W
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2002, 22 (05) : 401 - 408