Low-dose interpolated average CT for attenuation correction in cardiac PET/CT

被引:6
|
作者
Wu, Tung-Hsin [4 ]
Zhang, Geoffrey [3 ]
Wang, Shyh-Jen [2 ,4 ]
Chen, Chih-Hao [2 ]
Yang, Bang-Hung [2 ,4 ]
Wu, Nien-Yun [2 ]
Huang, Tzung-Chi [1 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
[2] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[3] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL USA
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
关键词
Attenuation correction; Cine CT; Deformable image registration; PET; OPTICAL-FLOW; IMAGES;
D O I
10.1016/j.nima.2009.11.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Because of the advantages in the use of high photon flux and thus the short scan times of CT imaging, the traditional Ge-68 scans for positron emission tomography (PET) image attenuation correction have been replaced by CT scans in the modern PET/CT technology. The combination of fast CT scan and slow PET scan often causes image misalignment between the PET and CT images due to respiration motion. Use of the average CT derived from cine CT images is reported to reduce such misalignment. However, the radiation dose to patients is higher with cine CT scans. This study introduces a method that uses breath-hold CT images and their interpolations to generate the average CT for PET image attenuation correction. Breath-hold CT sets are taken at end-inspiration and end-expiration. Deformable image registration is applied to generate a voxel-to-voxel motion matrix between the two CT sets. The motion is equally divided into 5 steps from inspiration to expiration and 5 steps from expiration to inspiration, generating a total of 8 phases of interpolated CT sets. An average CT image is generated from all the 10 phase CT images, including original inhale/exhale CT and 8 interpolated CT sets. Quantitative comparison shows that the reduction of image misalignment artifacts using the average CT from the interpolation technique for PET attenuation correction is at a similar level as that using cine average CT, while the dose to the patient from the CT scans is reduced significantly. The interpolated average CT method hence provides a low dose alternative to cine CT scans for PET attenuation correction. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [31] Effect of the dose reduction applied low dose for PET/CT according to CT attenuation correction method
    Jeong, Seung Woo
    Kim, Hong Gyun
    Gwon, Jae Beom
    Shin, Young Man
    Kim, Yeong Heon
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [32] Effect of the dose reduction applied low dose for PET/CT according to CT attenuation correction method
    Jeong, Seung Woo
    Kim, Hong Gyun
    Gwon, Jae Beom
    Shin, Young Man
    Kim, Yeong Heon
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [33] Low-dose cardiac CT
    Ferreira, Antonio Miguel
    Lopes, Ricardo
    Correia, Maria da Graca
    Gil, Victor
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2010, 29 (03) : 459 - 462
  • [34] Low dose CT for attenuation correction of LAFOV PET body imaging
    Willson, T.
    Natarajan, H.
    Khan, J.
    McCool, D.
    Holman, B. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S705 - S705
  • [35] Interpolated CT for attenuation correction on respiratory gating cardiac SPECT/CT - A simulation study
    Zhang, Duo
    Ghaly, Michael
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2019, 46 (06) : 2621 - 2628
  • [36] Usefulness of CT iterative reconstruction method for low-dose CT attenuation correction on the accuracy of PET image in obesity phantom study
    Matsutomo, Norikazu
    Onishi, Hideo
    Nagaki, Akio
    Matsumoto, Keiichi
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54
  • [37] Optimization and evaluation of low dose CT protocol for attenuation correction of PET data
    Mojabi, Z.
    Ghafarian, P.
    Ghadiri, H.
    Bakhshayeshkaram, M.
    Jamaati, H.
    Ay, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S486 - S487
  • [38] Automatic Registration of Cardiac PET/CT for Attenuation Correction
    Bond, Sarah
    Kadir, Timor
    Hamill, James
    Casey, Michael
    Platsch, Guenther
    Burckhardt, Darrell
    Eisner, Robert
    Kaustubh, Navin
    Declerck, Jerome
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4785 - +
  • [39] Quantitative Imaging with Low-dose CT in the PET/CT System
    Nam, Sora
    Kim, Hee-Joung
    Yu, A-Ram
    Cho, Hyo-Min
    Lee, Chang-Lae
    Park, Hye-Suk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 55 (04) : 1626 - 1631
  • [40] Quantitative imaging with low-dose CT in the PET/CT system
    Nam, Sora
    Kim, Hee-Joung
    Jung, Ji young
    Cho, Hyo-Min
    Le, Chang-Lae
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3436 - 3439