Low-dose interpolated average CT for attenuation correction in cardiac PET/CT

被引:6
|
作者
Wu, Tung-Hsin [4 ]
Zhang, Geoffrey [3 ]
Wang, Shyh-Jen [2 ,4 ]
Chen, Chih-Hao [2 ]
Yang, Bang-Hung [2 ,4 ]
Wu, Nien-Yun [2 ]
Huang, Tzung-Chi [1 ]
机构
[1] China Med Univ, Dept Biomed Imaging & Radiol Sci, Taichung, Taiwan
[2] Taipei Vet Gen Hosp, Dept Nucl Med, Taipei, Taiwan
[3] H Lee Moffitt Canc Ctr & Res Inst, Dept Radiat Oncol, Tampa, FL USA
[4] Natl Yang Ming Univ, Dept Biomed Imaging & Radiol Sci, Taipei, Taiwan
关键词
Attenuation correction; Cine CT; Deformable image registration; PET; OPTICAL-FLOW; IMAGES;
D O I
10.1016/j.nima.2009.11.001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Because of the advantages in the use of high photon flux and thus the short scan times of CT imaging, the traditional Ge-68 scans for positron emission tomography (PET) image attenuation correction have been replaced by CT scans in the modern PET/CT technology. The combination of fast CT scan and slow PET scan often causes image misalignment between the PET and CT images due to respiration motion. Use of the average CT derived from cine CT images is reported to reduce such misalignment. However, the radiation dose to patients is higher with cine CT scans. This study introduces a method that uses breath-hold CT images and their interpolations to generate the average CT for PET image attenuation correction. Breath-hold CT sets are taken at end-inspiration and end-expiration. Deformable image registration is applied to generate a voxel-to-voxel motion matrix between the two CT sets. The motion is equally divided into 5 steps from inspiration to expiration and 5 steps from expiration to inspiration, generating a total of 8 phases of interpolated CT sets. An average CT image is generated from all the 10 phase CT images, including original inhale/exhale CT and 8 interpolated CT sets. Quantitative comparison shows that the reduction of image misalignment artifacts using the average CT from the interpolation technique for PET attenuation correction is at a similar level as that using cine average CT, while the dose to the patient from the CT scans is reduced significantly. The interpolated average CT method hence provides a low dose alternative to cine CT scans for PET attenuation correction. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:361 / 364
页数:4
相关论文
共 50 条
  • [1] Attenuation correction of PET cardiac data with low-dose average CT in PET/CT
    Pan, Tinsu
    Mawlawi, Osama
    Luo, Dershan
    Liu, Hui H.
    Chi, Pai-Chun M.
    Mar, Martha V.
    Gladish, Gregory
    Truong, Mylene
    Erasmus, Jeremy, Jr.
    Liao, Zhongxing
    Macapinlac, H. A.
    MEDICAL PHYSICS, 2006, 33 (10) : 3931 - 3938
  • [2] Interpolated average CT for cardiac PET/CT attenuation correction
    Greta S. P. Mok
    Cobie Y. T. Ho
    Bang-Hung Yang
    Tung-Hsin Wu
    Journal of Nuclear Cardiology, 2016, 23 : 1072 - 1079
  • [3] Interpolated average CT for cardiac PET/CT attenuation correction
    Mok, Greta S. P.
    Ho, Cobie Y. T.
    Yang, Bang-Hung
    Wu, Tung-Hsin
    JOURNAL OF NUCLEAR CARDIOLOGY, 2016, 23 (05) : 1072 - 1079
  • [4] Low dose interpolated average CT for thoracic PET/CT attenuation correction using an active breathing controller
    Sun, Tao
    Wu, Tung-Hsin
    Wang, Shyh-Jen
    Yang, Bang-Hung
    Wu, Nien-Yun
    Mok, Greta S. P.
    MEDICAL PHYSICS, 2013, 40 (10)
  • [5] Low Dose Interpolated Average CT for PET/CT Attenuation Correction Using an Active Breathing Controller (ABC)
    Sun, Tao
    Wu, Tung-Hsin
    Wu, Nien-Yun
    Mok, Greta S. P.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2856 - 2858
  • [6] Interpolated Average CT for Attenuation Correction in PET - A Simulation Study
    Mok, Greta S. P.
    Sun, Tao
    Wu, Tung-Hsin
    Chang, Mu-Bai
    Huang, Tzung-Chi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4121 - 4125
  • [7] Attenuation correction of cardiac PET with endexpiratory CT and average CT
    Sander, K.
    Pan, T.
    Roby, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S699 - S699
  • [8] Ultra low-dose CT attenuation correction in PET SPM
    Wang, Shyh-Jen
    Yang, Bang-Hung
    Tsai, Chia-Jung
    Yang, Ching-Ching
    Lee, Jason J. S.
    Wu, Tung-Hsin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 397 - 400
  • [9] Attenuation correction of PET images with interpolated average CT for thoracic tumors
    Huang, Tzung-Chi
    Mok, Greta S. P.
    Wang, Shyh-Jen
    Wu, Tung-Hsin
    Zhang, Geoffrey
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2559 - 2567
  • [10] Interpolated average CT for PET attenuation correction in different lesion characteristics
    Ho, Cobie Y. T.
    Wu, Tung-Hsin
    Mok, Greta S. P.
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (03) : 297 - 306