Development of a simple and sensitive high-performance liquid chromatography method for determination of glucosamine in pharmaceutical formulations

被引:0
|
作者
Nemati, Mahboob [1 ]
Valizadeh, Hadi
Ansarin, Masood
Ghaderi, Farank
机构
[1] Tabriz Univ Med Sci, Fac Pharm, Dept Pharmacognosy & Food Sci, Tabriz, Iran
[2] Tabriz Univ Med Sci, Drug Appl Res Ctr, Food Sci & Nutraceut Lab, Tabriz, Iran
[3] Tabriz Univ Med Sci, Fac Pharm, Dept Pharmaceut, Tabriz, Iran
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A column high-performance liquid chromatography (HPLC) method was developed for the determination of glucosamine in dosage forms. Glucosamine was derivatized by addition of a solution containing orthophthaldialdehyde. The HPLC separation was achieved on a Spherimage 80 ODS2 column (250 x 4 mm id, 5 mu m particle size) using an isocratic mobile phase containing phosphate buffer-methanol (90 + 10, v/v, pH 6.50) and methanol-tetrahydrofuran (97 + 3, v/v) in proportions of 85 + 15 at a flow rate of 1 mL/min, followed by fluorescence detection. The method was validated for specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The detector response for glucosamine HCl was linear over the concentration range of 0.1-20 mu g/mL with a correlation coefficient of 0.9980. The accuracy was between 99.4 and 100.8%. The LOD and the LOQ were 0.009 and 0.027 mu g/mL, respectively. The method was applied to determination of glucosamine in solid dosage forms.
引用
收藏
页码:354 / 357
页数:4
相关论文
共 50 条