Analyzing method of surface structures by X-ray photoelectron spectroscopy (XPS)

被引:1
|
作者
Kosugi, R
Fujita, S
Takakuwa, Y
Tani, J
Miyamoto, N
Yamazaki, Y
机构
[1] TOHOKU UNIV,ELECT COMMUN RES INST,SENDAI,MIYAGI 98077,JAPAN
[2] TOHOKU UNIV,RES INST SCI MEASUREMENTS,SENDAI,MIYAGI 98077,JAPAN
[3] TOHOKU UNIV,INST FLUID SCI,SENDAI,MIYAGI 98077,JAPAN
关键词
X-ray photoelectron diffraction; gaas; crystal structure; computer simulation; single-scattering-cluster model; nanostructure; solid diffusion; lattice site;
D O I
10.4028/www.scientific.net/MSF.204-206.755
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The single-scattering-cluster model for the simulation of X-ray photoelectron diffraction (XPD) of a GaAs(100)-c(8x2) surface has been investigated to obtain good agreement with the experimental XPD pattern. In the simulation by the single-scattering cluster-model with a spherical wave (SSC-SW), the calculation of the polar-scan XPD pattern is appreciably influenced by the cluster size as well as by the cluster shape and the agreement between the calculated and measured XPD patterns is not so good even for the very large cluster including 10(5) scatterer atoms. To overcome such influence and disagreement, it is important that the spatial distribution of the scatterer atoms is determined in terms of the scattering intensity of each scatterer atom: the only scatterer atoms with the scattering intensity above a specific critical vale epsilon should be taken into the simulation and all smaller scattering intensities than epsilon are cut down. The smaller critical value corresponds to the calculation with the scatterer atoms located at a deeper and wider position in the bulk. By choosing the critical value appropriately, the simulation obtained by the SSC-SW resembles well the measured Ga3d and As3d XPD patterns. The SSC model with a plane wave is also examined and compared with the SSC-SW model.
引用
收藏
页码:755 / 760
页数:6
相关论文
共 50 条
  • [21] XPS insights: Sample degradation in X-ray photoelectron spectroscopy
    Morgan, David J.
    SURFACE AND INTERFACE ANALYSIS, 2023, 55 (05) : 331 - 335
  • [22] X-RAY PHOTOELECTRON-SPECTROSCOPY (XPS) OF DENTIN SURFACES
    WILLIAMS, RL
    WILLIAMS, DF
    JOURNAL OF DENTAL RESEARCH, 1988, 67 (04) : 673 - 673
  • [23] Surface sensitivity of X-ray photoelectron spectroscopy
    Powell, C. J.
    Jablonski, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 601 (1-2): : 54 - 65
  • [24] Study of (0001) Ti surface by X-ray photoelectron spectroscopy method
    Frikkel, DP
    Kuznetsov, MV
    Shalayeva, YV
    FIZIKA METALLOV I METALLOVEDENIE, 1995, 80 (03): : 86 - 95
  • [25] Detection of Free Base Surface Enrichment of a Pharmaceutical Salt by X-ray Photoelectron Spectroscopy (XPS)
    Stevens, Joanna S.
    Byard, Stephen J.
    Zlotnikov, Evgeny
    Schroeder, Sven L. M.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 100 (03) : 942 - 948
  • [26] PLASMA INDUCED SURFACE MODIFICATION OF GAAS - AN X-RAY PHOTOELECTRON-SPECTROSCOPY (XPS) CHARACTERIZATION
    SAHA, NC
    TAM, G
    LEGGE, RN
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (08) : C364 - C364
  • [27] X-Ray Photoelectron Spectroscopy (XPS) used as a structural and chemical surface probe on aluminosilicate minerals
    Biino, GG
    Groning, P
    EUROPEAN JOURNAL OF MINERALOGY, 1998, 10 (03) : 423 - 437
  • [28] XPS (X-RAY PHOTOELECTRON-SPECTROSCOPY) IN STUDY OF MINERAL MATERIALS
    DILLARD, JG
    KOPPELMAN, MH
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1975, 56 (12): : 1004 - 1004
  • [29] X-ray photoelectron spectroscopy for resistance-capacitance measurements of surface structures
    Ertas, G
    Demirok, UK
    Atalar, A
    Suzer, S
    APPLIED PHYSICS LETTERS, 2005, 86 (18) : 1 - 3
  • [30] X-ray photoelectron spectroscopy (XPS) of carbon nitride (CN) films
    Mo, SB
    Liu, Y
    Yang, YZ
    Cheng, YH
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 1999, 19 (05) : 734 - 737