The Effect of Deck Width Addition Toward Stability of Cable Stayed Bridge: Case Study of Siak Sri Indrapura Bridge, Riau

被引:0
|
作者
Supriyadi, Bambang [1 ]
Siswosukarto, Suprapto [1 ]
Masagala, Algazt A. [2 ]
Hadjoh, Imanuel Elvis S. [3 ]
机构
[1] Univ Gadjah Mada, Civil Engn & Environm Dept, Yogyakarta, Indonesia
[2] Technol Univ Yogyakarta, Yogyakarta, Indonesia
[3] Univ Gadjah Mada, Dept Civil & Environm Engn, Yogyakarta, Indonesia
来源
INTERNATIONAL SYMPOSIUM ON CIVIL AND ENVIRONMENTAL ENGINEERING 2016 (ISCEE 2016) | 2017年 / 103卷
关键词
D O I
10.1051/matecconf/201710309010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An aeroelastic interaction always take places in long-span bridge, i.e. the dynamic relationship between wind forces (aerodynamic) and bridge structural motion (dynamics). Wind forces may lead to serviceability and safety problems, and may even cause instability of the whole bridge structure due to the flexibility nature of long span bridge structures. The slimer girder plate will make the structure more unstable as can be seen from the occurrence of lateral deformation. This paper presents the results analysis of cable stayed bridge that has total span of 640 m, two planes configuration of harp-typed hanger cable, the A shape pylons span along 320 m (main span), and side span of 160m. Structural analysis was conducted to determine the optimum ratio between width and spans of cable stayed bridge. The bridge was modeled with various width of 7 to 22 m. Structural modelling was conducted using SAP2000 software to analyze the structural stability of cable stayed bridge under wind load at speed of 35 m/s. The influence of wind loads to the cable stayed bridge stability can be seen based on the bridge deck deformation at the Y-axis (U-2), in which for the width of the bridge deck of 7 m, 8 m, 9 m and 10 m, the deformation of U2 are 0.26 m; 0.17 m; 0.12 m and 0.10 m, respectively. Meanwhile, for bridge's width of 11-22 m, the value of U2 axis deformation is relatively constant between 0.08 m to 0.07 m. This finding suggests that the ratio between width and length of bridge greatly affect the stability of the cable stayed bridge. Cable-stayed bridge, especially for concrete bridge, with two plain system having optimum ratio of width and length show no sign of an aerodynamic instability when fulfills the requirements of B >= L / 3.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Effect of cable-stayed bridge's relative height of deck on viscous damper's seismic reduction behavior
    Zhang, Wen-Xue
    Huang, Jian
    Wang, Jing-Jing
    Zhendong yu Chongji/Journal of Vibration and Shock, 2015, 34 (16): : 43 - 47
  • [22] Theoretical and experimental study on shear lag effect of partially cable-stayed bridge
    Wu G.-F.
    Xu H.
    Journal of Zhejiang University-SCIENCE A, 2005, 6 (8): : 875 - 877
  • [23] Effect of wind barriers on the aeroelastic instabilities of a hinged-deck cross-section cable-stayed bridge
    Lopez-Nunez, Elena
    Ogueta-Gutierrez, Mikel
    Gomez-Ortega, Omar
    Manzanares-Bercial, Raul
    Roibas-Millan, Elena
    Franchini, Sebastian
    ENGINEERING STRUCTURES, 2023, 287
  • [24] Study on Orthotropic Deck Plate Fatigue Test Model Scheme of Box Girder of Railway Cable-Stayed Bridge
    Han, Bing
    Pu, Qianhui
    Shi, Zhou
    Gao, Liqiang
    Zhou, Yang
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 1199 - 1205
  • [25] Study on Girder Erection Schemes for Long Cable-stayed Bridge with Broad Width Based on Buffeting Analysis
    Li, Xin
    You, Xinpeng
    2015 INTERNATIONAL CONFERENCE ON CIVIL ENGINEERING AND ROCK ENGINEERING, ICCERE 2015, 2015, : 340 - 346
  • [26] Nothing-on-Road Axle Detection Strategies in Bridge-Weigh-in-Motion for a Cable-Stayed Bridge: Case Study
    Kalhori, Hamed
    Alamdari, Mehrisadat Makki
    Zhu, Xinqun
    Samali, Bijan
    JOURNAL OF BRIDGE ENGINEERING, 2018, 23 (08)
  • [27] Effect of lateral brace on the stability of cable-stayed concrete filled steel tube arch bridge
    College of Civil Engineering, Hunan Univ, Changsha 410082, China
    不详
    Hunan Daxue Xuebao, 2006, 6 (6-10):
  • [28] Experimental Study of Aerodynamic Disturbance Effect of Existing Bridge on Main Girder of Under-Construction Cable-Stayed Bridge
    Wang C.-C.
    Ding D.-H.
    Zhu Y.
    Bridge Construction, 2023, 53 : 25 - 30
  • [29] Non-contact structural health monitoring of a cable-stayed bridge: case study
    Alamdari, Mehrisadat Makki
    Ge, Linlin
    Kildashti, Kamyar
    Zhou, Yincai
    Harvey, Bruce
    Du, Zheyuan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2019, 15 (08) : 1119 - 1136
  • [30] GPS for structural health monitoring - case study on the Basarab overpass cable-stayed bridge
    Lepadatu, Alexandru
    Tiberius, Christian
    JOURNAL OF APPLIED GEODESY, 2014, 8 (01) : 65 - 85