Glassy carbon electrode modified with poly(methyl orange) as an electrochemical platform for the determination of 4-nitrophenol at nanomolar levels

被引:41
|
作者
Giribabu, Krishnan [1 ,2 ]
Haldorai, Yuvaraj [3 ]
Rethinasabapathy, Muruganantham [2 ]
Jang, Sung -Chan [2 ,4 ]
Suresh, Ranganathan [1 ]
Cho, Wan-Seob [5 ]
Han, Young-Kyu [3 ]
Roh, Changhyun [4 ]
Huh, Yun Suk [2 ]
Narayanan, Vengidusamy [1 ]
机构
[1] Univ Madras, Dept Inorgan Chem, Guindy Maraimalai Campus, Chennai 600025, Tamil Nadu, India
[2] Inha Univ, Dept Biol Engn, Biohybrid Syst Res Ctr, WCSL Integrated Human Airway On A Chip, 100 Inha Ro, Incheon 22212, South Korea
[3] Dongguk Univ Seoul, Dept Energy & Mat Engn, 30,Pildong Ro 1 Gil, Seoul 04620, South Korea
[4] KAERI, ARTI, Biotechnol Res Div, 29 Geumgu Gil, Jeongeup Si 56212, Jeonbuk, South Korea
[5] Dong A Univ, Dept Med Biotechnol, Coll Hlth Sci, Toxicol Lab, 37,Nakdong Daero 550 Beon Gil, Busan 49315, South Korea
基金
新加坡国家研究基金会;
关键词
4-Nitrophenol; Poly(methyl orange); Electrochemical determination; Differential pulse voltammetry; RIVER WATER SAMPLES; VOLTAMMETRIC DETERMINATION; NITROPHENOL ISOMERS; PASTE ELECTRODE; LIQUID-CHROMATOGRAPHY; GRAPHENE OXIDE; NANOPARTICLES; METHYL; ACID;
D O I
10.1016/j.cap.2017.04.016
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, poly(methyl orange) (PMO) was synthesized by electrodeposition onto a glassy carbon electrode (GCE), and the resulting structure was examined for the determination of 4-nitrophenol (4-NP). Cyclic voltammetry revealed that the PMO-modified GCE (PMO/GCE) exhibited excellent electrocatalytic activity for the oxidation of 4-NP in a 0.5-M phosphate buffer solution. In contrast, the bare GCE showed no oxidation peak. Interestingly, PMO/GCE exhibited an oxidation peak at approximate 0.93 V, and the background current was higher than that of the bare GCE. Furthermore, the developed electrochemical sensor exhibited a linear relationship with the 4-NP concentration from 600 nM to 10 mu M, and the limit of detection was 170 nM (signal/noise = 3). The sensor demonstrated excellent selectivity, good stability, and reproducibility. It was applied to the determination of 4-NP in water samples by the standard addition method and gave recoveries of 99.2-100.9%. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:1114 / 1119
页数:6
相关论文
共 50 条
  • [21] Micro volume voltammetric determination of 4-nitrophenol in dimethyl sulfoxide at a glassy carbon electrode
    Gajdar, Julius
    Barek, Jiri
    Fojta, Miroslav
    Fischer, Jan
    MONATSHEFTE FUR CHEMIE, 2017, 148 (09): : 1639 - 1644
  • [22] Electrochemical Determination of 4-Nitrophenol Using a Single-Wall Carbon Nanotube Film-Coated Glassy Carbon Electrode
    Chunhai Yang
    Microchimica Acta, 2004, 148 : 87 - 92
  • [23] Electrochemical determination of 4-nitrophenol using a single-wall carbon nanotube film-coated glassy carbon electrode
    Yang, CH
    MICROCHIMICA ACTA, 2004, 148 (1-2) : 87 - 92
  • [24] Electrochemical detection of 4-nitrophenol based on a glassy carbon electrode modified with a reduced graphene oxide/Au nanoparticle composite
    Tang, Yanhong
    Huang, Run
    Liu, Chengbin
    Yang, Shanli
    Lu, Zhenzhen
    Luo, Shenglian
    ANALYTICAL METHODS, 2013, 5 (20) : 5508 - 5514
  • [25] Simultaneous electrochemical determination of nitrophenol isomers with the polyfurfural film modified glassy carbon electrode
    Wei, Tianyan
    Huang, Xinjian
    Zeng, Qiang
    Wang, Lishi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 743 : 105 - 111
  • [26] Determination of 4-nitrophenol using MoO3 loaded glassy carbon electrode via electrochemical sensing approach
    Kamble, Bhagyashri B.
    Garadkar, Kalyanrao M.
    Sharma, Kirankumar K.
    Kamble, Pravin
    Tayade, Shivaji N.
    Ajalkar, Balu D.
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2021, 11 (03): : 143 - 159
  • [27] Electrochemical synthesis of nickel–cobalt oxide nanoparticles on the glassy carbon electrode and its application for the voltammetric determination of 4-nitrophenol
    Karim Asadpour-Zeynali
    Elnaz Delnavaz
    Journal of the Iranian Chemical Society, 2017, 14 : 2229 - 2238
  • [28] Voltammetric determination of 4-nitrophenol using a glassy carbon electrode modified with a gold-ZnO-SiO2 nanostructure
    Arash Jalili Ghazizadeh
    Abbas Afkhami
    Hasan Bagheri
    Microchimica Acta, 2018, 185
  • [29] Voltammetric determination of 4-nitrophenol using a glassy carbon electrode modified with a gold-ZnO-SiO2 nanostructure
    Ghazizadeh, Arash Jalili
    Afkhami, Abbas
    Bagheri, Hasan
    MICROCHIMICA ACTA, 2018, 185 (06)
  • [30] Electrochemical determination of 4-nitrophenol using functionalized graphene oxide/functionalized multi-walled carbon nanotubes hybrid material modified glassy carbon electrode
    Saeed, Pasar Nizar
    Guler, Muhammet
    CHEMICAL PHYSICS, 2025, 588