An exact reconstruction algorithm for triple-source helical cone-beam CT

被引:0
|
作者
Zhao, Jun [1 ]
Jiang, Ming
Zhuang, Tiange
Wang, Ge
机构
[1] Shanghai Jiao Tong Univ, Dept Biomed Engn, Shanghai 200030, Peoples R China
[2] Peking Univ, Sch Math Sci, LMAM, Beijing 100871, Peoples R China
[3] Univ Iowa, Dept Radiol, Iowa City, IA 52242 USA
关键词
computed tomography (CT); cone-beam; triple-sources; helical scanning; filtered-backprojection (FBP); backprojected-filtration (BPF);
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
For dynamic CT reconstruction, we have conceptualized a triple-source helical cone-beam scanning mode, and formulated a backprojected-filtration (BPF) algorithm for exact image reconstruction. The algorithm uses data from the three inter-helix Mares related to the inter-helix PI-lines and the minimum detection windows defined for the triple-source configuration. The proof of the formula is based on Tuy's inversion formula and the geometric relations of inter-helix PI-lines. Simulation results demonstrate the validity of the reconstruction algorithm. The BPF algorithm is also extended for the (2N + 1)-source helical cone-beam CT.
引用
收藏
页码:191 / 206
页数:16
相关论文
共 50 条
  • [21] An exact reconstruction algorithm in variable pitch helical cone-beam CT when PI-line exists
    Li, Liang
    Chen, Zhiqiang
    Zhang, Li
    Kang, Kejun
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 109 - 118
  • [22] Generalized quasi-exact algorithms for image reconstruction in helical cone-beam CT
    Zou, Y
    Sidky, EY
    Pan, XC
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 696 - 702
  • [23] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [24] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [25] Exact helical reconstruction using native cone-beam geometries
    Noo, F
    Pack, J
    Heuscher, D
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (23): : 3787 - 3818
  • [26] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 95 - 107
  • [27] Exact radon rebinning algorithm for the long object problem in helical cone-beam CT
    Schaller, S
    Noo, F
    Sauer, F
    Tam, KC
    Lauritsch, G
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 361 - 375
  • [28] Minimum detection window and inter-helix PI-Line with triple-source helical cone-beam scanning
    Zhao, J
    Jiang, M
    Zhuang, TG
    Wang, G
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 599 - 610
  • [29] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China
    不详
    不详
    SPIE, 1600, 599-610 (2004):
  • [30] Exact FBP reconstruction for a cone-beam CT scanner with independent rotations of the source and the detector
    Rit, S.
    Clackdoyle, R.
    Keuschnigg, P.
    Steininger, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S198 - S199