New, faster, image-based scatter correction for 3D PET

被引:0
|
作者
Watson, CC [1 ]
机构
[1] CTI PET Syst Inc, Knoxville, TN 37932 USA
来源
1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3 | 1999年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report on a new numerical implementation of the single-scatter simulation scatter correction algorithm for 3D PET. Its primary advantage over the original implementation is that it is a much faster calculation, currently requiring less than 30 sec execution time per bed position for an adult thorax, thus making clinical whole-body scatter correction more practical. The new code runs on a single processor workstation CPU instead of a vector processor array, making it highly portable. It is modular and independent of any particular reconstruction code. The computed scatter contribution is now intrinsically scaled relative to the emission image and no longer requires normalization to the scatter tails in the sinogram when all activity is contained within the field of view, making it more robust against noise. The new algorithm has been verified against the original code on both phantom and human thorax studies. Initial results indicate that scatter correction may be accurately performed following, instead of prior to, either 3D reprojection or Fourier rebinning. Some evidence is presented that the single-scatter operator, when applied to an uncorrected emission image provides reasonable compensation for multiple scatter.
引用
收藏
页码:1637 / 1641
页数:3
相关论文
共 50 条
  • [31] 3D IMAGE-BASED MODELING ON METEORITICS
    Zucolotto, M. E.
    Grillo, O. N.
    METEORITICS & PLANETARY SCIENCE, 2009, 44 : A228 - A228
  • [32] Image-based refocusing by 3D filtering
    Kubota, Akira
    Kodama, Kazuya
    Hatori, Yoshinori
    ADVANCES IN IMAGE AND VIDEO TECHNOLOGY, PROCEEDINGS, 2007, 4872 : 385 - +
  • [33] 3D implementation of Scatter Estimation in 3D PET
    Iatrou, M.
    Manjeshwar, R. M.
    Ross, S. G.
    Thielemans, K.
    Stearns, C. W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2142 - 2145
  • [34] CHARACTERIZATION AND CORRECTION FOR SCATTER IN 3D PET USING REBINNED PLANE INTEGRALS
    WU, CW
    ORDONEZ, CE
    CHEN, CT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) : 2758 - 2764
  • [35] Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction
    Holdsworth, CH
    Levin, CS
    Farquhar, TH
    Dahlbom, M
    Hoffman, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 74 - 81
  • [36] Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation for 3D PET
    Ye, Jinghan
    Song, Xiyun
    Hu, Zhiqiang
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [37] Comparative evaluation of scatter correction in 3D PET using different scatter-level approximations
    Irene Polycarpou
    Kris Thielemans
    Ravindra Manjeshwar
    Pablo Aguiar
    Paul K. Marsden
    Charalampos Tsoumpas
    Annals of Nuclear Medicine, 2011, 25 : 643 - 649
  • [38] Comparative evaluation of scatter correction in 3D PET using different scatter-level approximations
    Polycarpou, Irene
    Thielemans, Kris
    Manjeshwar, Ravindra
    Aguiar, Pablo
    Marsden, Paul K.
    Tsoumpas, Charalampos
    ANNALS OF NUCLEAR MEDICINE, 2011, 25 (09) : 643 - 649
  • [39] Image-Based 3D Shape Generation Used for 3D Printing
    Li, Zemin
    Zhang, Lin
    Sun, Yaqiang
    Ren, Lei
    Laili, Yuanjun
    METHODS AND APPLICATIONS FOR MODELING AND SIMULATION OF COMPLEX SYSTEMS, 2018, 946 : 539 - 551
  • [40] New Tools for Image-Based Mesh Generation of 3D Imaging Data
    Young, P. G.
    Raymont, D.
    Xuan, V. Bui
    Cotton, R. T.
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 470 - +