Predictors of lead break during transvenous lead extraction

被引:15
|
作者
Morita, Junji [1 ]
Yamaji, Kyohei [1 ]
Nagashima, Michio [1 ]
Kondo, Yusuke [2 ]
Sadohara, Yohei [1 ]
Hirokami, Jun [1 ]
Kuji, Rei [1 ]
Korai, Kengo [1 ]
Fukunaga, Masato [1 ]
Hiroshima, Kenichi [1 ]
Ando, Kenji [1 ]
Goya, Masahiko [3 ]
机构
[1] Kokura Mem Hosp, Dept Cardiol, Kitakyushu, Fukuoka, Japan
[2] Chiba Univ, Grad Sch Med, Dept Cardiovasc Med, Chiba, Japan
[3] Tokyo Med & Dent Univ, Dept Cardiovasc Med, Tokyo, Japan
关键词
coradial lead; lead break; pacemaker lead; passive lead; transvenous lead extraction;
D O I
10.1002/joa3.12524
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The incidence, predictors, and clinical impact of lead break during transvenous lead extraction (TLE) were previously unknown. Methods We included consecutive patients who underwent TLE between September 2013 and July 2019 at our institute. Lead break during removal was defined as lead stretching and becoming misshapen, as assessed by fluoroscopy. Results A total of 246 patients underwent TLE for 501 leads. At a patient level, complete success was achieved in 226 patients (91.9%). At a lead level, 481 leads (96.0%) were completely removed and 101 leads (20.1%) were broken during the procedure. Of 392 identified pacemaker leads, 71 (18.3%) were broken during the TLE procedure. A multivariable analysis confirmed high lead age (odds ratio [OR] 1.12, 95% confidence interval (CI) 1.07-1.17; P < .001), passive leads (OR 2.29 95% CI 1.09-4.80; P = .028), coradial leads (OR 3.45 95% CI 1.72-6.92; P < .001), and insulators made of nonpolyurethane (OR 2.38 95% CI 1.03-5.26; P = .04) as predictors of lead break. Broken leads needed longer procedure times and were associated with a higher rate of cardiac tamponade. Conclusions Lead age, coradial bipolar leads, passive leads, and leads without polyurethane insulation were predictors of lead break and could increase the difficulty of lead extraction.
引用
收藏
页码:645 / 652
页数:8
相关论文
共 50 条
  • [31] Transvenous lead extraction: lead age threshold to predict the success of the procedure
    Santoro, M. Giannotti
    Segreti, L.
    Fiorentini, F.
    Bernini, G.
    Barletta, V.
    Della Tommasina, V.
    Cellamaro, T.
    Soldati, E.
    Di Cori, A.
    Zucchelli, G.
    De Lucia, R.
    Viani, S.
    Paperini, L.
    Pedrinelli, R.
    Bongiorni, M. G.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1909 - 1909
  • [32] Transvenous extraction of His bundle pacing lead: New challenge in the field of lead extraction
    Boczar, Krzysztof
    Zabek, Andrzej
    Debski, Maciej
    Gajek, Jacek
    Elakowski, Jacek L.
    Malecka, Barbara
    CARDIOLOGY JOURNAL, 2019, 26 (06) : 805 - 805
  • [33] Transvenous lead extraction during uninterrupted warfarin therapy: Feasibility and outcomes
    Zheng, Qi
    Maytin, Melanie
    John, Roy M.
    Killu, Ammar M.
    Epstein, Laurence M.
    HEART RHYTHM, 2018, 15 (12) : 1777 - 1781
  • [34] Benefits of routine prophylactic femoral access during transvenous lead extraction
    Chung, Da-Un
    Mueller, Lisa
    Ubben, Timm
    Yildirim, Yalin
    Petersen, Johannes
    Sinning, Christoph
    Castro, Liesa
    Demal, Till Joscha
    Kaiser, Lukas
    Gosau, Nils
    Reichenspurner, Hermann
    Willems, Stephan
    Pecha, Simon
    Hakmi, Samer
    HEART RHYTHM, 2021, 18 (06) : 970 - 976
  • [35] Clinical utility of intraprocedural transesophageal echocardiography during transvenous lead extraction
    Endo, Yuka
    O'Mara, John E.
    Weiner, Stanislav
    Han, Jennifer
    Goldberger, Mark H.
    Gordon, Garet M.
    Nanna, Michele
    Ferrick, Kevin J.
    Gross, Jay N.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (07) : 861 - 867
  • [36] Classification and Surgical Repair of Injuries Sustained During Transvenous Lead Extraction
    Bashir, Jamil
    Fedoruk, Lynn M.
    Ofiesh, John
    Karim, Shahzad S.
    Tyers, G. Frank O.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (09):
  • [37] Echocardiography reveals lost of silicone tubes during transvenous lead extraction
    Tomaszewski, A.
    Kutarski, A.
    Tomaszewski, M.
    Brzozowski, W.
    EUROPEAN HEART JOURNAL, 2012, 33 : 566 - 567
  • [38] Hybrid transvenous lead extraction during cardiac surgery for valvular endocarditis
    Yildirim, Yalin
    Petersen, Johannes
    Toennis, Tobias
    Reichenspurner, Hermann
    Pecha, Simon
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2101 - 2106
  • [39] Major predictors of fibrous adherences in transvenous implantable cardioverter-defibrillator lead extraction
    Segreti, Luca
    Di Cod, Andrea
    Soldati, Ezio
    Zucchelli, Giulio
    Viani, Stefano
    Paperini, Luca
    De Lucia, Raffaele
    Coluccia, Giovanni
    Valsecchi, Sergio
    Bongiorni, Maria Grazia
    HEART RHYTHM, 2014, 11 (12) : 2196 - 2201
  • [40] Predictors and outcomes of patients requiring repeat transvenous lead extraction of pacemaker and defibrillator leads
    Claridge, Simon
    Johnson, Jonathan
    Sadnan, Gazi
    Behar, Jonathan M.
    Porter, Bradley
    Sieniewicz, Benjamin
    Jackson, Tom
    Webb, Jessica
    Gould, Justin
    Sohal, Manav
    Hamid, Shoaib
    Patel, Nik
    Gill, Jaswinder
    Rinaldi, Christopher A.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (02): : 155 - 160