X-ray pinhole camera images and electron beam modeling of the Xoft Axxent® source

被引:0
|
作者
Axelrod, S.
Rusch, T.
Zheng, Z.
Wilfley, B.
Case, T.
机构
[1] Xoft Inc, Fremont, CA USA
[2] Triple Ring Technol Inc, Palo Alto, CA USA
关键词
D O I
10.1118/1.2761767
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To understand the propagation of electrons through the acceleration gradient of the Xoft micro‐miniature x‐ray source via electrostatic modeling of the fields and x‐ray pinhole camera imaging. Materials and Methods: 1) A 3D model of the source was built using OmniTrak3, and electron trajectories were traced from the hot cathode to the x‐ray producing anode. A finite element model of the filament temperature profile was input to a Richardson‐Dushman thermionic emission/extraction model to determine the electron emission density distribution. Assumptions made were that the field was graded linearly along the length, and that electrical connection between conductive and resistive components was ideal. 2) A ShadoCam4 x‐ray sensitive camera was used to acquire images of sources through a 30 μm pinhole mounted 15 mm from the source. The camera was 105 mm from the pinhole, providing a magnification of 7×. The camera was read out through a USB computer interface. Images were typically acquired over ten second integration times. Results: The actual images showed distinct patterns that were identifiable with model predictions. Structures associated with particular emission locations and launch angles on the filament were clearly observed. Conversely, patterns in the images were explainable in terms of parameters such as the absolute location of the filament. Image patterns which were relatively similar to the nominal had no correlation with measured spatial distribution patterns of the sources, but where there were notable variations in the image patterns it was possible to infer correlations with polar and/or azimuthal measurements. Conclusions: Electron trajectories within the accelerating structure were explored through pinhole imaging and computer modeling, and sensitivities to mechanical tolerances were established that were valuable in setting manufacturing tolerances. This study was funded by Xoft, Inc. 3 Field Precision LLC, Albuquerque, NM. 4 Rad‐icon Imaging Corp, Santa Clara, CA. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2652 / 2652
页数:1
相关论文
共 50 条
  • [1] Monte Carlo modeling of the Xoft AXXENT™ x-ray source
    Rusch, T
    Bohm, T
    Rivard, M
    MEDICAL PHYSICS, 2005, 32 (06) : 2017 - 2018
  • [2] Monte Carlo modelling of the Xoft AXXENT x-ray source
    Taylor, R. E. P.
    Yegin, G.
    Rogers, D. W. O.
    MEDICAL PHYSICS, 2006, 33 (06) : 2205 - 2205
  • [3] Stability of the xoft Axxent® X-ray source during simulated APBI
    Burnside, R.
    La, Q.
    Mihaylov, J.
    Rusch, T.
    Axelrod, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2490 - 2490
  • [4] Stability of the Xoft Axxent X-Ray Source during Simulated IORT Procedures
    Hughes, D.
    Rusch, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [5] Calculated and measured radiation dose for the low energy xoft axxent eBT X-ray source
    Sümeyra Can
    Özge Atilla
    Didem Karaçetin
    BMC Research Notes, 16
  • [6] Volumetric analysis of dose delivered by Xoft Axxent X-ray sources
    Axelrod, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2150 - 2150
  • [7] Calculated and measured radiation dose for the low energy xoft axxent eBT X-ray source
    Can, Suemeyra
    Atilla, Oezge
    Karacetin, Didem
    BMC RESEARCH NOTES, 2023, 16 (01)
  • [8] Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent X-Ray Source: An electronic brachytherapy source
    Rivard, Mark J.
    Davis, Stephen D.
    DeWerd, Larry A.
    Rusch, Thomas W.
    Axelrod, Steve
    MEDICAL PHYSICS, 2006, 33 (11) : 4020 - 4032
  • [9] A High Precision, High Throughput Fixture for Routine Spatial Characterization of the Xoft Axxent™ Miniature X-Ray Source
    Kelley, L.
    Axelrod, S.
    Powell, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Determination of the ReA Electron Beam Ion Trap electron beam radius and current density with an X-ray pinhole camera
    Baumann, Thomas M.
    Lapierre, Alain
    Kittimanapun, Kritsada
    Schwarz, Stefan
    Leitner, Daniela
    Bollen, Georg
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (07):