Development and evaluation of reaction gas chromatograph as a calibration method using an index compound

被引:1
|
作者
Watanabe, T [1 ]
Kato, K [1 ]
Matsumoto, N [1 ]
Maeda, T [1 ]
机构
[1] AIST Tsukuba Cent 3, Organ Analyt Chem Div, NMIJ, Tsukuba, Ibaraki 3058563, Japan
关键词
micro reactor; reaction gas chromatography; GC/MS; hydrogenation; hydrodechlorination; calibration method; index compound;
D O I
10.2116/bunsekikagaku.52.265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to realize a technique that serves as a calibration method using an index compound, reaction gas chromatography was examined. An index compound represents a group which includes many compounds; compounds in this group can be calibrated using the index compound. The gas chromatograph/micro reactor/mass spectrometer (GC/MR/MS) consists of a capillary gas chromatograph/mass spectrometer and a micro reactor. By using the MR, alkenes and alkynes were transformed to alkanes having the same carbon skeleton. Ethylene in a cylinder was determined using ethane as an index compound. The results showed good agreement with a reference value. The hydrodechlorination of chlorobenzenes was examined. Chlorobenzene in a solution was determined by using benzene as an index compound. The experimental results and reference concentration showed a good agreement. The efficacy of this technique was demonstrated with these results.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 50 条
  • [21] Early detection of milk spoilage via volatile organic compound analysis using multidimensional gas chromatograph/mass spectrometry
    Rochford, Kevin
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [22] Surface cleaning and nitridation of compound semiconductors using gas-decomposition reaction in Cat-CVD method
    Izumi, A
    Masuda, A
    Matsumura, H
    THIN SOLID FILMS, 1999, 343 : 528 - 531
  • [23] Measurement method for finding gas adsorption equilibrium isotherms by employing a gas chromatograph and using its integrator in a new way
    Eriksson, T
    Sylwan, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (04): : 1 - 8
  • [24] IMPROVED PRECISION GAS-CHROMATOGRAPHIC METHOD FOR RETENTION INDEX MONITORING WITH A CALIBRATION DETECTOR
    ENQVIST, J
    SUNILA, P
    LAKKISTO, UM
    JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV): : 667 - 673
  • [25] The Evaluation Index System and Method of Sustainable Uranium Development
    Gong, Chenggang
    Liu, Songlin
    WKDD: 2009 SECOND INTERNATIONAL WORKSHOP ON KNOWLEDGE DISCOVERY AND DATA MINING, PROCEEDINGS, 2009, : 668 - 671
  • [26] Evaluation index system and evaluation method of sustainable development in mining areas
    Tang, Wanjin
    Gao, Lin
    Li, Xiangyi
    Xitong Gongcheng Lilun yu Shijian/System Engineering Theory and Practice, 1999, 19 (12): : 114 - 119
  • [27] Evaluation Index System and Evaluation Method of Sustainable Development of Regional Economy
    Chen Xuezhong
    Yang Huan
    PROCEEDINGS OF 2008 CONFERENCE ON REGIONAL ECONOMY AND SUSTAINABLE DEVELOPMENT, 2008, : 21 - 24
  • [28] COMPREHENSIVE METHOD FOR THE DETERMINATION OF ANTIEPILEPTIC DRUGS USING A NOVEL EXTRACTION TECHNIQUE AND A FULLY AUTOMATED GAS CHROMATOGRAPH
    RAMBECK, B
    MEIJER, JWA
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1979, 29-1 (01): : 99 - 103
  • [29] A segmental calibration method for a miniature serial-link coordinate measuring machine using a compound calibration artefact
    Zhou, Awei
    Guo, Junjie
    Shao, Wei
    Li, Beizhan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (06)
  • [30] DEVELOPMENT OF A GAS-CHROMATOGRAPH FOR TRACE-LEVEL MEASUREMENT OF PEROXYACETYL NITRATE USING CHEMICAL AMPLIFICATION
    BLANCHARD, P
    SHEPSON, PB
    SCHIFF, HI
    DRUMMOND, JW
    ANALYTICAL CHEMISTRY, 1993, 65 (18) : 2472 - 2477