Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer

被引:72
|
作者
Zhu, JH [1 ]
Zhu, ZQ
Lai, ZS
Wang, R
Guo, XM
Wu, XQ
Zhang, GX
Zhang, ZR
Zhang, ZR
Wang, YT
Chen, ZY
机构
[1] E China Normal Univ, IT Coll, Shanghai 200062, Peoples R China
[2] Shanghai Teachers Univ, Shanghai 2000234, Peoples R China
[3] Shanghai Inst Med Control, Shanghai 200233, Peoples R China
[4] Fudan Univ, Dept Surg, Huashan Hosp, Shanghai 200040, Peoples R China
来源
SENSORS | 2002年 / 2卷 / 04期
关键词
Prussian Blue; electrocatalysis; chitosan; selective permeability; glucose sensor;
D O I
10.3390/s20400127
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV ( versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michanelis-Menten constant of the sensor is 21 mM. The response time is less than 60 seconds. No apparent change in the response to glucose was observed during one month. Foremost, the interference of ascorbic and uric acids can be avoided due to selective permeability of chitosan film and electrocatalysis of PB layer to H2O2. The sensor has been applied to detect glucose in human blood serum.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [21] An Amperometric Glucose Biosensor Composed of Prussian Blue, Nafion, and Glucose Oxidase Studied by Flow Injection Analysis
    Drew, Steven M.
    Belzer, Tristan
    JOURNAL OF CHEMICAL EDUCATION, 2023, 100 (02) : 760 - 766
  • [22] AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM
    KAKU, T
    KARAN, HI
    OKAMOTO, Y
    ANALYTICAL CHEMISTRY, 1994, 66 (08) : 1231 - 1235
  • [23] Glucose Sensor Based on Glucose Oxidase Immobilized by Zirconium Phosphate
    Sejin Park
    Taek Dong Chung
    Sun Kil Kang
    Ran-A Jeong
    Hankil Boo
    Hee Chan Kim
    Analytical Sciences, 2004, 20 : 1635 - 1638
  • [24] Glucose sensor based on glucose oxidase immobilized by zirconium phosphate
    Park, SJ
    Chung, TD
    Kang, SK
    Jeong, RA
    Boo, HK
    Kim, HC
    ANALYTICAL SCIENCES, 2004, 20 (12) : 1635 - 1638
  • [25] An Amperometric Glucose Biosensor Based on Titania Sol-gel/Prussian Blue Composite Film
    Ruping Liang
    Jingli Jiang
    Jianding Qiu
    Analytical Sciences, 2008, 24 : 1425 - 1430
  • [26] An Amperometric Glucose Biosensor Based on Titania Sol-gel/Prussian Blue Composite Film
    Liang, Ruping
    Jiang, Jingli
    Qiu, Jianding
    ANALYTICAL SCIENCES, 2008, 24 (11) : 1425 - 1430
  • [27] Prussian Blue Modified Amperometric Hg2+ Ion Biosensor Based on Glucose Oxidase Inhibition
    Virbickas, Povilas
    Ziziunaite, Gerda
    Ramanavicius, Arunas
    Valiuniene, Ausra
    ELECTROANALYSIS, 2023, 35 (04)
  • [28] Frequency response of the glucose sensor based on immobilized glucose oxidase membrane
    Gondo, S
    Kim, C
    Morishita, M
    Kawakami, M
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1996, 57-8 : 877 - 884
  • [29] Amperometric glucose biosensor based on direct assembly of Prussian blue film with ionic liquid-chitosan matrix assisted enzyme immobilization
    Zhang, Yannan
    Liu, Yu
    Chu, Zhenyu
    Shi, Lei
    Jin, Wanqin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 978 - 984
  • [30] Amperometric glucose determination by means of glucose oxidase immobilized on a cellulose acetate film: Dependence on the immobilization procedures
    Portaccio, Marianna
    Durante, Daniela
    Viggiano, Andrea
    Di Martino, Silvana
    De Luca, Paola
    Di Tuoro, Daniela
    Bencivenga, Umberto
    Rossi, Sergio
    Canciglia, Paolo
    De Luca, Bruno
    Mita, Datniano Gustavo