摘要
The use of aeration tank settling during high hydraulic loads on large wastewater treatment plants has previously been demonstrated as a reliable technique and proven valuable. The paper proposes a simplified deterministic model to predict the efficiency of the method. It is shown that a qualitatively correct model can be established. The simplicity of the model allows for on-line identification of the necessary parameters, so that no maintenance is needed to use of the on-line model for control. The practical implementation on three plants indicates that implementation of STAR with ATS control gives 50% increase of plant capacity for 3% extra cost.
引用
收藏
页码:179 / 184
页数:6
相关论文
共 50 条
  • [31] Adaptive modeling and classification of the secondary settling tank
    Yoo, CK
    Choi, SW
    Lee, IB
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (03) : 377 - 382
  • [32] Equilibrium control of settling tank and regenerator in FCCU
    Jiang, Yue
    Huagong Zidonghua Ji Yibiao/Control and Instruments in Chemical Industry, 2000, 27 (05): : 23 - 24
  • [33] Adaptive modeling and classification of the secondary settling tank
    Chang Kyoo Yoo
    Sang Wook Choi
    In-Beum Lee
    Korean Journal of Chemical Engineering, 2002, 19 : 377 - 382
  • [34] DESIGNING YOUR OWN OIL SETTLING TANK
    WEINDEL, HF
    PLANT ENGINEERING, 1979, 33 (08) : 265 - 267
  • [35] FLOW EQUALIZATION BY USE OF AERATION TANK VOLUME
    SPEECE, RE
    LAGREGA, M
    JOURNAL WATER POLLUTION CONTROL FEDERATION, 1976, 48 (11): : 2599 - 2608
  • [36] CFD for the optimization of ventilation mode of an aeration tank
    Wei, W.
    Lou, Ch
    Wei, J.
    Zhao, X.
    Chang, Y.
    DESALINATION AND WATER TREATMENT, 2020, 201 : 95 - 109
  • [37] Deep tank extended aeration of refinery wastes
    Rose, W.L.
    Gorringe, R.E.
    1600, (46):
  • [38] STRIPPING OF BENZENE AND TOLUENE IN BUBBLE AERATION TANK
    CHO, JS
    WAKAO, N
    CHEMICAL ENGINEERING COMMUNICATIONS, 1987, 56 (1-6) : 139 - 148
  • [39] Aeration tank lowers effluent BOD levels
    不详
    CHEMICAL PROCESSING, 2000, 63 (12): : 44 - 44
  • [40] AN INVESTIGATION OF RICE BRAN OIL TANK SETTLING
    BELAVADI, VK
    BHOWMICK, DN
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1988, 65 (02) : 241 - 245