Comparison of two amplification technologies for detection and quantitation of human immunodeficiency virus type 1 RNA in the female genital tract

被引:20
|
作者
Bremer, J [1 ]
Nowicki, M
Beckner, S
Brambilla, D
Cronin, M
Herman, S
Kovacs, A
Reichelderfer, P
机构
[1] Rush Med Coll, Chicago, IL 60612 USA
[2] Univ So Calif, Los Angeles, CA 90033 USA
[3] WESTAT Corp, Rockville, MD 20850 USA
[4] New England Res Inst, Watertown, MA 02472 USA
[5] Organon Tekn Corp, Durham, NC 27712 USA
[6] Roche Mol Syst Inc, Dept Infect Dis, Alameda, CA 94501 USA
[7] NICHHD, Bethesda, MD 20892 USA
关键词
D O I
10.1128/JCM.38.7.2665-2669.2000
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Human immunodeficiency virus type 1 (HIV-1) RNA levels in female genital tract and peripheral blood samples were compared using two commercial amplification technologies: the Roche AMPLICOR HIV-1 MONITOR test and either the Organon Teknika nucleic acid sequence-based amplification (NASBA-QT) assay or the NucliSens assay. Estimates of HIV-1 RNA copy number were derived from internal kit standards and analyzed unadjusted and adjusted to a common set of external standards. We found a discordance rate of approximately 18% between the two technologies for the detection of HIV-1 in either the genital tract or peripheral blood samples. Detection discordance was not consistent among specimens or among women. There were no significant differences In adjusted or unadjusted estimates of HIV-1 RNA copy number in the genital tract samples using the AMPLICOR HIV-1 MONITOR test and either the NASBA-QT assay or the NucliSens assay, In addition, the estimated HIV-1 RNA copy number in peripheral blood samples did not differ when tested with the NucliSens assay and the AMPLICOR HIV-1 MONITOR test using kit standards. However, there was a significant difference In estimated RNA copy number between the NASBA-QT assay and the AMPLICOR HIV-1 MONITOR test for internal kit standards, which, as we have previously shown, was eliminated after adjustment with the external standards. Our results suggest that the Roche and Organon Teknika assays are equivalent for quantifying HIV-1 RNA in female genital tract specimens, although variation in detection does exist.
引用
收藏
页码:2665 / 2669
页数:5
相关论文
共 50 条
  • [21] Detection of infectious human immunodeficiency virus type 1 in female genital secretions by a short-term culture method
    Cummins, JE
    Villanueva, JM
    Evans-Strickfaden, T
    Sesay, SM
    Abner, SR
    Bush, TJ
    Green, TA
    Lennox, JL
    Wright, T
    Folks, TM
    Hart, CE
    Dezzutti, CS
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (09) : 4081 - 4088
  • [22] Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma
    Erice, A
    Brambilla, D
    Bremer, J
    Jackson, JB
    Kokka, R
    Yen-Lieberman, B
    Coombs, RW
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (08) : 2837 - 2845
  • [23] Detection and quantitation of human immunodeficiency virus type-1 particles by confocal microscopy
    Bhattacharya, B
    Weiss, RA
    Davis, C
    Holmes, H
    Hockley, D
    Fassati, A
    JOURNAL OF VIROLOGICAL METHODS, 2004, 120 (01) : 13 - 21
  • [24] Comparative evaluation of three assays for the quantitation of human immunodeficiency virus type 1 RNA in plasma
    Coste, J
    Montes, B
    Reynes, J
    Peeters, M
    Segarra, C
    Vendrell, JP
    Delaporte, E
    Segondy, M
    JOURNAL OF MEDICAL VIROLOGY, 1996, 50 (04) : 293 - 302
  • [25] Quantitation of human immunodeficiency virus type 1 in breast milk
    Ghosh, MK
    Kuhn, L
    West, J
    Semrau, K
    Decker, D
    Thea, DM
    Aldrovandi, GM
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) : 2465 - 2470
  • [27] Variability of human immunodeficiency virus-1 in the female genital reservoir during genital reactivation of herpes simplex virus type 2
    LeGoff, J.
    Roques, P.
    Jenabian, M. -A.
    Charpentier, C.
    Brochier, C.
    Bouhlal, H.
    Gresenguet, G.
    Frost, E.
    Pepin, J.
    Mayaud, P.
    Belec, L.
    CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (09) : 873.e1 - 873.e9
  • [28] Human immunodeficiency virus (HIV) type-1 infection in the male genital tract: Implications for transmission
    Coombs, RW
    Reichelderfer, PS
    Landay, AL
    PROCEEDING OF 9TH INTERNATIONAL SYMPOSIUM ON SPERMATOLOGY, 2002, : 209 - 215
  • [29] Penetration of the nucleoside analogue abacavir into the genital tract of men infected with human immunodeficiency virus type 1
    van Praag, RME
    van Heeswijk, RPG
    Jurriaans, S
    Lange, JMA
    Hoetelmans, RMW
    Prins, JM
    CLINICAL INFECTIOUS DISEASES, 2001, 33 (08) : E91 - E92
  • [30] Repertoire of chemokine receptor expression in the female genital tract - Implications for human immunodeficiency virus transmission
    Patterson, BK
    Landay, A
    Andersson, J
    Brown, C
    Behbahani, H
    Jiyamapa, D
    Burki, Z
    Stanislawski, D
    Czerniewski, MA
    Garcia, P
    AMERICAN JOURNAL OF PATHOLOGY, 1998, 153 (02): : 481 - 490