Measurements of electron beam characteristics in the moderate-power 4-mm gyrotron

被引:0
|
作者
Kas'yanenko, D [1 ]
Louksha, O [1 ]
Piosczyk, B [1 ]
Sominski, G [1 ]
Thumm, M [1 ]
机构
[1] SPbSPU, St Petersburg 195251, Russia
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the 74.2 GHz moderate-power pulse gyrotron, influence of low-frequency parasitic oscillations in the electron beam tunnel on electron energy spread is determined. A method for suppressing parasitic oscillations by using non-uniform magnetic field in the compression region is studied. The characteristics of the electron beam in dependence of azimuthal inhomogeneity of electron emission have been investigated.
引用
收藏
页码:661 / 662
页数:2
相关论文
共 50 条
  • [41] Depletion of superjunction power MOSFETs visualized by electron beam induced current and voltage contrast measurements
    Kirnstoetter, Stefan
    Faccinelli, Martin
    Jelinek, Moriz
    Schustereder, Werner
    Laven, Johannes G.
    Schulze, Hans-Joachim
    Hadley, Peter
    PHYSICA STATUS SOLIDI C: CURRENT TOPICS IN SOLID STATE PHYSICS, VOL 11, NO 11-12, 2014, 11 (11-12): : 1707 - 1710
  • [42] CHARACTERISTICS OF PHOTOGRAPHIC-EMULSIONS IRRADIATING BY ELECTRON-BEAM .4.
    FUKAMI, A
    FUKUSHIM.K
    SETO, K
    HIROHATA, Y
    JOURNAL OF ELECTRON MICROSCOPY, 1972, 21 (03): : 254 - 254
  • [43] SENSITIVE 4 MM LECHER WIRE INTERFEROMETER FOR ELECTRON CONCENTRATION MEASUREMENTS IN LOW-DENSITY PLASMAS
    POLMAN, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (11): : 1631 - &
  • [44] Comparison of electron-beam-misalignment effect on starting current and output power in coaxial-cavity and cylindrical-cavity gyrotron oscillators
    Zhang, SC
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2000, 21 (04): : 547 - 551
  • [45] Comparison of Electron-Beam-Misalignment Effect on Starting Current and Output Power in Coaxial-Cavity and Cylindrical-Cavity Gyrotron Oscillators
    Shi-Chang Zhang
    International Journal of Infrared and Millimeter Waves, 2000, 21 : 547 - 551
  • [46] The Use of 4-mm Implants Splinted to 10-mm Implants for Replacement of Multiple Missing Teeth in the Posterior Maxilla Region with Expanded Maxillary Sinus. An Observational Cases Series: Patient Characteristics and Preliminary Results
    Gaspersic, Rok
    Dard, Michel
    Linder, Susy
    Oblak, Cedomir
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2021, 41 (02) : 261 - 268
  • [47] High-power up to 4 W characteristics of the capacitive microwave power sensor with grounded beam
    Yan, Hao
    Liao, Xiaoping
    ELECTRONICS LETTERS, 2015, 51 (22) : 1798 - 1799
  • [48] POTENTIAL MEASUREMENTS ON FLOATING-FIELD-LIMITING RINGS IN A POWER MOSFET BY AN ELECTRON-BEAM PROBE
    NAKAMAE, K
    KOMUKAI, S
    FUJIOKA, H
    SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 1995, 10 (03) : 249 - 254
  • [49] THRESHOLD POWER-DENSITY MEASUREMENTS FOR ELECTRON-BEAM SUSTAINED DISCHARGE EXCITATION OF XEF AND KRF
    FISHER, CH
    CENTER, RE
    APPLIED PHYSICS LETTERS, 1977, 31 (02) : 106 - 108
  • [50] Performance optimization for 150 kV inverter power supply and its electron beam source characteristics
    Xu H.
    Sang X.
    Zhang W.
    Qi B.
    Xu, Haiying (xhyxhy@126.com), 1600, Beijing University of Aeronautics and Astronautics (BUAA) (43): : 1550 - 1558