Studies on substation voltage and reactive power automatic regulating criteria

被引:0
|
作者
Li, Jiwen [1 ]
Liu, Xuelian [2 ]
Wang, Yubin [1 ]
Li, Hongmei [3 ]
机构
[1] Shandong Univ, Dept Elect Engn, Shandong 250061, Peoples R China
[2] Beijing Technol & Business Univ, Sch Informat Engn, Beijing 100037, Peoples R China
[3] Shandong Elect Power Corp, Shandong, Peoples R China
关键词
substation; voltage and reactive power automatic regulation; fuzzy;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper suggests a new criterion for substation voltage regulation and reactive power automatic regulation, which introduces voltage status into reactive power regulation criterion, making the reactive power regulation boundary a fuzzy one variable with voltage status. Being agreeable to human judgement, this criterion can improve compensation effects and effective in keeping a stable voltage and reducing the number of on-load tapping switch adjustments.
引用
收藏
页码:593 / +
页数:2
相关论文
共 50 条
  • [31] Operation characteristic of ultra-high voltage transmission line and reactive power compensation of substation
    State Key Laboratory of Power Transmission Equipment and System Security and New Technology, Chongqing University, Chongqing 400030, China
    不详
    Gaodianya Jishu, 2009, 7 (1533-1539):
  • [32] Study on hybrid automatic voltage control strategy of substation
    Wang Zhi-Tao
    He Guangyu
    Mei Sheng-Wei
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 1658 - +
  • [33] The Method and Structure of Switching on and off, and Regulating the Voltage of a Transformer Substation
    Klimash, V. S.
    Tabarov, B. D.
    2018 INTERNATIONAL SCIENTIFIC MULTI-CONFERENCE ON INDUSTRIAL ENGINEERING AND MODERN TECHNOLOGIES (FAREASTCON), 2018,
  • [34] Automatic Voltage and Reactive Power Regulator for Wind Farms participating to TSO Voltage Regulation.
    Chiandone, M.
    Campaner, R.
    Arcidiacono, V.
    Sulligoi, G.
    Milano, F.
    2015 IEEE EINDHOVEN POWERTECH, 2015,
  • [35] Control Configurations for Reactive Power Compensation at the Secondary Side of the Low Voltage Substation by Using Hybrid Transformer
    Radi, Mohammed
    Darwish, Mohamed
    Taylor, Gareth
    Pisica, Ioana
    ENERGIES, 2021, 14 (03)
  • [36] Application of Neuro-Fuzzy Dynamic Programming to Improve the Reactive Power and Voltage Profile of a Distribution Substation
    Haque, M. Tarafdar
    Najafi, S.
    PROCEEDINGS OF WORLD ACADEMY OF SCIENCE, ENGINEERING AND TECHNOLOGY, VOL 6, 2005, : 126 - 129
  • [37] Experience in the Implementation of an Automatic System for Stabilizing the Mode of a Power District in Terms of Voltage and Reactive Power
    Kostenko V.V.
    Gorozhankin P.A.
    Power Technology and Engineering, 2017, 51 (04) : 478 - 480
  • [38] AREA AUTOMATIC-CONTROL OF VOLTAGE AND REACTIVE POWER USING A MULTIVARIABLE APPROACH
    BJELIC, S
    JELIC, N
    ELECTRICAL TECHNOLOGY, 1995, (02): : 99 - 119
  • [39] Automatic Control System of Voltage and Reactive Power in the Dispatching Side and Its Application
    Tu, Dejun
    2014 IEEE WORKSHOP ON ELECTRONICS, COMPUTER AND APPLICATIONS, 2014, : 987 - 990
  • [40] Simulation of Substation Voltage and Reactive Control Based on Fuzzy Theory
    Zhang, Zhonghui
    Qian, Ming
    PROCEEDINGS OF 2010 3RD IEEE INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND INFORMATION TECHNOLOGY, VOL 9 (ICCSIT 2010), 2010, : 543 - 546