Hyperbranched Gold Plasmonic Blackbodies Enhanced Immunochromatographic Test Strip for the Sensitive Detection of Aflatoxin B1 in Maize Sample

被引:5
|
作者
Zhang, Zhen [1 ,2 ]
Wu, Yuhao [1 ,2 ]
Chen, Qi [3 ]
Huang, Xiaolin [1 ,2 ]
Xiong, Yonghua [1 ,2 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[2] Nanchang Univ, Sch Food Sci & Technol, Nanchang 330047, Jiangxi, Peoples R China
[3] Hainan Univ, Coll Food Sci & Engn, Haikou 570228, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
Hyperbranched gold plasmonic blackbodies; Immunochromatographic test strip; Aflatoxin B-1; Maize; LATERAL FLOW ASSAYS; PERFORMANCE; FOOD;
D O I
10.1007/s12161-021-02014-3
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this work, we synthesized a novel hyperbranched Au plasmonic blackbody (AuPB) and applied it as a signal amplification label in immunochromatographic test strip (ICTS) sensor for the sensitive detection of aflatoxin B-1 (AFB(1)) in maize. AuPB were characterized with high color signal intensity, superior colloidal stability, and excellent biocompatibility benefiting from the hyperbranched structure and the dense polydopamine layer on surface, which contributes to improving the sensitivity and robustness of competitive ICTS sensor. Under the optimized conditions, the half inhibition concentration and the detection limit of our AuPB-enhanced ICTS (AuPB-ICTS) sensor were 0.087 and 0.016 ng/mL, which are 3.9- and 5.4-fold lower than those of traditional ICTS sensor based on 35-nm gold nanospheres as signal reporters. The average recoveries for the intra- and inter-assay ranged from 92.5 to 119.5%, with the coefficient of variation of 3.29-10.28%. Moreover, the reliability and practicability of this method were validated by the well-established ultra-performance liquid chromatography method via simultaneously measuring fifteen naturally contaminated maize samples. In summary, the developed AuPB-ICTS sensor can serve as an alternative rapid diagnostic method to allow the sensitive and reliable screening of AFB(1) in maize.
引用
收藏
页码:2017 / 2025
页数:9
相关论文
共 50 条
  • [21] Immunochromatographic Assay for Ultrasensitive Detection of Aflatoxin B1 in Maize by Highly Luminescent Quantum Dot Beads
    Ren, Meiling
    Xu, Hengyi
    Huang, Xiaolin
    Kuang, Min
    Xiong, Yonghua
    Xu, Hong
    Xu, Yang
    Chen, Hongyu
    Wang, Andrew
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (16) : 14215 - 14222
  • [22] A dual-mode immunochromatographic sensor with photothermal and surface-enhanced Raman scattering for sensitive detection of aflatoxin B1
    Wang, Qian
    Ren, Yongjiao
    Li, Shijie
    Wang, Junping
    MICROCHEMICAL JOURNAL, 2024, 206
  • [23] Urchin-like gold nanoparticle-based immunochromatographic strip test for rapid detection of fumonisin B1 in grains
    Ren, Wenjie
    Huang, Zhibing
    Xu, Yang
    Li, Yanping
    Ji, Yanwei
    Su, Baowei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (24) : 7341 - 7348
  • [24] Urchin-like gold nanoparticle-based immunochromatographic strip test for rapid detection of fumonisin B1 in grains
    Wenjie Ren
    Zhibing Huang
    Yang Xu
    Yanping Li
    Yanwei Ji
    Baowei Su
    Analytical and Bioanalytical Chemistry, 2015, 407 : 7341 - 7348
  • [25] Application of green synthesis of gold nanoparticles for sensitive detection of aflatoxin B1 based on metal enhanced fluorescence
    Abhijith, Kunhitlu Subrahmanya
    Thakur, Munna Singh
    ANALYTICAL METHODS, 2012, 4 (12) : 4250 - 4256
  • [26] Construction of Down-conversion Fluorescence-Aptamer Immunochromatographic Strip for Rapid Detection of Aflatoxin B1
    Wang Z.
    Li L.
    Li D.
    Ai C.
    Ren L.
    Sun B.
    Shipin Kexue/Food Science, 2021, 42 (12): : 295 - 301
  • [27] A high selective immunochromatographic assay for rapid detection of aflatoxin B1
    Zhang, Daohong
    Li, Peiwu
    Yang, Yang
    Zhang, Qi
    Zhang, Wen
    Xiao, Zhi
    Ding, Xiaoxia
    TALANTA, 2011, 85 (01) : 736 - 742
  • [28] Pressure/colorimetric dual-readout immunochromatographic test strip for point-of-care testing of aflatoxin B1
    Jiang, Shan
    Zhang, Lvxia
    Li, Jizhou
    Ouyang, Hui
    Fu, Zhifeng
    TALANTA, 2021, 227
  • [29] A electrochemical immunosensor for the sensitive detection of aflatoxin B1
    Shi, L.
    Wang, Z. F.
    Wu, N.
    Yang, G. M.
    Chen, X. L.
    Liu, W.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 38 - 39
  • [30] Development of a Time-resolved Fluorescence Immunochromatographic Strip for the Simultaneous Detection of Aflatoxin B1 and Ochratoxin A in Corn Samples
    Lu D.
    Wang X.
    Yang J.
    Luo L.
    Xiao Z.
    Shipin Kexue/Food Science, 2022, 43 (02): : 346 - 354