Evaluation of implant alignment in navigated unicompartmental knee arthroplasty : a comparison of 2D and 3D imaging

被引:0
|
作者
Ishida, Kazunari [1 ]
Toda, Akihiko [1 ]
Shibanuma, Nao [1 ]
Matsumoto, Tomoyuki [1 ]
Kuroda, Ryosuke [1 ]
Kurosaka, Masahiro [1 ]
机构
[1] Kobe Kaisei Hosp, Dept Orthopaed Surg, Nada Ku, 3-11-15 Shinohara Kita, Kobe, Hyogo 6570068, Japan
来源
ACTA ORTHOPAEDICA BELGICA | 2015年 / 81卷 / 04期
关键词
unicompartmental knee arthroplasty; implant alignment; three-dimensional evaluation; radiographic evaluation; ROTATIONAL ALIGNMENT; ANTEROPOSTERIOR AXIS; FEMORAL COMPONENT; LIMB ALIGNMENT; KINEMATICS;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study aimed to compare two-dimensional (2D) and three-dimensional (3D) methods for evaluating implant alignment in navigated UKA. Nineteen UKAs in 18 subjects (7 men) were performed using an image-free navigation system. Coronal and sagittal implant alignments were assessed using radiographs (2D evaluation) and 3D image-matching software. The accuracy of 2D evaluation was compared with that of 3D evaluation. A deviation >3 degrees from the 3D evaluation was defined as an outlier. In the 2D evaluation, outliers for the femoral component were observed in both the coronal plane (6/19 subjects) and the sagittal plane (3/19 subjects). In UKA, assessment of the implant position might be misjudged because of the design of the implant, especially for the femoral component; 3D methods are ideal for assessment of implant alignment.
引用
收藏
页码:654 / 661
页数:8
相关论文
共 50 条
  • [1] Implant and Limb Alignment Outcomes for Conventional and Navigated Unicompartmental Knee Arthroplasty
    Valenzuela, Gustavo A.
    Jacobson, Nathan A.
    Geist, Derik J.
    Valenzuela, Richard G.
    Teitge, Robert A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 463 - 468
  • [2] Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty
    Van Duren, B. H.
    Pandit, H.
    Beard, D. J.
    Murray, D. W.
    Gill, H. S.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (03) : 356 - 363
  • [3] 3D printing and unicompartmental knee arthroplasty
    Jones, Gareth G.
    Clarke, Susannah
    Jaere, Martin
    Cobb, Justin
    EFORT OPEN REVIEWS, 2018, 3 (05) : 248 - 253
  • [4] Comparison of analog 2D and digital 3D preoperative templating for predicting implant size in total knee arthroplasty
    Kobayashi, Atsushi
    Ishii, Yoshinori
    Takeda, Mitsuhiro
    Noguchi, Hideo
    Higuchi, Hiroshi
    Toyabe, Sinichi
    COMPUTER AIDED SURGERY, 2012, 17 (02) : 96 - 101
  • [5] 2D versus 3D templating in total knee arthroplasty
    Ettinger, Max
    Claassen, Leif
    Paes, Peter
    Calliess, Tilman
    KNEE, 2016, 23 (01): : 149 - 151
  • [6] Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study
    Meijer, Marrigje F.
    Boerboom, Alexander L.
    Stevens, Martin
    Bulstra, Sjoerd K.
    Reininga, Inge H. F.
    PLOS ONE, 2014, 9 (09):
  • [7] 3D diffusion tensor imaging with 2D navigated turbo spin echo
    von Mengershausen, M
    Norris, DG
    Driesel, W
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (04) : 206 - 216
  • [8] 3D diffusion tensor imaging with 2D navigated turbo spin echo
    M. von Mengershausen
    D. G. Norris
    W. Driesel
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 206 - 216
  • [9] Evaluation of implant position and knee alignment after patient-specific unicompartmental knee arthroplasty
    Koeck, Franz Xaver
    Beckmann, Johannes
    Luring, Christian
    Rath, Bjoern
    Grifka, Joachim
    Basad, Erhan
    KNEE, 2011, 18 (05): : 294 - 299
  • [10] Comparison of 2D with 3D image alignment techniques for head and neck
    Sebastian, E. L.
    Kim, L. H.
    Wloch, J.
    Wu, Q.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S650 - S650