Identification of device malfunction in patients supported with the HeartMate XVE left ventricular assist system

被引:7
|
作者
Haft, Jonathan W.
Suzuki, Yoshi
Aaronson, Keith D.
Dyke, David B.
Wright, Susan
Poirier, Victor L.
Pagani, Francis D.
机构
[1] Univ Michigan Hlth Syst, Sect Cardiac Surg, Ann Arbor, MI 48109 USA
[2] Univ Michigan Hlth Syst, Div Cardiovasc Med, Ann Arbor, MI 48109 USA
[3] Thoratec Corp, Pleasanton, CA USA
关键词
D O I
10.1097/MAT.0b013e318033a6b0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Predicting end-of-life for left ventricular assist devices is important to determine timing of device removal. A retrospective analysis was performed on 46 patients undergoing implantation of the latest HeartMate XVE from July 1, 2003, through March 31, 2006. Devices were assessed by analysis of motor current waveforms and quantification of the titanium or copper particles within dust localized to the driveline vent filter by optical, polarized light, scanning electron microscopy, and energy dispersive x-ray spectroscopy. Assessments were performed monthly for patients supported >= 330 days or for unexpected device alarms. Thirty-one (67%) patients were supported for <330 days and 15 (33%) were supported for 2:330 days. No malfunctions occurred in patients supported <330 days. For patients supported 2:330 days, five had abnormal current waveforms or copper and titanium dust localized to the vent filter. One underwent urgent transplantation, three underwent device replacement (one death; two ongoing), and one is with ongoing support. Of the remaining 10 patients, seven underwent transplantation; two remain on device; and one died while on left ventricular assist device support. There were no unexpected device failures. Bearing wear of the HeartMate XVE is predictable by analysis of current waveforms or titanium and copper dust within the vent filter.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 50 条
  • [21] Device exchange from HeartMate II to HeartMate 3 left ventricular assist device
    Takeda, Koji
    Takayama, Hiroo
    Sanchez, Joseph
    Cevasco, Marisa
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Naka, Yoshifumi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 29 (03) : 430 - 433
  • [22] Outcomes in HeartMate 3 Left Ventricular Assist Device Patients Requiring Temporary Right Ventricular Assist Device Support
    Coyle, L.
    Pedersen, R.
    Gallagher, C.
    Graney, N.
    Kukla, L.
    Paliga, R.
    Chau, V.
    Macaluso, G.
    Pauwaa, S.
    Tatooles, A.
    Narang, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2024, 43 (04): : S414 - S414
  • [23] Hybrid ventricular assist device: Heartmate XVE LVAD and abiomed AB5000 RVAD
    Samuels, Louis E.
    Shemanski, Karen A.
    Casanova-Ghosh, Elena
    Hagan, Kevin
    Garwood, Phil
    Droogan, Christopher
    ASAIO JOURNAL, 2008, 54 (03) : 332 - 334
  • [24] Differential Impact on Post-transplant Outcomes between HeartMate XVE and HeartMate II Left Ventricular Assist Devices
    Ventura, P. A.
    Reid, B. B.
    Horne, B. D.
    Mason, N. O.
    Stoker, S.
    Alharethi, R.
    Budge, D.
    Rasmusson, B.
    Doty, J.
    Clayson, S. E.
    Kfoury, A. G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S99 - S99
  • [25] Exchange of a HeartMate II left ventricular assist device with a HeartMate 3 pump
    Hanke, Jasmin S.
    Haverich, Axel
    Schmitto, Jan D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2016, 35 (07): : 944 - 946
  • [26] The Effect of Continuous, Nonpulsatile Flow on Renal Function in Patients Supported by the HeartMate II Left Ventricular Assist Device
    Demirozu, Z. T.
    Radovancevic, R.
    Frazier, O. H.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S181 - S181
  • [27] The Incidence and Etiology of Gastrointestinal Bleeding in Patients Supported by the HeartMate II Continuous Flow Left Ventricular Assist Device
    Sharaiha, Reem
    Uriel, Nir
    Murray, Lindsay
    Yang, Jonathan
    Devaraj, Kalpana
    Colombo, Paulo
    Sims, Daniel
    Costello, Jose Gonzalez
    Takayama, Hiro
    Mancini, Donna
    Yoshifumi, Naka
    Jorde, Ulrich
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 : S407 - S408
  • [28] Low thromboembolic risk for patients with the Heartmate II left ventricular assist device
    John, Ranjit
    Kamdar, Forum
    Liao, Kenneth
    Colvin-Adams, Monica
    Miller, Leslie
    Joyce, Lyle
    Boyle, Andrew
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 136 (05): : 1318 - 1323
  • [29] Characterization of Gastrointestinal Bleeding in HeartMate II Left Ventricular Assist Device Patients
    Mason, N. O.
    Reid, B. B.
    Harmstan, G.
    Jones, J.
    Stoker, S.
    Budge, D.
    Alharethi, R.
    Thomsen, G.
    Clayson, S. E.
    Caine, W.
    Kfoury, A. G.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S175 - S175
  • [30] Warfarin Discontinuation in Patients with HeartMate3 Left Ventricular Assist Device
    Patel, P.
    Bhatia-Patel, S.
    Sykalo, C.
    Thigpen, C.
    Adams, A.
    Egolum, U.
    Howard, B.
    Gupta, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S461 - S461