Diagnostic performance of myocardial perfusion single-photon emission computed tomography with attenuation correction

被引:3
|
作者
Plachcinska, Anna [1 ]
Wlodarczyk, Michal [2 ]
Kovacevic-Kusmierek, Katarzyna [1 ]
Bienkiewicz, Malgorzata [1 ]
Drozdz, Jaroslaw [3 ]
Chizynski, Krzysztof [4 ]
Kasprzak, Jaroslaw D. [5 ]
Peruga, Jan Z. [5 ]
Kusmierek, Jacek [2 ]
机构
[1] Med Univ Lodz, Interfac Chair Med Imaging & Radiol, Dept Qual Control & Radiol Protect, Lodz, Poland
[2] Med Univ Lodz, Interfac Chair Med Imaging & Radiol, Dept Nucl Med, Lodz, Poland
[3] Med Univ Lodz, Chair Cardiol & Cardiac Surg, Dept Cardiol, Lodz, Poland
[4] Med Univ Lodz, Chair Cardiol & Cardiac Surg, Dept Intens Cardiac Therapy, Lodz, Poland
[5] Med Univ Lodz, Chair Cardiol, Dept Cardiol, Lodz, Poland
关键词
myocardial perfusion imaging; attenuation correction; diagnostic efficacy; 99mTc-MIBI SPECT; CORONARY-ARTERY-DISEASE; MULTICENTER CLINICAL-TRIAL; SPECT; ACCURACY; SCATTER; IMPACT;
D O I
10.5603/KP.a2015.0100
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial perfusion single-photon emission computed tomography (SPECT) is one of the basic tools used for the purpose of diagnosis of coronary artery disease (CAD), prognosis of its unfavourable consequences, and evaluation of therapy effectiveness. However, its efficacy is compromised by a relatively low specificity of detection of perfusion defects, which is attributed to attenuation of gamma rays inside the patient's body, causing artefacts erroneously taken for perfusion defects. It is expected that attenuation correction (AC) could eliminate such artefacts. Aim: To evaluate whether visual, semi-quantitative analysis of attenuation-corrected myocardial perfusion imaging provides an advantage over a non-corrected study. Methods: A retrospective study applying AC was performed in 107 patients who had coronary angiography within three months. Patients underwent a stress/rest Tc-99m methoxyisobutylisonitrile (MIBI, POLATOM) double day SPECT/CT myocardial perfusion imaging. Images were analysed by two experienced nuclear medicine specialists (a consensus) applying a visual semiquantitative method. Coronary angiography findings were used as a reference for the analysis of diagnostic performance of myocardial perfusion study protocols. Results: AC increased the specificity of detection of CAD in the whole group of patients from 63% to 86% (p = 0.0005), with a slight reduction in sensitivity (from 83% to 79%). The improved specificity was also noted in subgroups of male and female patients. Accuracy in the whole group of patients increased from 71% to 83% (p = 0.01). AC improved the specificity and accuracy of the method in the detection of perfusion defects in the right coronary artery (RCA) area from 73% to 88% (p = 0.005) and from 74% to 83% (p = 0.04), respectively, and the accuracy of the method in the left anterior descending (LAD) artery area from 79% to 87% (p = 0.043). It also reduced the number of ambiguous results of the study. Conclusions: AC improved the diagnostic performance of myocardial perfusion study in the detection of CAD and identification of critically stenosed LAD and RCA vessels, with enhanced comfort of study interpretation.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 50 条
  • [31] Cardiac single-photon emission tomography: Is attenuation correction enough?
    Brian F. Hutton
    European Journal of Nuclear Medicine, 1997, 24 (7) : 713 - 715
  • [32] Variation of Contrast Values for Myocardial Perfusion Imaging in Single-photon Emission Computed Tomography/Computed Tomography Hybrid Systems with Different Correction Methods
    Tantawy, Hazem M.
    Abdelhafez, Yasser G.
    Helal, Nadia L.
    Saad, Ibrahim E.
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [33] INCREMENTAL DIAGNOSTIC BENEFIT OF RESOLUTION RECOVERY SOFTWARE IN PATIENTS WITH EQUIVOCAL MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
    Qutub, Mohammed
    Dowsley, Taylor
    Ali, Iftikhar
    Wells, Glenn
    Ruddy, Terrence
    Chow, Benjamin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1051 - E1051
  • [34] Worldwide Diagnostic Reference Levels for Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Findings From INCAPS
    Hirschfeld, Cole B.
    Dondi, Maurizio
    Pascual, Thomas N. B.
    Mercuri, Mathew
    Vitola, Joao
    Karthikeyan, Ganesan
    Better, Nathan
    Mahmarian, John J.
    Bouyoucef, Salah E.
    Bom, Henry Hee-Seung
    Lele, Vikram
    Magboo, Vincent Peter C.
    Alexanderson, Erick
    Allam, Adel H.
    Al-Mallah, Mouaz H.
    Flotats, Albert
    Jerome, Scott
    Kaufmann, Philipp A.
    Luxenburg, Osnat
    Underwood, S. Richard
    Rehani, Madan M.
    Vassileva, Jenia
    Paez, Diana
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2021, 14 (03) : 657 - 665
  • [35] On single-photon emission computed tomography imaging based on an exact formula for the nonuniform attenuation correction
    Guillement, JP
    Jauberteau, F
    Kunyansky, L
    Novikov, R
    Trebossen, R
    INVERSE PROBLEMS, 2002, 18 (06) : L11 - L19
  • [36] Cardiac motion correction with a deep learning network for perfusion defect assessment in single-photon emission computed tomography myocardial perfusion imaging
    Zhang, Xirang
    Yang, Yongyi
    Pretorius, P. Hendrik
    Slomka, Piotr J.
    King, Michael A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2025, 43
  • [37] Low dose 16 slice chest computed tomography to correct for photon attenuation in myocardial perfusion single photon emission computed tomography
    Cheung, Y. W.
    Einstein, A. J.
    Bokhari, S.
    Jin, Z.
    Bhatia, K.
    Johnson, L.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S7 - S7
  • [38] Myocardial perfusion and function single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Daniel S. Berman
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    James R. Galt
    Ravi K. Garg
    Gary V. Heller
    Mark C. Hyun
    Lynne L. Johnson
    Benjamin D. McCallister
    Raymond Taillefer
    Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2006, 13 (6) : e97 - e120
  • [39] Myocardial perfusion and function: Single photon emission computed tomography
    Christopher L. Hansen
    Richard A. Goldstein
    Olakunle O. Akinboboye
    Daniel S. Berman
    Elias H. Botvinick
    Keith B. Churchwell
    C. David Cooke
    James R. Corbett
    S. James Cullom
    Seth T. Dahlberg
    Regina S. Druz
    Edward P. Ficaro
    James R. Galt
    Ravi K. Garg
    Guido Germano
    Gary V. Heller
    Milena J. Henzlova
    Mark C. Hyun
    Lynne L. Johnson
    April Mann
    Benjamin D. McCallister
    Robert A. Quaife
    Terrence D. Ruddy
    Senthil N. Sundaram
    Raymond Taillefer
    R. Parker Ward
    John J. Mahmarian
    Journal of Nuclear Cardiology, 2007, 14 (6) : e39 - e60
  • [40] Myocardial Perfusion Single-Photon Emission Computed Tomography (SPECT) Image Denoising: A Comparative Study
    Rahimian, Abdurrahim
    Etehadtavakol, Mahanaz
    Moslehi, Masoud
    Ng, Eddie Y. K.
    DIAGNOSTICS, 2023, 13 (04)