Influence of the cladding diameter of optical fiber on the simultaneous measurement of the refractive index and temperature of liquids using tilted fiber Bragg grating

被引:2
|
作者
Kameyama, Akihiro [1 ]
Katto, Masahito [2 ]
Yokotani, Atsushi [1 ]
机构
[1] Miyazaki Univ, Fac Engn, Miyazaki 8892192, Japan
[2] Miyazaki Univ, Ctr Collaborat Res & Community Cooperat, Miyazaki 8892192, Japan
关键词
D O I
10.7567/JJAP.55.068003
中图分类号
O59 [应用物理学];
学科分类号
摘要
We considered the influence of the core and cladding diameters on the simultaneous measurement of the refractive index and temperature of liquids using a tilted fiber Bragg grating (TFBG). When the cladding diameter of a TFBG was only reduced from 125 to 123 mu m, the calculated refractive index differed by 0.0068 from the expected value. When the core diameter was reduced from 9.6 to 7.8 mu m, the change was less than 0.0005. We found that equalization of cladding diameter is required to improve the precision of the simultaneous measurement of the refractive index and temperature of liquids. (C) 2016 The Japan Society of Applied Physics
引用
收藏
页数:3
相关论文
共 50 条
  • [31] Simultaneous measurement of refractive index, strain, and temperature based on a four-core fiber combined with a fiber Bragg grating
    Li, Chao
    Ning, Tigang
    Li, Jing
    Pei, Li
    Zhang, Chan
    Zhang, Chuanbiao
    Lin, Heng
    Wen, Xiaodong
    OPTICS AND LASER TECHNOLOGY, 2017, 90 : 179 - 184
  • [32] Demodulation of Tilted Fiber Bragg Grating Refractive Index Sensors with KLT
    Tosi, Daniele
    Shaimerdenova, Madina
    Bekmurzayeva, Aliya
    Sypabekova, Marzhan
    2017 IEEE SENSORS, 2017, : 723 - 725
  • [33] Cascaded tilted fiber Bragg grating for enhanced refractive index sensing
    姜碧强
    毕芷瑄
    王守恒
    席特立
    Kaiming Zhou
    Lin Zhang
    赵建林
    Chinese Physics B, 2018, 27 (11) : 261 - 265
  • [34] Cascaded tilted fiber Bragg grating for enhanced refractive index sensing
    Jiang, Biqiang
    Bi, Zhixuan
    Wang, Shouheng
    Xi, Teli
    Zhou, Kaiming
    Zhang, Lin
    Zhao, Jianlin
    CHINESE PHYSICS B, 2018, 27 (11)
  • [35] Simultaneous temperature and refractive index measurements using a 3° slanted multimode fiber Bragg grating
    Zhao, CL
    Yang, XF
    Demokan, MS
    Jin, W
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2006, 24 (02) : 879 - 883
  • [36] Simultaneous measurement of temperature and refractive index using a simplified modal interferometer composed of tilted long-period fiber grating and fiber bitaper
    Xue, Xiaolin
    Zhang, Weigang
    Zhang, Hao
    Gao, Shecheng
    Geng, Pengcheng
    Bai, Zhiyong
    Li, Jieliang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (06)
  • [37] Single tilted Bragg reflector fiber laser for simultaneous sensing of refractive index and temperature
    Wong, Allan C. L.
    Chung, W. H.
    Tam, Hwa-Yaw
    Lu, Chao
    OPTICS EXPRESS, 2011, 19 (02): : 409 - 414
  • [38] Cladding Mode Fitting-Assisted Automatic Refractive Index Demodulation Optical Fiber Sensor Probe Based on Tilted Fiber Bragg Grating and SPR
    Lin, Wenwei
    Huang, Weiying
    Liu, Yingying
    Chen, Xiaoyong
    Qu, Hang
    Hu, Xuehao
    SENSORS, 2022, 22 (08)
  • [39] Simultaneous measurement of strain and temperature using a reverse index fiber Bragg grating sensor
    Park, S. O.
    Jang, B. W.
    Lee, Y. G.
    Kim, C. G.
    Park, C. Y.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (03)
  • [40] An etched chirped fiber Bragg grating for measurement of refractive index and temperature pattern
    Shaimerdenova, M.
    Ayupova, T.
    Sypabekova, M.
    Korganbayev, S.
    Bekmurzayeva, A.
    Dukenbayev, K.
    Molardi, C.
    Tosi, D.
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820