Photothermal Cantilever Deflection Spectroscopy

被引:2
|
作者
Kim, Seonghwan [1 ]
Thundat, Thomas [2 ]
机构
[1] Univ Calgary, Dept Mech & Mfg Engn, Calgary, AB, Canada
[2] Univ Buffalo State Univ New York, Buffalo, NY USA
来源
ELECTROCHEMICAL SOCIETY INTERFACE | 2019年 / 28卷 / 03期
基金
加拿大自然科学与工程研究理事会;
关键词
SELECTIVE DETECTION; VAPOR MIXTURES;
D O I
10.1149/2.F07193IF
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Real-time chemical sensing based on PCDS has many advantages. It does not use any chemical receptors or interfaces for molecular recognition. The cantilever used in this technique has no surface functional groups. The target molecules are physisorbed from vapor phase onto the surface with no chemical interaction with the substrate. This approach overcomes the reproducibility problems encountered with immobilized receptor-based approaches. Samples can be deposited on the cantilever by placing a drop of solution and drying it in the ambient temperature. Since signal generation is based on the resonance excitation of various molecular bonds in the target molecule, the method is extremely selective. In a complex mixture, the resultant signal is a linear combination of molecular vibrations from various constituents and can be discerned using simple pattern recognition techniques. The PCDS combines the extreme high-thermal sensitivity of a bi-material microcantilever beam with the selectivity of mid-IR molecular spectroscopy. Our earlier results have shown mass sensitivity of 10 pg on the cantilever under ambient condition (corresponding to a few monolayers of analyte).14 The magnitude of the IR absorption-induced cantilever bending is proportional to the amount of analyte on the cantilever. This can be further quantified by measuring the resonance frequency of the cantilever (mass loading). PCDS is a simple technique that can offer high chemical selectivity. The demonstrated sensitivity and selectivity of this approach offers new possibilities for receptor-free sensing of a wide range of materials beyond what is currently possible using conventional techniques. These devices have the obvious advantages of requiring only sub-nanogram samples, quick detection times, and the potential to be inexpensive. It is possible to increase the sensitivity of photothermal cantilever deflection spectroscopy by optimizing the bi-material cantilever parameters as well as increasing the power of the illuminating IR source © ECS 2019.
引用
收藏
页码:55 / 57
页数:3
相关论文
共 50 条
  • [41] Trace explosive detection using photothermal deflection spectroscopy
    Krause, Adam R.
    Van Neste, Charles
    Senesac, Larry
    Thundat, Thomas
    Finot, Eric
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (09)
  • [42] COMPACT DESIGN FOR PHOTOTHERMAL DEFLECTION (MIRAGE) - SPECTROSCOPY AND IMAGING
    CHARBONNIER, F
    FOURNIER, D
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1986, 57 (06): : 1126 - 1128
  • [43] DISPERSIVE INFRARED PHOTOTHERMAL BEAM DEFLECTION SPECTROSCOPY OF SOLIDS
    DEBELLIS, AD
    LOW, MJD
    SPECTROSCOPY LETTERS, 1985, 18 (10) : 753 - 758
  • [44] HOMOGENEOUS IMMUNOASSAY USING PHOTOTHERMAL BEAM DEFLECTION SPECTROSCOPY
    SAKASHITA, H
    TOMITA, A
    UMEDA, Y
    NARUKAWA, H
    KISHIOKA, H
    KITAMORI, T
    SAWADA, T
    ANALYTICAL CHEMISTRY, 1995, 67 (07) : 1278 - 1282
  • [45] Pulsed Laser Photothermal Beam Deflection Spectroscopy of Silicon
    Petrovsky, A. N.
    Salnick, A. O.
    Zuev, V. V.
    Mukhin, D. O.
    Mekhtiev, M. M.
    LASER PHYSICS, 1991, 1 (03) : 279 - 288
  • [46] Time-averaged cantilever deflection in dynamic force spectroscopy
    Kawai, Shigeki
    Glatzel, Thilo
    Koch, Sascha
    Such, Bartosz
    Baratoff, Alexis
    Meyer, Ernst
    PHYSICAL REVIEW B, 2009, 80 (08)
  • [47] Bandedge absorption of GaAsN films measured by the photothermal deflection spectroscopy
    Beaudoin, M.
    Chan, I. C. W.
    Beaton, D.
    Elouneg-Jamroz, M.
    Tiedje, T.
    Whitwick, M.
    Young, E. C.
    Young, J. F.
    Zangenberg, N.
    JOURNAL OF CRYSTAL GROWTH, 2009, 311 (07) : 1662 - 1665
  • [48] OPTICAL AND THERMAL EVALUATION OF SEMICONDUCTOR BY DIFFERENTIAL PHOTOTHERMAL DEFLECTION SPECTROSCOPY
    HATA, T
    ISHIMARU, M
    HORITA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1992, 31 : 155 - 157
  • [49] COLLINEAR PHOTOTHERMAL DEFLECTION SPECTROSCOPY OF LIQUID SAMPLES AT VARYING TEMPERATURE
    SPEAR, JD
    SILVA, RJ
    KLUNDER, GL
    RUSSO, RE
    APPLIED SPECTROSCOPY, 1993, 47 (10) : 1580 - 1584
  • [50] AN APPROACH TO THE INFRARED STUDY OF MATERIALS BY PHOTOTHERMAL BEAM DEFLECTION SPECTROSCOPY
    LOW, MJD
    MORTERRA, C
    SEVERDIA, AG
    MATERIALS CHEMISTRY AND PHYSICS, 1984, 10 (06) : 519 - 528