In this study, permeability coefficient of frozen soil has been measured by transient pulse method for specimens in which ice lenses did not exist by applying axis stress more than ice pressure calculated by generalized Clausius-Clapeyron equation. The applicability of the transient pulse method for frozen soil was examined by comparing the previous study conducted by authors. It is found that the permeability coefficient has a dependency on temperature and changes drastically over the tested temperature range. These tendencies of the permeability coefficient under negative temperature were similar to the permeability coefficient obtained by the constant head permeability test. Therefore, it is concluded that transient pulse method can be available to measure the permeability coefficient of frozen soil.
引用
收藏
页码:71 / 78
页数:8
相关论文
共 50 条
  • [1] Application of transient pulse method to permeability measurement for clay
    Kato M.
    Nara Y.
    Okazaki Y.
    Kohno M.
    Sato T.
    Sato T.
    Takahashi M.
    Zairyo/Journal of the Society of Materials Science, Japan, 2018, 67 (03): : 318 - 323
  • [2] A transient pressure pulse method for the measurement of permeability of a cement grout
    Selvadurai, APS
    Carnaffan, P
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (03) : 489 - 502
  • [3] Soil air permeability measurement with a transient pressure buildup method
    Cho, JS
    Ellett, D
    HAZARDOUS WASTE & HAZARDOUS MATERIALS, 1995, 12 (04): : 365 - 371
  • [4] Comparison between steady state method and pulse transient method for coal permeability measurement
    Qiu, Yongkai
    Li, Zhiping
    Hao, Shiyan
    2017 INTERNATIONAL SYMPOSIUM ON RESOURCE EXPLORATION AND ENVIRONMENTAL SCIENCE (REES 2017), 2017, 64
  • [5] The Design Criteria of Storage-Adjustable Transient Pulse Method for Large Range Permeability Measurement
    Wang, Ying
    Li, X. C.
    Wei, N.
    Xiao, Wenlian
    2011 INTERNATIONAL CONFERENCE OF ENVIRONMENTAL SCIENCE AND ENGINEERING, VOL 12, PT B, 2012, 12 : 871 - 877
  • [6] Application of the Transient Pulse Method to Measure Clay Permeability
    Kato, Masaji
    Nara, Yoshitaka
    Okazaki, Yuki
    Kohno, Masanori
    Sato, Toshinori
    Sato, Tsutomu
    Takahashi, Manabu
    MATERIALS TRANSACTIONS, 2018, 59 (09) : 1427 - 1432
  • [7] The Design Criteria of Storage-Adjustable Transient Pulse Method for Large Range Permeability Measurement
    Wang, Ying
    Li, X. C.
    Wei, N.
    Xiao, Wenlian
    2011 INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND NEURAL COMPUTING (FSNC 2011), VOL II, 2011, : 352 - 355
  • [8] Transient methods for the measurement of thermophysical properties:: The pulse transient method
    Kubicár, L
    Bohác, V
    Vretenár, V
    HIGH TEMPERATURES-HIGH PRESSURES, 2002, 34 (05) : 505 - 514
  • [9] ERROR ANALYSIS OF TRANSIENT METHOD FOR ROCK PERMEABILITY MEASUREMENT
    Ni, Xiao-Yan
    Gong, Peng
    Du, Bin
    Yang, Ning
    Deng, Peng
    THERMAL SCIENCE, 2024, 28 (2A): : 1021 - 1027
  • [10] ERROR ANALYSIS OF TRANSIENT METHOD FOR ROCK PERMEABILITY MEASUREMENT
    Ni, Xiao-Yan
    Gong, Peng
    Du, Bin
    Yang, Ning
    Deng, Peng
    THERMAL SCIENCE, 2024, 28 (02): : 1021 - 1027