Application of transient pulse method to permeability measurement for clay

被引:0
|
作者
Kato M. [1 ]
Nara Y. [2 ]
Okazaki Y. [3 ]
Kohno M. [3 ]
Sato T. [4 ]
Sato T. [4 ]
Takahashi M. [5 ]
机构
[1] Faculty of Eng., Hokkaido Univ., Kita-ku, Sapporo
[2] Graduate School of Eng., Kyoto Univ., Nishikyo-ku, Kyoto
[3] Graduate School of Eng., Tottori Univ., Koyama-Minami, Tottori
[4] Horonobe Underground Res. Center, Japan Atomic Energy Agency (JAEA), Horonobe, Hokkaido
[5] Res. Inst. of Earthquake and Volcano Geology, National Inst. of Adv. Industrial Sci. and Technol. (AIST), Higashi, Tsukuba
基金
日本学术振兴会;
关键词
Clay; Granite; Hydraulic conductivity; Permeability test; Transient pulse method;
D O I
10.2472/jsms.67.318
中图分类号
学科分类号
摘要
To ensure the safe geological disposal of radioactive wastes, it is important to determine the permeability of clays. The transient pulse test is suitable to apply to the low permeability materials, because it takes relatively short term to determine the permeability. Usually we increase the upstream pore pressure in the measurement with the transient pulse test. However, it is impossible to determine the permeability of clay in this procedure because of the increase of pore pressure. Therefore, the transient pulse test has never been applied to the determination of permeability of clays. In this study, we tried to apply the transient pulse test to a clay obtained in Mizunami Underground Research Laboratory to determine the permeability with decreasing the downstream pore pressure. It was clarified that the transient pulse test with decreasing downstream pore pressure is appropriate from the measurement of granite. It was shown that the permeability of a clay was determined by the transient pulse test with decreasing the downstream pore pressure, which agreed with the permeability determined from the falling head test. The measurement time of the transient pulse test is much shorter than that of the falling head test. It is concluded that the transient pulse test is appropriate for the determination of the permeability of clays. © 2018 The Society of Materials Science, Japan.
引用
收藏
页码:318 / 323
页数:5
相关论文
共 50 条
  • [1] Application of the Transient Pulse Method to Measure Clay Permeability
    Kato, Masaji
    Nara, Yoshitaka
    Okazaki, Yuki
    Kohno, Masanori
    Sato, Toshinori
    Sato, Tsutomu
    Takahashi, Manabu
    MATERIALS TRANSACTIONS, 2018, 59 (09) : 1427 - 1432
  • [2] Measurement for Permeability of Frozen Soil by Transient Pulse Method
    Tokoro, Tetsuya
    Ishikawa, Tatsuya
    TRANSPORTATION SOIL ENGINEERING IN COLD REGIONS, VOL 1, 2020, 49 : 71 - 78
  • [3] A transient pressure pulse method for the measurement of permeability of a cement grout
    Selvadurai, APS
    Carnaffan, P
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 1997, 24 (03) : 489 - 502
  • [4] Comparison between steady state method and pulse transient method for coal permeability measurement
    Qiu, Yongkai
    Li, Zhiping
    Hao, Shiyan
    2017 INTERNATIONAL SYMPOSIUM ON RESOURCE EXPLORATION AND ENVIRONMENTAL SCIENCE (REES 2017), 2017, 64
  • [5] The Design Criteria of Storage-Adjustable Transient Pulse Method for Large Range Permeability Measurement
    Wang, Ying
    Li, X. C.
    Wei, N.
    Xiao, Wenlian
    2011 INTERNATIONAL CONFERENCE OF ENVIRONMENTAL SCIENCE AND ENGINEERING, VOL 12, PT B, 2012, 12 : 871 - 877
  • [6] The Design Criteria of Storage-Adjustable Transient Pulse Method for Large Range Permeability Measurement
    Wang, Ying
    Li, X. C.
    Wei, N.
    Xiao, Wenlian
    2011 INTERNATIONAL CONFERENCE ON FUZZY SYSTEMS AND NEURAL COMPUTING (FSNC 2011), VOL II, 2011, : 352 - 355
  • [7] Measurement of Gas Permeability in Geosynthetic Clay Liners in Transient Flow Mode
    Pitanga, Heraldo Nunes
    Pierson, Patrick
    Vilar, Orencio Monje
    GEOTECHNICAL TESTING JOURNAL, 2011, 34 (01): : 27 - 33
  • [8] Transient methods for the measurement of thermophysical properties:: The pulse transient method
    Kubicár, L
    Bohác, V
    Vretenár, V
    HIGH TEMPERATURES-HIGH PRESSURES, 2002, 34 (05) : 505 - 514
  • [9] ERROR ANALYSIS OF TRANSIENT METHOD FOR ROCK PERMEABILITY MEASUREMENT
    Ni, Xiao-Yan
    Gong, Peng
    Du, Bin
    Yang, Ning
    Deng, Peng
    THERMAL SCIENCE, 2024, 28 (2A): : 1021 - 1027
  • [10] ERROR ANALYSIS OF TRANSIENT METHOD FOR ROCK PERMEABILITY MEASUREMENT
    Ni, Xiao-Yan
    Gong, Peng
    Du, Bin
    Yang, Ning
    Deng, Peng
    THERMAL SCIENCE, 2024, 28 (02): : 1021 - 1027